Chapter 8 Basic Setting

 

Table 10 Basic Setting > System Info (continued)

 

LABEL

DESCRIPTION

 

Threshold

This field displays the upper temperature limit at this sensor.

 

 

 

 

Status

This field displays Normal for temperatures below the threshold and Error

 

 

for those above.

 

 

 

 

Fan Speed

A properly functioning fan is an essential component (along with a

 

(RPM)

sufficiently ventilated, cool operating environment) in order for the device

 

 

to stay within the temperature threshold. Each fan has a sensor that is

 

 

capable of detecting and reporting if the fan speed falls below the

 

 

threshold shown.

 

 

 

 

Current

This field displays this fan's current speed in Revolutions Per Minute (RPM).

 

 

 

 

MAX

This field displays this fan's maximum speed measured in RPM.

 

 

 

 

MIN

This field displays this fan's minimum speed measured in RPM. “<41" is

 

 

displayed for speeds too small to measure (under 2000 RPM).

 

 

 

 

Threshold

This field displays the minimum speed at which a normal fan should work.

 

 

 

 

Status

Normal indicates that this fan is functioning above the minimum speed.

 

 

Error indicates that this fan is functioning below the minimum speed.

 

 

 

 

Voltage (V)

The power supply for each voltage has a sensor that is capable of

 

 

detecting and reporting if the voltage falls out of the tolerance range.

 

 

 

 

Current

This is the current voltage reading.

 

 

 

 

MAX

This field displays the maximum voltage measured at this point.

 

 

 

 

MIN

This field displays the minimum voltage measured at this point.

 

 

 

 

Threshold

This field displays the percentage tolerance of the voltage with which the

 

 

Switch still works.

 

 

 

 

Status

Normal indicates that the voltage is within an acceptable operating range

 

 

at this point; otherwise Error is displayed.

 

 

 

 

103

XGS-4526/4528F/4728F User’s Guide