Chapter 14 Quality of Service (QoS)

The following table describes the labels in this screen.

Table 66 QoS > Policer Setup: Edit

LABEL

DESCRIPTION

Enable

Select this to have the P-870HN-51D pass, drop or mark packets

 

that exceed the committed rate and/or committed burst size

 

specified in this screen.

 

 

Meter Type

Select the method that the P-870HN-51D uses for determining which

 

packets to pass, drop or mark (DSCP). Choices are: Simple Token

 

Bucket, Single Rate Three Color Meter and Two Rate Three

 

Color Meter. Refer to Section 14.8.2 on page 186 for information on

 

these meter types.

 

 

Committed

Enter the maximum committed rate for the specified class/es.

Rate

 

 

 

Committed

Enter the maximum committed burst size for the specified class/es.

Burst Size

 

 

 

Conforming

Select the action that the P-870HN-51D applies to packets that

Action

conform to the meter type selected. Choices are Pass, Drop and

 

DSCP mark.

 

Pass - the packet is allowed to flow to its destination.

 

Drop - the packet is discarded.

 

DSCP mark - the packet is given a DSCP mark and processed

 

accordingly. See Section 14.8.1 on page 185 for information on

 

DSCP mark.

 

 

Non-

Select the action that the P-870HN-51D applies to packets that do not

comforming

conform to the meter type selected. Choices are Pass, Drop and

Action

DSCP mark.

 

 

Pass - the packet is allowed to flow to its destination.

 

Drop - the packet is discarded.

 

DSCP mark - the packet is given a DSCP mark and processed

 

accordingly. See Section 14.8.1 on page 185 for information on

 

DSCP mark.

 

 

Regularted

Use the Add and Remove buttons to select or deselect classes to

Classes Member

which the policy applies.

Setting

 

 

 

Available Class

This shows the available classes.

 

 

Selected Class

This shows classes to which the policy applies.

 

 

Back

Click Back to return to the previous screen without saving.

 

 

Apply

Click Apply to save your changes back to the P-870HN-51D.

 

 

Cancel

Click Cancel to begin configuring this screen afresh.

 

 

182

 