Chapter 4 Status Screens

Table 8 Status > VDSL Statistics (continued)

LABEL DESCRIPTION

VDSL Port Details

These are the maximum Upstream and Downstream transfer rates for the ports that belong to this profile. Upstream traffic refers to traffic from the P-870HN-51D to the Central Organization Equipment (COE). Downstream traffic refers to traffic from the COE to the P-870HN-51D.

Line Rate

This indicates the maximum upstream/downstream net data rate

 

currently attainable on this line.

 

 

Actual Net Line

This indicates the actual upstream/downstream data transmission rate.

Rate

 

 

 

Trellis Coding

Trellis coding is a modulation scheme which allows highly efficient

 

transmission of information over band-limited channels such as

 

telephone lines. N/A means Trellis coding is disabled or not used on the

 

P-870HN-51D.

 

 

SNR Margin

This indicates the upstream/downstream SNR margin.

 

 

Actual Delay

This indicates the actual upstream/downstream transmission delay (in

 

milliseconds).

 

 

Transmit

This indicates the upstream/downstream transmission power of the line.

Power

 

 

 

Receive Power

This indicates the upstream/downstream receiving power of the line.

 

 

Actual INP

This indicates the actual impulse noise protection (INP).

 

 

Total

This indicates the upstream/downstream attenuation.

Attenuation

 

 

 

Attainable Net

This indicates the maximum upstream/downstream net data rate

Data Rate

currently attainable on this line.

 

 

VDSL Band

The fields in this section indicate the status for upstream bands 0, 1, 2, 3

Status

(U0, U1, U2, U3) and downstream bands 1, 2, 3 (D1, D2, D3).

 

 

Line

This indicates the line attenuation status for each upstream and

Attenuation

downstream band. NA displays when the band is not used.

 

 

Signal

This indicates the signal attenuation status for each upstream and

Attenuation

downstream band. NA displays when the band is not used.

 

 

SNR Margin

This indicates the signal to noise ratio for each upstream and

 

downstream band. NA displays when the band is not used.

 

 

Transmit

This indicates the line transmission power for each upstream and

Power

downstream band. NA displays when the band is not used.

 

 

Since Link time

This indicates VDSL performance information recorded since the

 

connection is up.

 

 

FEC

This indicates the number of Forward Error Correction Seconds (FECs)

 

failures since the last reset.

 

 

CRC

This indicates the number of CRC (Cyclic Redundant Check) error(s)

 

since the last reset.

 

 

ES

This indicates the number of port endpoint errored seconds (ESs) since

 

the last reset.

 

 

SES

This indicates the number of port endpoint severely errored seconds

 

(SESs) since the last reset.

 

 

 

63

P-870HN-51D User’s Guide