Chapter 23 Diagnostic
•Loopback test - checks if the MEP port receives its Loop Back Response (LBR) from its target after it sends the Loop Back Message (LBM). If no response is received, there might be a connectivity fault between them.
•Link trace test - provides additional connectivity fault analysis to get more information on where the fault is. If an MEP port does not respond to the source MEP, this may indicate a fault. Administrators can take further action to check and resume services from the fault according to the line connectivity status report.
23.3The General Diagnostic Screen
Click Maintenance > Diagnostic to open the screen shown next. Ping and traceroute help check availability of remote hosts and also help troubleshoot network or Internet connections.
Figure 138 Maintenance > Diagnostic > General
The following table describes the fields in this screen.
Table 90 Maintenance > Diagnostic > General
LABEL | DESCRIPTION |
TCP/IP | Type the IP address of a computer that you want to ping in order to test a |
Address | connection or trace the route packets take to. |
|
|
Ping | Click this button to ping the IP address that you entered. |
|
|
Traceoute | Click this button to perform the traceroute function. This determines the |
| path a packet takes to the specified host. |
|
|