Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.

First 8 Hours

• Change engine oil

Every 8 Hours or Daily

Clean debris

Check engine oil level

Every 25 Hours or Yearly

• Service engine air cleaner pre-filter1

Every 50 Hours or Yearly

• Inspect muffler and spark arrester

Every 100 Hours or Yearly

Service engine air cleaner paper filter1

Service fuel filter

Service spark plugs

Change engine oil and filter2

Clean cooling system1

Every 250 Hours or Yearly

• Check valve clearance

1Service more often under dirty or dusty conditions.

2Change engine oil every 50 hours if you are using your generator under heavy load, or in extremely hot weather.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See any authorized dealer for service.

The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain your generator.

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual.

However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

NOTE: DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Cleaning

Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Keep the area around and behind the muffler free from any combustible debris. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:

• Use a damp cloth to wipe exterior surfaces clean.

NOTICE Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.

WARNING Battery posts, terminals and related accessories contain lead and lead compounds - chemicals known to the State of California to cause cancer and reproductive harm. Wash hands after handling.

18

BRIGGSandSTRATTON.COM

Image 18
Contents Operator’s Manual Manual No GS Revision a 02/25/2009Engine Where to Find UsGenerator Date PurchasedTable of Contents Safety Symbols and Meanings Operator SafetyImportant Safety Information Equipment DescriptionHydrogen gas during recharging Monoxide, an odorless, colorless, poison gasNausea, fainting or death Fire or explosion can cause severe burns or deathFuel tank causing a fire When Testing for Engine SparkExcessively low speeds impose a heavy load Shipment Contents AssemblyInstall Wheel Kit Unpack GeneratorAttach Negative Battery Cable To installTip generator so that engine end is up Fuel must meet these requirements Add Engine OilAdd Fuel High AltitudeGenerator Location Connecting to a Building’s Electrical SystemSystem Ground Special RequirementsFeatures and Controls Recoil Starter Used to start the engine manuallyCord Sets and Receptacles Nema L14-30Nema L5-30 Test Gfci Circuit Breaker Ground Fault ProtectionBattery Charger Test your Gfci circuit breaker every month, as followsConnecting Electrical Loads OperationStarting the Engine Operating Automatic Idle Control Charging a Battery Stopping the Engine Oil Pressure ShutdownCold Weather Operation Creating a Temporary Cold Weather ShelterBuilding a Cold Weather Shelter Don’t Overload Generator Wattage Reference GuideGenerator Maintenance MaintenanceMaintenance Schedule Battery MaintenanceOil Recommendations Fuel Valve MaintenanceEngine Maintenance Checking Oil LevelService Spark Plugs Service Air CleanerTo service the air cleaner, follow these steps Changing Engine Oil and FilterCarburetor Adjustment Clean and inspect the spark arrester as followsClean Cooling System Inspect Muffler and Spark ArresterLong Term Storage Instructions StorageGenerator Storage Change Engine OilTroubleshooting BRIGGSandSTRATTON.COM Page Owner’s Warranty Responsibilities Your Warranty Rights And ObligationsManufacturer’s Warranty Coverage Briggs & Stratton Emissions Control Warranty ProvisionsIntermediate Warranty on emissions-related parts is as followsModerate ExtendedLimited Warranty Reserved Product Specifications Common Service Parts800 Manual del Operario Motor Dónde encontrarnosGenerador Fecha de compraMontaje Resolución de problemas GarantíasSeguridad de operario Controles y característicasInformación importante de seguridad Seguridad de operarioDescripción del equipo Símbolos sobre la seguridad y significadosNo arranque el motor sin la bujía instalada Cuando Anada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Máquina Generador Cuando Pruebe LA Bujía DEL MotorNo modifique al generador en ninguna forma Contenido de la caja MontajeDesembalaje del generador Instale el juego de ruedasConecte el cable negativo de la batería Suba el asas e inserte su pasador para mover el generadorPara instalar El combustible debe reunir los siguientes requisitos Agregar aceite al motorAgregue combustible Gran altitudUbicación del generador Tierra del sistemaConexión al sistema eléctrico de un edificio Requisitos especialesTomacorriente con Dispositivo de Seguridad de Controles y característicasAmperios, monofásica de 60 Hz Culatazo el Principio Usó para comenzar motor manualmenteJuegos de cordones y enchufes conectores Juego de Cable de 3 AlambresNeutro Cargado Tierra Verde Protección contra fallos de conexión a tierra Cargador de bateríaOperando Encienda el motorSi el motor no arranca, repita los pasos desde 4 hasta Funcionamiento del control automático de marcha en vacío Conexión de cargas eléctricasParada del motor Parada por falta de presión de aceiteCarga de la bateria Operación durante un clima fríoLimpie los terminales de la batería si es necesario Page Ejemplo No sobrecargar el generadorCapacidad Control de la energíaMantenimiento del generador MantenimientoPlan de mantenimiento Mantenimiento de la bateríaMantenimiento de la válvula de combustible Mantenimiento del motorColoque el tapón de vaciado y apriételo bien Instale el varilla de medición, apriete firmementeCambio de aceite del motor y filtro Quite la varilla de nivel de aceiteLimpie e inspeccione el apagachispas de la siguiente manera Servicio del bujíaInspeccione el silenciador y la pantalla apagachispas Sistema de refrigeración de aireAlmacenamiento para periodos prolongados AlmacenamientoGenerador Cambio de AceiteResolución de problemas Problemo Causa AccionResponsabilidades de la garantía del propietario GarantíasCobertura de la garantía del fabricante Conectores y unidades Duración de la coberturaBRIGGSandSTRATTON.COM Garantía Limitada Especificaciones del producto Servicio común despideManuel d’utilisation Moteur Où nous trouverGénératrice Date d’achatAssemblage Fonctions et commandesSécurité de l’opérateur OpérationDescription de l équipement Symboles de sécurité et leur significationSécurité de l’opérateur Renseignements importants de sécuritéLors DU Démarrage DE Léquipement ExplosivesLors DE Lajout OU DE LA Vidange DU Carburant Lorsque Léquipement FonctionneLorsque Vous Réglez OU Réparez Votre Génératrice Avertissement Le génératrice produit une tension élevéeNE Touchez PAS les fils dénudés ou les boîtiers Lors DE Tests Dallumage DU MoteurDéballez la génératrice Installe la roue la trousseAssemblage Contenu de l’expéditionReplacez la génératrice à sa positon normale sur les roues InstallationRaccordez le câble de retour de la batterie Rattachez la vis au terminal négative de pile et serrez’essence satisfait les exigences suivantes Ajoutez de lhuile à moteurAjoutez de lessence Avis Évitez d’endommager le génératriceExigences spéciales Emplacement de la génératriceMise à la terre du système Dégagement de la génératriceFonctions et commandes Chargeur à tampon de batterie Utilisez la prise du chargeurCordons et prises Et/ou des dommages matérielsMise à lessai du disjoncteur Gfci Protection contre les fuites de terreChargeur de batterie Pendant le fonctionnement de la génératriceOpération Démarrage du moteurFonctionnement du contrôle automatique du ralenti Branchement des charges électriquesArrêt du moteur Arrêt du moteur en cas de bas niveau d’huileSi nécessaire, nettoyer les bornes de la batterie Recharge d’une batterieFonctionnement par temps froid Protégez lunité contre les intempériesCréation d’un abri temporaire pour les temps froids Création d’un abri pour les temps froidsVent Ne pas surchargez générateur ExempleGestion de la consommation Entretien Calendrier dentretienEntretien de génératrice Entretien de la vanne de combustible Huile Recommandations relatives à l’huileEntretien de la batterie Entretien du moteurChangement d’huile à moteur et de filtre Vérification du niveau dhuileAjout d’huile Secondes pour laisser couler lhuileEntretien de la bougies dallumage Entretien du filtre à airDécrochez les verrous a des deux côtés du Inspectez le silencieux et l’écran pare-étincellesNettoyer le système de refroidissement Nettoyez et inspectez le pare-étincelles comme suitRemettez l’écran en place et fixez-le avec quatre vis Vérifier le jeu des soupapesChangement de lhuile EntreposageEntreposage de la génératrice Autres idées de remisageDépannage Couverture de garantie du fabricant GarantiesVos droits et obligations relatifs à la garantie Pièces garantiesCatégorie B = 250 heures Catégorie a = 500 heures Garantie Limitée Réservé Caractéristiques du produit Pièces d’entretien courant