Briggs & Stratton 040220A manual Fuel Consumption, Temporary Manometer Installed

Page 14

INSTALLATION

The Home Generator System unit has been factory set to run on natural gas. If you need to change from natural gas to LP gas, the unit will need to be reconfigured, as described in Fuel System Selection.

It is recommended that the fuel connection incorporate the following components:

A manual fuel shut-off valve located in the interior of the building.

A manual fuel shut-off valve located outside the building, just before the generator unit.

Where the formation of hydrates or ice is known to occur, piping should be protected against freezing. The termination of hard piping should include a sediment trap where condensate is not likely to freeze.

A manometer port should be provided.

The manometer port permits temporary installation of a manometer (Figure 5), to ensure that the engine receives the correct fuel pressure to operate efficiently throughout its operating range.

Figure 5 — Temporary Manometer Installed

When the initial test runs are completed, the manometer is removed and the port is plugged. A typical final fuel connection assembly is shown in Figure 6.

Figure 6 — Completed Fuel Connections

From Fuel

Supply Line

To Home Standby

Generator

Fuel Consumption

See Figure 7 for estimated fuel supply requirements at half and full load for both natural gas and LP vapor.

Figure 7 — Fuel Supply Requirements

Natural Gas

LP Vapor

 

 

 

 

1/2 Load

Full Load

1/2 Load

Full Load

 

 

 

 

80 C

137 C

33 C

56 C

 

 

 

 

80,000 B

137,000 B

82,500 B

140,000 B

 

 

 

 

C = Cubic feet per hour

B = BTU’s per hour

NOTE: A digital manometer, P/N 19495, is available at your local Briggs & Stratton service center.

14

Image 14
Contents Rated Watts Home Generator System Table of Contents Engine exhaust from this product contains Important Safety InstructionsHazard Symbols and Meanings Certain components in this product and relatedSafety Rules Installing the 15A fuse could cause the engine to start Control Panel see BatteryKnow Your Home Standby Generator Know Your Control Panel AUTO/OFF/MANUALIntroduction Installer ResponsibilitiesInstallation Assistance Customer ResponsibilitiesInstallation Procedures Owner OrientationGenerator Clearances Lifting the GeneratorHome Standby Generator Location General Location GuidelinesDevice Running Watts Essential CircuitsEssential Circuit Selection Disconnect Box Mounting Guidelines Fuel Inlet DimensionsRemovable Roof and Access Door Gaseous Fuel System Do not light a cigarette or smokeTemporary Manometer Installed Fuel Consumption10ft Fuel Pipe Sizing10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ft Physical Properties Propane Natural Gas Fuel Comparison ChartWithdrawal Rate 32F 20F 10F 30F 40F Wire Connections Before Initial START-UPBattery posts, terminals and related accessories contain Battery ConnectionCharging the Battery Servicing the BatteryAutomatic Operation Sequence Fuel System SelectionInitial START-UP no Load Fuel Supply SystemEngine Cool-down Timer Setting Exercise TimerInstallation Inspection To perform the Set Exercise procedureAutomatic Operation SpecificationsFault Detection System Checking Automatic OperationNo LED Discharged Battery Fault DescriptionReset Fault Detection System Low Oil PressureChanging Oil Generator MaintenanceChanging Engine Oil and Filter Changing Oil FilterStorage To Clean the GeneratorWhen Calling the Factory Down when loads are connected TroubleshootingProblem Cause Correction AvailableSchematic Wiring Diagram Page Limited Warranty Tabla DE Contenido Sensor de Excitación de Tensión de la CompañíaDeterminados componentes en este producto y los AdvertenciaSímbolos de Peligro y Significados Gases Tóxicos Manual de OperarioLos generadores producen un voltaje muy poderoso Precaución Instala el fusible se puede producir el arranque del motorFiltro de Aceite Salida del Escape Conozca SU Generador DE ReservaEtiqueta del Motor Manguera de Drenaje de Aceite Etiqueta deConozca EL Panel DE Control DisyuntorResponsabilidades DEL Instalador Conserve Estas InstruccionesIntroducción Responsabilidades DEL ClienteProcedimientos DE Instalación Distancias Desde el Generador Elevación del GeneradorUbicación del Generador de Reserva Pautas Generales para la Ubicación del GeneradorDispositivo Vatiaje de Circuitos FundamentalesSelección de los Circuitos Fundamentales Techo y Puerta de Acceso Desmontables Dimensiones de la Entrada de CombustibleDirectrices de Montaje del Cuadro de Desconexión Sistema DE Combustible Gaseoso Gas Natural Vapor de PL Consumo de CombustibleAl generador de Reserva Propano Líquido PL peso específico = Dimensiones de la Cañería de CombustibleGas Natural peso específico = Tasa de consumo 32F 20F 10F 30F 40F Cuadro de Comparación de CombustiblesPropiedades físicas Propano Gas natural Conexiones DE Cables Antes DEL Arranque InicialFije el interruptor AUTO/OFF/MANUAL en la posición Auto Conexión de la BateríaInstale el fusible de 15 Amperios en el panel de control Servicio la BateríaSecuencia DE Operación Automática Selección DEL Sistema DE CombustibleArranque Inicial SIN Carga Sistema de Suministro de CombustibleInspección Posterior a LA Instalación Temporizador de enfriamiento del motorSistema DE Detección DE Fallas EspecificacionesOperación Automática Verificación de la Operación AutomáticaLas patillas de las baterías, los terminales y los Cambio del Filtro de Aceite Mantenimiento DEL GeneradorCambio del Aceite del Motor y del Filtro Cambio del AceiteSi Llama a la Fábrica AlmacenamientoPara Limpiar el Generador Reparacion DE Averias Notas Garantía Limitada Table DES Matières Avertissement Symboles de Danger et MoyensVeuillez Conserver CES Instructions NE touchez PAS les fils dénudés ou les boîtiers Avis FAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTE Filtre à Air Et Jauge dHuile Filtre à lHuile15 Ampères FAMILIARISEZ-VOUS Avec LE Tableau DE CommandeFusible de DisjoncteurConservez CES Instructions Responsabilités DE LinstallateurAide À Linstallation IntroductionProcédures Dinstallation Conseils AU PropriétaireSoulèvement de la Génératrice Emplacement du Génératrice d’état d’AttenteDirectives Générales Concernant lEmplacement Dégagement Autour de la GénératriceAppareil Watts Circuits EssentielsSélection des Circuits Essentiels Toit Amovible et Porte dAccès Dimensions de lOrifice dAdmission du CombustibleDirectives dAssemblage du Boîtier de Débranchement LE Système DE Combustible Gazeux Vers le génératrice ’état d’attente Consommation de CombustibleIl faudrait inclure une sortie pour manomètre Gas Naturel Vapeur PLGrosseur du Tuyau de Combustible Gaz de Pétrole Liquéfié GPL densité = 1,5032F 20F 10F 30F 40F Charte de Comparaison des CombustiblesPropriétés physiques Propane Gaz naturel 12,2 C 17,8 C 23,3 C 34,4 C 40 CRaccords DE Fils Avant LE Démarrage InitialRéglez linterrupteur AUTO/OFF/MANUAL sur Auto Branchement de la BatterieRechargez la Batterie Entretien de la BatterieSystème dAlimentation en Combustible Sélection DU Système DE CombustibleDémarrage Initial Sans Charge Réglez linterrupteur AUTO/OFF/MANUAL sur ManualRéglage DE LA Minuterie DU Cycle Dexercice Vérification InstallationCapteur de Prise en Charge de la Tension de Service Minuterie de Refroidissement du MoteurSystème DE Détection DES Pannes CaractéristiquesFonctionnement Automatique Entretien du SystèmeAucun DEL Batterie déchargée Nombre de Clignotements Du VoyantRéarmement du Système de Détection des Pannes Faible Pression dHuileVidange de lHuile Entretien DU GénérateurChangement dHuile à Moteur et de Filtre Changement du filtre à huileCommunications avec le Fabricant RemisagePour Nettoyer le Générateur Dépannage Garantie Limitée

040220A specifications

Briggs & Stratton is renowned for its high-performance engines, and the Briggs & Stratton 040220A is no exception. This powerful engine is designed to deliver reliable performance for a variety of outdoor applications, including lawn mowers, garden tractors, and other small machinery. One of the standout features of the 040220A is its sturdy construction. It is built with high-quality materials, ensuring durability and longevity, even under demanding conditions.

The 040220A is equipped with an overhead valve (OHV) design, which enhances engine efficiency and provides better fuel economy. This technology allows for improved airflow and better combustion, resulting in increased power output while reducing emissions. With its advanced engineering, the engine is capable of delivering consistent performance across a range of applications, making it a versatile choice for both residential and commercial users.

Another important characteristic of the 040220A is its easy starting system. Designed for user convenience, this engine features a user-friendly recoil start mechanism that ensures reliable ignition with minimal effort. This is particularly beneficial for users who value time efficiency and want to avoid the hassle of complicated starting procedures.

The 040220A also boasts impressive torque and horsepower ratings, which contribute to its ability to handle tough tasks with ease. This engine is designed to provide ample power for heavy-duty cutting, mulching, and other demanding applications, ensuring that users can complete their work efficiently.

In addition to its power and performance, the Briggs & Stratton 040220A is also designed with user maintenance in mind. It features easy-access oil fill and drain ports, making routine maintenance tasks straightforward. This attention to user convenience helps ensure that owners can keep their engines in optimal working condition with minimal effort.

Overall, the Briggs & Stratton 040220A stands out as a reliable and powerful engine that incorporates advanced technologies and features aimed at enhancing performance and ease of use. Its robust design, efficient operation, and commitment to user convenience make it an excellent choice for anyone in need of a dependable engine for their outdoor power equipment. Whether you're a DIY enthusiast or a professional landscaper, the 040220A is engineered to meet your needs with proven performance and reliability.