Briggs & Stratton 01938-0 Table of Contents, Equipment Description, Customer Responsibilities

Page 2

Briggs & Stratton Power Products Home Generator

Installation Manual

TABLE OF CONTENTS

 

TABLE OF CONTENTS

. . . 2

EQUIPMENT DESCRIPTION

. . . 2

CUSTOMER RESPONSIBILITIES

. . . 2

INSTALLER RESPONSIBILITIES

. . . 2

SAFETY RULES

. . . 3

INSTALLATION PROCEDURES

. . . 4

Unpacking Precautions

. . . 4

Delivery Inspection

. . . 4

Shipment Contents

. . . 4

Required Specialty Tools/Equipment

. . . 4

Home Standby Generator Location

. . 4-5

Fuel and Electrical Inlet Dimensions

. . . 5

Lifting the Generator

. . 5-6

Access Doors

. . 6-7

THE GASEOUS FUEL SYSTEM

. 7-8

Fuel Consumption

. . . 9

Fuel Pipe Sizing

. . . 9

KNOW YOUR SYSTEM CONTROL BOARD

. . 10

Generator AC Connection System

. . 11

Grounding the System

. . 11

Utility Control Circuit Connection

. . 11

Fault Detection System

. . 11

System Control Panel

. . 12

BEFORE INITIAL ENGINE START-UP

. . 12

Engine Oil

. . 12

Battery Connection

12-13

Fuel Supply System

. . 13

FUEL SYSTEM SELECTION

. . 13

INITIAL START-UP (NO LOAD)

. . 14

Engine Adjustment

14-15

AUTOMATIC OPERATION SEQUENCE

. . 15

SETTING EXERCISE TIMER

. . 16

INSTALLATION INSPECTION

. . 16

Fuel Comparison Chart

. . 17

Size of Propane Tank Required at Various Temperatures

When Kept at Least Half Full

. . 17

Copyright © 2006 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.

EQUIPMENT

DESCRIPTION

This product is intended for use as an optional home standby system which provides an alternate source of electric power and to serve loads such as heating, refrigeration systems, and communication systems that, when stopped during any power outage, could cause discomfort, or the like.This product DOES NOT qualify for emergency standby as defined by NFPA 70 (NEC).

This manual contains installation, startup and adjustment instructions for a Home Standby Generator that supplies 120/240 Volt, single phase, 60Hz devices.The Home Standby Generator may be operated on LP or natural gas fuel. A separate operator’s manual (part number 192384GS) contains specifications, operating and maintenance instructions for these models.

Every effort has been made to ensure that the information in this manual is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve the system at any time without prior notice.

CUSTOMER RESPONSIBILITIES

Read and follow the instructions given in the Operator’s Manual, especially the section regarding selecting essential circuits.

Follow a regular schedule in maintaining, caring for and using your Home Standby Generator, as specified in the Operator’s Manual.

INSTALLER RESPONSIBILITIES

Read and observe the safety rules.

Refer to the list of recommended UL approved transfer switches that is compatible with the Home Standby Generator elsewhere in the carton.

Read and follow the instructions given in this Installation and Start-up Manual.

IMPORTANT: If operating the generator below 40°F, it is recommended that a battery and oil warmer be installed. If operating the generator below 32°F, a battery and oil warmer MUST be installed. Both

items are available at your local servicing dealer.

2

Image 2
Contents 10kW / 12kW Rated Equipment Description Table of ContentsInstaller Responsibilities Customer ResponsibilitiesRotating Parts Electrical Shock Important Safety RulesHazard Symbols and Meanings Amp fuse Before working on the equipmentInstallation Procedures Conduit Attachment Fuel and Electrical Inlet DimensionsLifting the Generator AreaInsert Access DoorsBattery DoorGaseous Fuel System Installation Manual To Remove an Access DoorTo Install an Access Door From Fuel To Home Standby10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ft Fuel ConsumptionFuel Pipe Sizing LoadRemote LED Output Volt DC, .5 Amp Output Internal power supplyKnow Your System Control Board Generator AC Connection System Fault Detection SystemTo install the remote LED panel Grounding the GeneratorSystem Control Panel Battery ConnectionBefore Initial START-UP Engine OilDo not dispose of battery in a fire Servicing the BatteryTo configure the fuel system for LP use Fuel System SelectionInitial START-UP no Load Engine AdjustmentInstall the 15 Amp fuse in the control panel Automatic Operation Sequence Engine Cool-down TimerAdjustment Nut Utility Voltage Dropout SensorTo perform the Set Exercise procedure Setting Exercise TimerInstallation Inspection Withdrawal Rate 32F 20F 10F 30F 40F Fuel Comparison ChartPhysical Properties Butane Propane Natural Gas Responsabilidades DEL Cliente Tabla DE ContenidoDescripción DEL Equipo Responsabilidades DEL InstaladorSímbolos de Peligro y Significados PrecauciónAdvertencia ExplosiónProcedimientos DE Instalación NPT Dimensiones de la Entrada para Electricidad y CombustibleElevación del Generador 13.5Para Retirar una Puerta de Acceso Puertas de AccesoPara Entrada de CombustibleSistema DE Combustible Gaseoso Advertencia Para Instalar una Puerta de AccesoFigura 19 Manómetro Instalado Transitoriamente Modelo Gas Natural Vapor de PL Dimensiones de la Cañería de CombustibleConsumo de Combustible Gas Natural peso específico =Conozca LA Tarjeta DE Control DE SU Sistema Interconexiones del Circuito de Control Sistema de Conexión de c.a. del GeneradorConexión a Tierra del Generador Sistema de Detección de FallasAceite de Motor Antes DEL Arranque Inicial DEL MotorPanel de Control del Sistema Conexión de la BateríaSelección DEL Sistema DE Combustible Para configurar el sistema de combustible para uso de LPPeligro Sistema de Suministro de CombustibleFije el interruptor AUTO/OFF/MANUAL en la posición Arranque Inicial SIN CargaInstale el fusible de 15 Amperios en el panel de control Cargue el generador al valor nominal de gas natural Ajuste del MotorDel Regulador Inspección Posterior a LA Instalación Configuración DEL Temporizador DE PrácticaSecuencia DE Operación Automática Tasa de consumo 32F 20F 10F 30F 40F Cuadro de Comparación de CombustiblesPropiedades físicas Butano Propano Gas natural Table DES Matières Responsabilités DE LinstallateurGuide dInstallation Description DE LéquipementExplosion Feu Symboles de Danger et MoyensAvertissement Procédures Dinstallation Connecteur de tuyauterie De combustible Directives Générales Concernant lEmplacementSoulèvement de la Génératrice Pour Tuyau ici Tuyau fourni par linstallateurPortes dAccès Pour enlever une porte daccèsPour installer une porte daccès LE Système DE Combustible Gazeux AvertissementLe groupe électrogène a été réglé en usine pour Il faudrait inclure une sortie pour manomètreModèle Gas Naturel Vapeur PL Consommation de CombustibleGrosseur du Tuyau de Combustible Gaz Naturel densité = 0,65Sortie de panneau DEL à distance Système de Branchement C.A. de la Génératrice Interconnexions du Circuit de CommandeTableau de Commande du Système Mise à la Masse de la GénératriceBranchement de la Batterie Avant LE Démarrage Initial DU MoteurHuile à Moteur Réglez linterrupteur AUTO/OFF/MANUAL sur Auto Sélection DU Système DE CombustibleSystème dAlimentation en Combustible Entretien de la BatterieRéglez linterrupteur AUTO/OFF/MANUAL sur Manual Démarrage Initial SansRéglage du Moteur Du RégulateurRéglage DE LA Minuterie DE Cycle Dexercice Vérification InstallationSéquence DE Fonctionnement Automatique Densité 31,26 Charte de Comparaison des CombustiblesPropriétés physiques Butane Propane Gaz naturel Poids† Indice d’octane Recherche