Craftsman 580.32561 operating instructions Connecting Electrical Loads, Stopping the Engine, Burns

Page 11

To Start The Engine

DisconnectatI ebctricai loads from the generator. NEVER start or stop engine with electricai devices piugged in and turned ON. Foilow start instruction steps in numerical order:

1. Make sure unit is on a ievei surface.

iMPORTANT:Failureto start and operate unit on a level surface wiii cause the unit not to start or shut down during operation.

2. Turn redfuei vaiveto "On" position.

3. Place choke lever in "Choke" position.

 

WARNING

 

Contactwith muffler areacan result in serious

 

burns.

_

Exhaust heat/gases can ignite combustibies,

 

structures or damage fue! tank causing a fire.

oDONOTtouch hotpartsandAVOIDhot exhaustgases.

®Allowequipmentto coolbeforetouching.

oKeepat least5 feet(1.5m) of clearanceonall sidesof generatorincludingoverhead.

Codeof FederalRegulation(CFR)Title36 Parks,Forests,and PublicPropertyrequireequipmentpoweredby aninternal combustionengineto haveasparkanester,maintainedin effectiveworkingorder,complyingto USDAForestservice standard5100-1Cor laterrevision.Inthe Stateof Californiaa sparkarresteris requiredundersection4442ofthe CaBornia Publicresourcescode.Otherstatesrnayhavesimilarlaws.

4.Set rocker switch to "Off'position.

5.Grasp recoil handleand pulI slowly until slight resistance is felt. Then pull rapidty to start engine.

WARNING

Startercord kickback (rapid retraction) can result

nbodiiy injury. Kickbackwiii puli handand arm toward engine faster than you can bt go.

Broken bones, fractures, bruises, or sprains sould result.

Whenstartingengine,pul!cordslowlyuntil resistanceisfelt and then pullrapidlyto avoidkickback.

oNEVERstart orstopenginewith ebctricaldevicespluggedin andturnedon.

t_IPORTANT:If enginefloods, place choke lever in "Rue" position and crank untii engine starts.

6.Move choke iever to "Rue" position a short distance at a time over severaiseconds in warm weather or

minutes in cold weather. Let engine run smoothly before each change. Operatewith choke in "Rue" position.

NOTE:if engine starts after 3 pulls but faiis to run, or if unit shuts down during operation, makesure unit is on a level surface and check for proper oii ieveI in crankcase. This unit may beequipped with a iow oii protection device. If so, oil must be at proper level for engineto start.

Connecting Electrical Loads

*Let the engine stabiiize and warm up for a few minutes after starting.

oDONOTconnect240Volt loadsto 120Voit receptacbs. * DO NOTconnect 3-phase ioads to the generator. o DO NOTconnect 50 Hzioads to the generator.

oMug in and turn on the desired 120 Volt AC, singie phase,60 Hertz eiectricai ioads.

oDO NOTOVERLOADTHEGENERATORSee. Don't Overload Generator.

NOTICE

Exceedinggeneratorswattage/amperagecapacity can damagegenerator and/or ebctricaI devicesconnected to it.

DONOTexceedthe generator'swattage/amperagecapacity.See Don?OverloadGeneratorinthe Operationsection.

Startgeneratorandletenginestabilizebeforeconnecting electricalloads.

Connectebctricalloadsin OFFposition,thenturn ONfor operation.

TurnelectricalloadsOFFanddisconnectfromgeneratorbefore stoppinggenerator.

Stopping the Engine

1.Turn off and unpiug ati eiectricai ioads from unit. NEVERstart or stop enginewith ebctricat devices ptugged in andturned on.

2.Let engine run at nooioadfor two minutes to stabilize unit'sinternal temperatures.

3.Move rocker switch to "Off" position.

i wAR. .G

Backf re, fire or engine damagecould occur.

Io DONOTstopenginebymovingchokeleverto "Choke"position.

4. Move fuel valveto "Off" position.

11

Image 11
Contents Hours Man. =Fri a.m. to 5 p.m. CT Safety Assembly Operation Maintenance PartsSears, Roebuck and Co., Hoffman Estates, JL 68179 U.S.A Additional One-Year LimitedWarranty on Craftsman Generator Hazard Symheis and Nteanings WarnsngWnenadding or Draningfuel Contactwith muffler areacan result in serious burnsUnintentionai sparking can result in fire or electric shock WhenadjustingorviakinorepairstoyourgeneratorKnowyourgenerator Adjustments. Savethis manual for future referenceCarten Centents TfyouhaveanyprobbmswiththeassemMyofyourNstall Wheel Kit Unpacking the GeneraterWhenaddingfuel Beforestartingthe GeneratorAdd Engine Oil Page Generater Lecatien Howto Useyour GeneratorSystem Ground Cennecting te a Buildings Electrical SystemBurns Connecting Electrical LoadsStopping the Engine 128/248 VeJt AC, 38 Amp, Locking Receptacle Csbdsetsand ReceptaclesVolt AC, 28 Amp, #uplex Receptacles VCR DontoverloadgeneratorCapacity Exhaust EngineSpecificationsPower Ratings Generator $pe¢ificatiensGeneralbecommendations MaintenancescheduleBenebatobmaintenance Generater Cleaning8il EnginemaintenanceKEEPOUTOFREACHOFCHILDREN.DONT Service Air CleanerCtean Spark Attester Screen Structures or damagefuel tank causing a fireAir Cooling System CJeanepJace Spark PJu9Pretect Fuel System Leng Term Sterage nstructiensGenerater Other Storage TipsContactSears or other quatified Engine is running, but no AC output is availablePage CRAFTSMAN5600 Watt AC Generator CRAFTSMAN5600 Watt AC Generator 580S25610 900 CRAFTSMAN5600 Watt AC Generater 580,325610 Main Unit Parts ListPage Bearing StatorAxle 196517GSWheel B1764GS SUPPORT,Wheel Kit 191267HGS742 746\ 307 741 ENGINE, Briggs and $tratten, 204412 Exploded View718A $52ENIINE, lri!£s and $tratton, 204412 Expletet View Carburer Overhaul KIT 3os %ENGINE, Brigis and Straiten, 204412 Exploded View Descriptian ENGJHE,Briggs and $tratten, 284412 Parts ListPage Cnverale EmJion information Garantia Hmitada de un ae adidenai del generader Craftsman GARANTJAOOdPLETADE UN ANO DEL GENERADORCRAFTSdANPeligro Cuando Anada COIBUSTBLE0 VACiEEL Depsito AdvebtenciaAviso AdvertenciaADVERTENCtA PrecaucionConozcasugenerador Coloquelacajadecartonen unasuperficierigiday plana Desembalaje del GeneraderCentenido de la Caja Instale el Juege de RuedasAgregar Aceite al Metor Antes DE Darle Arranqueal GenebadobAVlSO SERINGERIDO.Eviteel contacto con los ojos, la Elusodeconservantedecornbustiblerna!tieoeelcombustibleerNOtoquelosalarnbrespdadoso receptculos Como Usar SU GeneradorTierra dei Sistema Conexi6n amSistema Ei6drico de un EdifidoEl retroceso reptbgue r@ido det cable del Encienda eJ MotorConexion de Cargas Eieerieas Detener eJ Meter128/248 Voltios AC, 38 Amp, Receptcule de Juego DE Cables DEL Adaptadordel GeneradorVoJt AC, 28 Amp, Receptculos DohJes Ejemple No SobrecarguegeneradorCapacidad ControJde la EneraEspecificaciones de Generader MotorEspecihcacionesel Producto Peten¢ia NeminalLimpieza del Generader Programade MantenjmientoRecoiviendacionesgenerales Controlde EIVlISiONESResultado eI fuego o eI gotpe etctrico Anteni Iento DEL OtorAceite Servicio dei Depurador de Aire Ajuste del Carhurader LJmpJe/ReempJacela BujaLimpie ia Pantalla Apagachispas $istema de Refrigeraci6n de AirePretee¢in del $istema de Cembestible Problema Page Page Page Ne habr cargee Nfermac6n sehre emisiones 888 o784-6427 Wwwmea rs,com