Konica Minolta 752 operation manual Disposal Precaution, Precaution on Installation Location

Page 12

Precaution

"Disposal Precaution

When disposing the following used parts, accept the regulations of each local government.

1)The DRYPRO 752 itself.

2)The packaging materials for DRYPRO 752.

3)The photosensitive materials used on the DRYPRO 752.

4)The lead and lithium batteries inside the DRYPRO 752, which can be hazardous and must be disposed properly.

"Precaution on Installation Location

Be sure to observe the following conditions for the installation location of this device.

By installing this device in the Radiology Department, you could make the work flow smooth.

1)Install the device in a location where it is not exposed to water.

2)Install the device in a location where it is not exceed the temperatures or atmospheric pressure described in the specifications.

3)Install the device in a location where it is not exposed to direct sunlight.

4)Install the device in a flat place.

5)Install the device where there is no likelihood of being given by vibration or impact.

6)Install the device in a location where there is no likelihood of being adversely affected by chemical agents, or air containing gas, dust, salt or sulfur, etc.

[NOTE] : If the contents of this page are not legible, order a new manual.

x DRYPRO MODEL 752 Operation Manual Ver.0.11 2002.6

Image 12
Contents Drypro model Blank DRY Laser Imager Drypro Model Introduction Operation environmentImaging environment Sorter LiS-752 is optional deviceDescriptions of Symbol Mark Symbol mark Descriptions of symbol markDescriptions on Warning Label Descriptions on warning caution labelPage Front Rear Safety Caution Be sure to ground the device wellPlug the power cable completely Be careful not to trip over the power cable to damage itDo not operate the switches with wet hands When unplugging the power cable, do not pull it Precaution Disposal PrecautionPrecaution on Installation Location Name of Each Component Main BodyFront View Rear View Sorter LiS-752 option Structure How To Operate Control PanelDescription on screen Start-up Operation Power saving mode When Start Timer is not set to on Shut-down OperationWhen Start Timer is set to on Touch OK to perform Operation OFF proce- dureShut-down Operation Film Loading Resin tray Seals at the edges of the package Push the tray to the back until it is locked Film Loading Maintenance Mode Function of Maintenance ModeSwitching Maintenance Mode Start-up maintenance modeShut-down maintenance mode Touch MaintenanceHow To Operate Maintenance Mode Setting Start Timer FunctionSetting Date/Time Time SET Touch Previous Print on the maintenance menu screen Re-printing Printed Page Previous PrintTouch on the upper part of the screen Touch the box on the right of Copy and input the print count Touch a LUT name you wish to apply for printing DensityTouch Store MIN DensityCalibration Touch Calibration on the maintenance menu screen Calibrating Density CalibrationAutomatic calibration Test Print Selected user LUT name will be highlighted Touch OK How to control density Touch Cover Open on the maintenance menu screen Opening/closing front cover Cover OpenAdjusting control panel Panel Adjust Touch ExitHow To Operate Maintenance Mode Clearing queued print data Queue Clear Touch OK on the confirm message Cold Start Confirming and setting film count data Touch Film Data on the maintenance menu screenConfirming film count data Weekly film count Monthly film countSetting film count preference Touch Film Data Setup on the film count data screenSetting print preference Touch Print Condition on the maintenance menu screenPrint preference set screen 3/7 will appear Select the item to be printed as the stamp with Stamp Select After the settings are complete, touch Exit Sets the format of date to be printed on the filmSetting user LUT Touch the user LUT name to be set on the LUT select screenTouch LUT Library Touch the name of the LUT to be appliedTouch User LUT on the maintenance menu screen Creating user LUTTouch Data on the lower part of the screen Touch Edit on the LUT data screen Confirming the LUT curveSetting power saving mode Touch Power Save on the Maintenance Menu screenHow To Operate Maintenance Mode Troubleshooting Error Display and RemedyError Code Description Remedy Error Display and Remedy Resetting Errors When an error cannot be reset Touch Error QueueRe-starting When Cover Open is displayed When Sorter Cover is displayedRemoving Jam Jam in tray Press in the tray until it locksFilm outlet cover Green edge Film jam between Hpro section and cooling/discharge section Removing Jam Film jam in sorter Sorter left cover Cutouts When Film Fails to be Loaded Touch ON/OFF Line to switch into OFF Line Touch OK Touch Exit to end the maintenance mode When Film Fails to be Loaded Service and Maintenance Periodical Maintenance and InspectionOuter cover of the main unit Inside of main unitReplacing Filter Before replacing the FILTER, be sure to touch FILService and Maintenance Schedule Other service and maintenanceServicing by a user Confirming maintenance and maintenance display Specifications Drypro ModelSorter Option Specifications Appendix Time zone and code No. tableHandling and Storage of Unexposed Film Handling and Storage of Developed FilmBlank Blank