Sanyo SRT-2400DC Normal Recording, Concerning the Number of Times Tapes can be Rerecorded on

Page 21

NU4QG/NA3 (SRT-2400DC GB) Mon. Sept., 17/2001

NORMAL RECORDING

Concerning the Number of Times Tapes can be Rerecorded on

Depending on the recording speed mode, the tape must be replaced after a certain number of recording times.

Refer to the table below for the maximum number of times a tape can be recorded on.

Recording speed mode

Maximum number of

(hour mode)

recording times

 

 

(with a standard grade

 

 

tape)

6,

8

100

 

 

 

18,

24

50

 

 

 

30,

40

50

 

 

 

NOTES:

The maximum number of recording times will vary depending on the location and kind of tape used. Verify the recording quality and replace the tape when the quality starts to deteriorate.

The maximum number of recording times indicated above are based on test tapes (T-120 or T-160) used by the company.

If using longer tapes (i.e. T-180) the tape travel will not be as stable and that may cause problems.

Record Pause

Recording can be interrupted temporarily.

1Press the PAUSE/SEARCH button during recording.

°The Pause/Still indicator :blinks.

NOTES:

The image appears on-screen but it is not recorded.

If a recording pause continues for 5 minutes or more, the VCR will go into stop mode to avoid damaging the tape.

2To resume recording, press the REC button, or press the PAUSE/SEARCH button again.

Recording Check

The image being recorded can be checked.

1During recording, press the PLAY (REC CHECK) button.

°The tape will be rewound and then played back. The VCR will then return to the previous recording mode.

NOTE:

During recording check operations, recording is suspended momentarily.

Clog Detection

This VCR is equipped with a clog detection function.

The recording quality is monitored automatically. When the heads are dirty and the recording quality deteriorates, the output at the WARNING OUT terminal becomes 0V (Low), the “a” indicator flashes on the digital display, and the buzzer sounds.

If in the (SET UP 3) menu, CLOG DETECT. is set to “N”, the recording quality is not monitored.

NOTES:

To cancel the “a” indicator display and reset the WARNING OUT terminal output, press the STOP button.

Clog detection is not possible if recording in 8-hour mode.

20

English

Image 21
Contents SRT-2400DC For the customers in Canada PrecautionsMoisture Condensation Problems PrecautionsLocation Avoiding Electrical Shock and FireFeatures ContentsFront Panel Locations of Controls and IndicatorsLocations of Controls and Indicators Operation IndicatorsDigital Display Wvut Q O N Back PanelBack Panel With the optional RS-485 board About the memory reset DC power source output DC power maximum cord LengthsConnections ON-SCREEN Menus ON-SCREEN Menus Language Setting Setting the Language and ClockClock setting Setting procedure is now completedAutomatic Daylight Saving Time Adjustment Setting the Language and ClockSelecting the On-screen Display Changing the ON-SCREEN DisplayChanging the Date/Time Display Position Date and time are displayedVideo Cassette Tapes Setting the Type of Tape Used Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionOperation Tape Management FunctionIf no tape management data is present on the tape If tape management data is present on the tape Tape Management Function Setting the Tape Management FunctionConflict display sample Tape Management Conflict DisplayWhen Tape in the SET UP 5 menu is set to T-160 Recording Speed ModeWhen Tape in the SET UP 5 menu is set to T-120 Normal RecordingConcerning the Number of Times Tapes can be Rerecorded on Normal RecordingRecord Pause Recording CheckAction to Take when the Video Signal Deteriorates Changes to the Recording Speed Mode During RecordingTape Counter Notes Setting the Mode at the End of the TapeRepeat indicator will light Autorepeat RecordingAutorepeat Recording Alarm Recording Alarm Recording SettingAlarm Mode setting is flashing Alarm Recording Alarm Recording Counter DisplayChecking the Alarm Recordings Time Alarm Scan Alarm SearchProgram Timer Recording Day of the week of the 8th line is flashing Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording will start in series recording mode Series Recording SetupSeries Recording Series recording connectionsContinous Loop Recording Setup Series RecordingLoop recording connection example with 2 VCRs Normal Playback Normal PlaybackTracking Control Vertical Lock ControlPicture Search Forward and Reverse Special PlaybackStill Image Field AdvanceDAY/TIME Search Setting the Security LockDay/Time Search Search 01 0000 will be displayed on screenSetting the Buzzer Clock AdjustmentSetting procedure on the first VCR is now completed Cassette Eject Setup Setting the Cassette Eject ModeEject terminal connection Eject in terminalAddress setting is flashing Settings for RS485 Terminals USE@@@@POWER@FAILURE SW OUT Terminal Output Setting Tape END OUT Terminal Output SettingOutput Terminals Tape END OUT TerminalAlarm IN/CLOCK in and Alarm OUT/CLOCK OUT terminal setting Series OUT/NON REC OUT terminal settingInput Output setting is flashing Output TerminalsRemote control setting Remote JackCOM Terminal Output Terminals Maintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyNU4QG/NA3 SRT-2400DC GB Mon. Sept., 17/2001