Sanyo SRT-2400DC instruction manual Setting the Buzzer, Clock Adjustment

Page 37

NU4QG/NA3 (SRT-2400DC GB) Mon. Sept., 17/2001

SETTING THE BUZZER

A buzzer can be set to sound during alarm recording, if during recording the tape reaches the end, if buttons are pressed or if there is a mechanical failure that causes the tape to stop or be ejected, etc.

1Press the MENU button until the (SET UP 2) menu is displayed.

@@@@@@@<SET@UP@2>

*DISPLAY

@@@DATE@@@@@@@@@@@Y

@@@TIME@@@@@@@@@@@Y

@@@ALARM@COUNT@@@@Y

@@@SPEED@@@@@@@@@@Y

*BUZZER

@@@ALARM@IN@@@@@@@Y

@@@TAPE@END@@@@@@@Y

@@@KEY@IN@@@@@@@@@N

@@@WARNING@@@@@@@@Y

KEY IN . . . . . . The buzzer will be heard when one of the VCR buttons is pressed.

WARNING . . . The buzzer will be heard if the heads are dirty and recording qualtiy deteriorate, or if the tape stops or is ejected due to a problem with the internal mechanism. To stop the buzzer, press the STOP button.

4Press the PAUSE/SEARCH button to save the setting.

2Press the ] button, until the desired item for which the buzzer function will be set is flashing.

3Press the l (or j) button to set “Y” for the functions described below.

ALARM IN . . . The buzzer will be heard during alarm recording.

TAPE END . . . The buzzer will be heard when the end of the tape is reached during recording. To stop the buzzer, press the STOP, EJECT, FF, REW or PLAY button.

NOTES:

If “N” is set, the buzzer will not be heard.

During timer recording mode, security lock engaged mode and alarm recording mode, the buzzer will not be heard when a button related to one of these modes is pressed, even if “Y” is set for the “KEY IN” item.

CLOCK ADJUSTMENT

When using 2 or more VCRs of this same model, the clock on the second VCR and on, can be synchronized with the clock on the first VCR, using the CLOCK ADJUSTMENT function.

To use CLOCK ADJUSTMENT function, “INPUT OUTPUT” in the (SET UP 5) menu must be set to “CLOCK SET”.

1Connect the ALARM OUT/CLOCK OUT terminal on VCR 1 to the ALARM IN/CLOCK IN terminal on VCR 2.

2Repeat the procedure for all the other VCRs, connecting the ALARM OUT/CLOCK OUT terminal on VCR 2 to the ALARM IN/CLOCK IN terminal on VCR 3, and so on.

3Press the MENU button until the (SET UP 3) menu is displayed.

4Press the ] button, until the “EXT TIME ADJ.” setting is flashing.

5Press the l (or j) button to set the hour at which the adjustment will be conducted.

Example

@@@@@@@<SET@UP@3>

*ALARM@MODE@@@@@@@Y1

*ALARM@SPEED@@@@@@8H

*ALARM@DURATION@@@20S

*VERTICAL@SYNC@@@@Y

*EXT@TIME@ADJ.@@@@03:00

*TAPE@IN@MODE@@@@@STOP

*TAPE@END@MODE@@@@REW *TAPE@END@OUT@@@@@-3M *CLOG@DETECT.@@@@@Y *SERIES@REC@IN@@@@N

6Press the PAUSE/SEARCH button to save the setting.

°The setting procedure on the first VCR is now completed.

7Repeat the procedure for all the other VCRs, setting “EXT TIME ADJ.” (to the same time as set on the first VCR).

NOTES:

Connect the COM terminal on all VCRs used.

This function will not operate on the day the daylight saving/standard time is changed.

NOTES:

Be sure to set the same time on all the VCRs.

The clock adjustment cannot be set to “00:00”.

36

English

Image 37
Contents SRT-2400DC For the customers in Canada PrecautionsMoisture Condensation Problems PrecautionsLocation Avoiding Electrical Shock and FireFeatures ContentsFront Panel Locations of Controls and IndicatorsOperation Indicators Locations of Controls and IndicatorsDigital Display Wvut Q O N Back PanelBack Panel With the optional RS-485 board DC power source output DC power maximum cord Lengths About the memory resetConnections ON-SCREEN Menus ON-SCREEN Menus Language Setting Setting the Language and ClockClock setting Setting procedure is now completedAutomatic Daylight Saving Time Adjustment Setting the Language and ClockSelecting the On-screen Display Changing the ON-SCREEN DisplayChanging the Date/Time Display Position Date and time are displayedVideo Cassette Tapes Setting the Type of Tape Used Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionOperation Tape Management FunctionIf no tape management data is present on the tape If tape management data is present on the tapeTape Management Function Setting the Tape Management FunctionConflict display sample Tape Management Conflict DisplayWhen Tape in the SET UP 5 menu is set to T-160 Recording Speed ModeWhen Tape in the SET UP 5 menu is set to T-120 Normal RecordingConcerning the Number of Times Tapes can be Rerecorded on Normal RecordingRecord Pause Recording CheckAction to Take when the Video Signal Deteriorates Changes to the Recording Speed Mode During RecordingTape Counter Notes Setting the Mode at the End of the TapeAutorepeat Recording Repeat indicator will lightAutorepeat Recording Alarm Recording Setting Alarm RecordingAlarm Mode setting is flashing Alarm Recording Counter Display Alarm RecordingChecking the Alarm Recordings Time Alarm Scan Alarm SearchProgram Timer Recording Day of the week of the 8th line is flashing Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording will start in series recording mode Series Recording SetupSeries Recording Series recording connectionsSeries Recording Continous Loop Recording SetupLoop recording connection example with 2 VCRs Normal Playback Normal Playback Tracking Control Vertical Lock ControlPicture Search Forward and Reverse Special PlaybackStill Image Field AdvanceDAY/TIME Search Setting the Security LockDay/Time Search Search 01 0000 will be displayed on screenClock Adjustment Setting the BuzzerSetting procedure on the first VCR is now completed Cassette Eject Setup Setting the Cassette Eject ModeEject terminal connection Eject in terminalAddress setting is flashing Settings for RS485 Terminals USE@@@@POWER@FAILURE SW OUT Terminal Output Setting Tape END OUT Terminal Output SettingOutput Terminals Tape END OUT TerminalAlarm IN/CLOCK in and Alarm OUT/CLOCK OUT terminal setting Series OUT/NON REC OUT terminal settingInput Output setting is flashing Output TerminalsRemote Jack Remote control settingCOM Terminal Output Terminals Maintenance Maintenance Table MaintenanceMaintaining and Checking The Mechanism After a Power Failure Troubleshooting GuideSystem Down Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyNU4QG/NA3 SRT-2400DC GB Mon. Sept., 17/2001