NU4QG/NA3
OUTPUT TERMINALS
WARNING OUT Terminal
•
•
If the tape stops or other problem, the output becomes 0V (Low).
To reset the output, press the STOP or ALL RESET button or unplug the power cord then plug it back in.
Tape movement stop
Output reset
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)
WARNING OUT Terminal Output Setting
1Press the MENU button until the (SET UP 5) menu is displayed.
@@@@@@@<SET@UP@5>
*INPUT@OUTPUT@ALARM
*OUTPUT@@@@@@@SERIES
*WARN.@OUT@@@@TRANSPORT
*REMOTE@@@@@@@EJECT
2Press the ] button, until the “WARN. OUT” setting is flashing.
3Press the l (or j) button, to select the desired output mode.
TRANSPORT. The output becomes 0V (Low) when the tape stops or other probrem with the internal mechanism.
V. LOSS . . . . . The output becomes 0V (Low) when there is no video signal (Please refer to page 21, “Action to Take when the Video Signal Deteriorates.”).
T OR V . . . . . . The output become 0V (Low) when the tape stops or other problem with the internal mechanism, or when there is no video signal (Please refer to page 21, “Action to Take when the Video Signal Deteriorates.”).
NOTE:
•If in the (SET UP 4) menu “VIDEO LOSS” is set to “N”, the “WARN. OUT” setting will be preset to “TRANSPORT” and cannot be changed.
4Press the PAUSE/SEARCH button to save the setting.