Sanyo SRT-2400DC instruction manual Output Terminals, Series OUT/NON REC OUT terminal setting

Page 42

NU4QG/NA3 (SRT-2400DC GB) Mon. Sept., 17/2001

OUTPUT TERMINALS

SERIES OUT/NON REC OUT terminal setting

The output at the SERIES OUT/NON REC OUT terminal can be set.

1Press the MENU button until the (SET UP 5) menu is displayed.

NOTE:

If “OUTPUT” is set to “NON REC”, the “NON REC OUT” line will be displayed under the “OUTPUT” line.

@@@@@@@<SET@UP@5>

*INPUT@OUTPUT@ALARM

*OUTPUT@@@@@@@SERIES

*NON@REC@OUT@@ACTIVE@LOW

*WARN.@OUT@@@@TRANSPORT

*REMOTE@@@@@@@EJECT *TAPE@@@@@@@@@T-160

2Press the ] button, until the “OUTPUT” setting is flashing.

3Press the l (or j) button, to select the desired output mode.

SERIES . . . . . The SERIES OUT/NON REC OUT terminal will be set to

SERIES OUT.

If during series recording, the counter reading reaches 7:57:00 or the tape reaches the end, a LOW signal (0 V) is output. The LOW (0 V) signal is output for about 70 seconds after the end of the tape is reached.

NON REC . . . The SERIES OUT/NON REC OUT terminal will be set to NON REC OUT.

If “OUTPUT” is set to “NON REC”, please continue with step 4.

4Press the ] button.

5Press the l (or j) button to select the desired output.

ACTIVE LOW . . Normally DC 5V are output between the SERIES OUT/NON REC OUT and the COM terminals. If during recording the VCR enters a mode other than recording (i.e. recording pause, stop mode, etc.), the output become 0 V (Low). If recording is resumed, then the output become 5 V (High).

ACTIVE HIGH . . Normally 0V are output between the SERIES OUT/NON REC OUT and the COM terminals. If during recording the VCR enters a mode other than recording (i.e. recording pause, stop mode, etc.), the output become 5 V (High). If recording is resumed, then the output become 0 V (Low).

NOTES:

If “NON REC OUT” is set to “ACTIVE HIGH”, a throwaway pulse will be output from the SERIES OUT/NON REC OUT terminal when power is restored after an outage, when the power is turned on or when the ALL RESET button is pressed. This will continue until the microprocessor starts operating. If this output terminal is connected to some other device, the device should be set or adjusted so that it is not affected by the throwaway pulse. If set to “ACTIVE LOW”, this kind of pulse is not output, and so it is recommended that you use the “ACTIVE LOW” setting.

If in the (SET UP 2) menu, in the “BUZZER” section, “WARNING” is set to “Y”, a buzzer will be heard while the VCR is in non recording mode. The buzzer will stop if the STOP button is pressed (the output signal will remain).

6Press the PAUSE/SEARCH button to save the setting.

ALARM IN/CLOCK IN and ALARM OUT/CLOCK OUT terminal setting

1Press the MENU button until the (SET UP 5) menu is displayed.

°The “INPUT OUTPUT” setting is flashing.

2Press the l (or j) button to select desired input/output mode.

ALARM. . . . . . The ALARM IN/CLOCK IN terminal is set to ALARM IN and the ALARM OUT/CLOCK OUT terminal is set to ALARM OUT.

CLOCK SET. . The ALARM IN/CLOCK IN terminal is set to CLOCK IN and the ALARM OUT/CLOCK OUT terminal is set to CLOCK OUT.

3Press the PAUSE/SEARCH button to save the setting.

English

41

Image 42
Contents SRT-2400DC Precautions For the customers in CanadaLocation PrecautionsMoisture Condensation Problems Avoiding Electrical Shock and FireContents FeaturesLocations of Controls and Indicators Front PanelLocations of Controls and Indicators Operation IndicatorsDigital Display Back Panel Wvut Q O NBack Panel With the optional RS-485 board About the memory reset DC power source output DC power maximum cord LengthsConnections ON-SCREEN Menus ON-SCREEN Menus Clock setting Setting the Language and ClockLanguage Setting Setting procedure is now completedSetting the Language and Clock Automatic Daylight Saving Time AdjustmentChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Date and time are displayedVideo Cassette Tapes Video Cassette Tapes Setting the Action to Take When a Cassette is LoadedSetting the Type of Tape Used Correct tape thread check functionIf no tape management data is present on the tape Tape Management FunctionOperation If tape management data is present on the tapeSetting the Tape Management Function Tape Management FunctionTape Management Conflict Display Conflict display sampleWhen Tape in the SET UP 5 menu is set to T-120 Recording Speed ModeWhen Tape in the SET UP 5 menu is set to T-160 Normal RecordingRecord Pause Normal RecordingConcerning the Number of Times Tapes can be Rerecorded on Recording CheckChanges to the Recording Speed Mode During Recording Action to Take when the Video Signal DeterioratesSetting the Mode at the End of the Tape Tape Counter NotesRepeat indicator will light Autorepeat RecordingAutorepeat Recording Alarm Recording Alarm Recording SettingAlarm Mode setting is flashing Alarm Recording Alarm Recording Counter DisplayChecking the Alarm Recordings Time Alarm Search Alarm ScanProgram Timer Recording Program Timer Recording Day of the week of the 8th line is flashingTo Cancel a Program Timer Recording Setting the HolidaysChanging a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Series Recording Series Recording SetupRecording will start in series recording mode Series recording connectionsContinous Loop Recording Setup Series RecordingLoop recording connection example with 2 VCRs Tracking Control Normal PlaybackNormal Playback Vertical Lock ControlStill Image Special PlaybackPicture Search Forward and Reverse Field AdvanceDay/Time Search Setting the Security LockDAY/TIME Search Search 01 0000 will be displayed on screenSetting the Buzzer Clock AdjustmentSetting procedure on the first VCR is now completed Eject terminal connection Setting the Cassette Eject ModeCassette Eject Setup Eject in terminalSettings for RS485 Terminals USE Address setting is flashing@@@@POWER@FAILURE Output Terminals Tape END OUT Terminal Output SettingSW OUT Terminal Output Setting Tape END OUT TerminalInput Output setting is flashing Series OUT/NON REC OUT terminal settingAlarm IN/CLOCK in and Alarm OUT/CLOCK OUT terminal setting Output TerminalsRemote control setting Remote JackCOM Terminal Output Terminals Maintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeNU4QG/NA3 SRT-2400DC GB Mon. Sept., 17/2001