CONNECTIONS

Connect the video camera and monitor TV as shown in the figure below.

NOTE: Before making the connections, make sure all the devices are disconnected from the DC power supply.

Monitor TV (sold separately)

Video camera (sold separately)

From an external

 

 

 

To

 

 

 

VIDEO IN

audio source

 

 

 

 

 

 

jack

 

 

 

 

ALARM OUT/ ALARM IN/

SERIES OUT/

SERIES

SW

EJECT

CLOCK OUT CLOCK IN COM

NON REC OUT

IN

OUT

OUT IN

WARNING TAPE

 

 

 

 

OUT END OUT COM

 

 

COM

 

DC12V IN

 

AUDIO

VIDEO

PUSH

 

 

 

IN

 

 

 

 

OPEN

 

IN

 

 

REMOTE MIC IN OUT

 

OUT

 

 

 

 

 

 

To

To remote

 

 

VIDEO OUT

 

 

jack

control

 

 

 

 

 

(sold separately)

 

 

Coaxial cable

 

 

 

 

(sold separately)

To DC power supply

About the memory reset

If the VCR location is changed or to cancel previous settings, please reset the memory as described below.

The time and date will be reset, and the security lock will be cancelled.

To reset the memory, press the ALL RESET button.

NOTES:

For more details, please refer to the manuals accompanying all other devices. If the connections are not made properly, it may cause a fire or damage the equipment.

You can use a VA-RMN01 Remote Control Unit (sold separately) to control remotely the VCR.

If there is no video signal when the power is turned on, “NO VIDEO” will be displayed on-screen.

Use a DC power cord rated A.W.G 18 (1.25 mm2) or more.

The table below indicates the DC power source output and DC power maximum cord lengths.

DC power source output

DC power maximum cord

 

 

 

lengths

 

 

 

 

16 V

3

A

6 m

 

 

 

14 V

3.5 A

6 m

 

 

 

12 V

4.5 A

6 m

 

 

 

 

10 V

7

A

6 m

 

 

 

 

10 V

5

A

2 m

 

 

 

 

8

English

Image 9
Contents SRT-2400DC For the customers in Canada PrecautionsMoisture Condensation Problems PrecautionsLocation Avoiding Electrical Shock and FireFeatures ContentsFront Panel Locations of Controls and IndicatorsLocations of Controls and Indicators Operation IndicatorsDigital Display Wvut Q O N Back PanelBack Panel With the optional RS-485 board About the memory reset DC power source output DC power maximum cord LengthsConnections ON-SCREEN Menus ON-SCREEN Menus Language Setting Setting the Language and ClockClock setting Setting procedure is now completedAutomatic Daylight Saving Time Adjustment Setting the Language and ClockSelecting the On-screen Display Changing the ON-SCREEN DisplayChanging the Date/Time Display Position Date and time are displayedVideo Cassette Tapes Setting the Type of Tape Used Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionOperation Tape Management FunctionIf no tape management data is present on the tape If tape management data is present on the tapeTape Management Function Setting the Tape Management FunctionConflict display sample Tape Management Conflict DisplayWhen Tape in the SET UP 5 menu is set to T-160 Recording Speed ModeWhen Tape in the SET UP 5 menu is set to T-120 Normal RecordingConcerning the Number of Times Tapes can be Rerecorded on Normal RecordingRecord Pause Recording CheckAction to Take when the Video Signal Deteriorates Changes to the Recording Speed Mode During RecordingTape Counter Notes Setting the Mode at the End of the TapeRepeat indicator will light Autorepeat RecordingAutorepeat Recording Alarm Recording Alarm Recording SettingAlarm Mode setting is flashing Alarm Recording Alarm Recording Counter DisplayChecking the Alarm Recordings Time Alarm Scan Alarm SearchProgram Timer Recording Day of the week of the 8th line is flashing Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording will start in series recording mode Series Recording SetupSeries Recording Series recording connectionsContinous Loop Recording Setup Series RecordingLoop recording connection example with 2 VCRs Normal Playback Normal PlaybackTracking Control Vertical Lock ControlPicture Search Forward and Reverse Special PlaybackStill Image Field AdvanceDAY/TIME Search Setting the Security LockDay/Time Search Search 01 0000 will be displayed on screenSetting the Buzzer Clock AdjustmentSetting procedure on the first VCR is now completed Cassette Eject Setup Setting the Cassette Eject ModeEject terminal connection Eject in terminalAddress setting is flashing Settings for RS485 Terminals USE@@@@POWER@FAILURE SW OUT Terminal Output Setting Tape END OUT Terminal Output SettingOutput Terminals Tape END OUT TerminalAlarm IN/CLOCK in and Alarm OUT/CLOCK OUT terminal setting Series OUT/NON REC OUT terminal settingInput Output setting is flashing Output TerminalsRemote control setting Remote JackCOM Terminal Output Terminals Maintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyNU4QG/NA3 SRT-2400DC GB Mon. Sept., 17/2001