Code
F72
F73
F74
F75
F91
F92
F93
F94
F95
F96
F97
F98
F99
Function Code Name
Skew Detection
Latched Scanning Flag
Momentary Scanning Flag
Footswitch Confirmation Tone
Select Linked Mode
Fixed Field
Action/Confirmation Tone
Level 1
Level 2
Level 3
Next Image Address
Stop
Run
Description
Allows you to turn skew detection on or off which monitors the amount of skew using predefined skew angle(s). Enter 1 to turn on or 0 to turn off, then press Enter.
Allows you to set a flag in the image headers which alerts the host system that this document, and those which follow, are of special interest. The flag will remain activated for every document until it is turned off. Enter 1 to turn on or 0 to turn off, then press Enter.
Allows you to set a flag in the image header which alerts the host system that this document is of special interest. This flag is set only for that one document. Enter 1 to turn the momentary scanning flag on, then press Enter.
Allows you to turn the confirmation tone on or off which informs you when the Footswitch is pressed and/or released. Enter 1 to turn on or 0 to turn off, then press Enter.
Allows you to switch from one application mode to another, keeping the last image address. Enter the number of the application mode you wish to select, then press Enter.
Allows you to enter a new fixed field value containing alphanumeric characters.
NOTE: If the fixed field width for the mode you are using is 0, and E104 error will be displayed. To correct this, change to a mode that has a fixed field or modify the mode you are using so the fixed field is not 0.
Allows you to hear the pitch of the alarm tone.
Allows you to assign Level 1 to the next document fed into the transport.
Allows you to assign Level 2 to the next document fed into the transport.
Allows you to assign Level 3 to the next document fed into the transport.
Allows you to input the next image address. Enter the next image address, then press Enter.
Allows you to stop the transport.
Allows you to turn on the transport.
|