IBM CF Series manual Input Characteristics, Physical Specifications, Power Specifications

Page 14

Accuracy/ Repeatability

.04% lateral

Note: Measured over 40 inches for CF Series 44 scanners, and over 35 inches for CF400/36 scanner.

.04% longitudinal

Note: Measured over 20 inches for all CF Series scanners.

Imager Sensor Multiple CCD arrays

Transport Continuous feed

Input Characteristics

Document Width

44 inches (111.8 centimeters)

Active Scan Width

41 inches (104.1 centimeters) for models CF1000/44 and CF500/44

43 inches (109.2 centimeters) for model CF300/44

36 inches (91.4 centimeters) for model CF400/36

Document Length

Unlimited (if operator-feed skew is zero)

Document Thickness

.003 to .062 inches (.07 to 1.56 millimeters)

Media Types

Media types include paper, mylar, vellum, sepia, bluelines, onionskin, cardboard-backed paste-ups, and photographic negatives-among others.

Physical Specifications

Height

41 inches (112 centimeters)

Width

53 inches (132 centimeters)

Depth

20 inches (56 centimeters)

Weight

380 pounds (172 kilograms)

External Finish

Pearl Gray, Pebble Gray

Internal Finish

Anodized or painted (as appropriate)

Power Specifications

Power

600 watts maximum

Image 14
Contents CF Series Scanner Maintenance Manual Firmware Rev. S27G and up Scanner Serial NumberTrademark Notice Related Scangraphics Documentation PrefaceIf You Have Questions Table of Contents Connections ON-BOARD Diagnostic System Diagnostics Tests Saving Parameter Changes to NON-VOLATILE Memories  System Overview User Interface FeaturesMultiple Resolution Critical CalibrationDiagnostics ConstructionNominal Scan Speed/Resolution Chart SpecificationsFunctional Specifications Power Specifications Input CharacteristicsPhysical Specifications Environmental Specifications This page intentionally left blank Installation Connections POWER-UP DE-INSTALLATION System Description Major Systems of Scanner Model # of Cameras Page Page This page intentionally left blank Annually DailyMonthly Page On-Board Diagnostic System CF Series Scanner Main MenuPage This page intentionally left blank Set Global Parameters Global Parameters MenuPage Parameter Backup Perform System InitializationThis page intentionally left blank Set Motor Speed Set Motor Speed MenuPage Splice Counts Splice Count Listing Example from a CF 1000/44This page intentionally left blank Equipment, Tools & Materials Required Focus and MagnificationFocus and Magnification Menu This page intentionally left blank Focus Sample Focus DisplayPage Page This page intentionally left blank Magnification Procedure for Adjusting Camera Magnification Magnification Values for CF300 This page intentionally left blank IP LUT For the Image Processor Board Example of an Image Processor Board Look-Up Table IP LUT Merge and Splice Adjustment 17 Merge and Splice Adjustment MenuPage Page This page intentionally left blank Line Splice Adjustment Merge Adjustment Procedure for Adjusting Camera MergeAutosize Parameters 24 Set Autosize Parameters MenuSET CCB Registers a Test Frame Grabber BTest I/O Board C 26 I/O Board Test Menu27 I/O Board Sensor Test Offsets D 28 Page Offsets MenuThis page intentionally left blank Camera System Diagnostics E 29 Camera System StatisticsPage NE Normalize Exposure Gain Memory NG Normalize GainTake Line Display Calibration MemoryFill Calibration Memory Autotake Video Board Reset Not used 14.11 L0 Lights OffTake Qualified Line 14.12 L1 Lights OnAAAA,DD Calibration CheckMirror Control Test Pattern ControlCamera Response Curves Camera Delay Factory Use onlyCalibration Memory Test HistogramExit Resolution Control 31 Resolution Control DisplayPage Document Sizes 32 Set Document Size MenuRUN Self Tests CPU RAMRestore Nvram This page intentionally left blank Binary Filter Parameters Prompt Parameter Set A,B,C,D will appear IP Averager LUT Autocalibration Proceed With Calibration ? Y/NScsi Buffer Parameters 33 Scsi Buffer Parameters MenuThis page intentionally left blank System Parameters Procedure for Issuing the Save CommandPixel Correction and Exposure Values Page Procedure to Remove the Back Panel Procedure to Remove the Front CoverProcedure to Remove Either Side Panel Procedure for Replacing Belt and Adjusting Tension Procedure for Installing and Replacing Imaging Lamp Task -- Replacement of White Background Procedure for Replacing White BackgroundTask - Camera Assembly Removal and Replacement Procedure for Removing and Replacing Camera AssemblyProcedure for Adjusting Video Board Task -- Camera CalibrationCamera Board Offset Exposure CalibrationGain Calibration +12 Volts Task - Checking and Adjusting Voltages+5 Volts Volts+120 Volts Task - FAN Replacement Procedure for Replacing FansTask - Filter Cleaning and Replacement Terminal Setup II. Save the SetupIII. Host Serial Connection Appendix B Replacement Parts List