IBM CF Series manual Task -- Camera Calibration, Procedure for Adjusting Video Board

Page 93

6.6 TASK -- CAMERA CALIBRATION

The following conditions require calibration of the scanner’s cameras:

Replacement of any of the following components:

CCD Camera Board

Video Board

Imaging Lamp

Detection of image degradation

Adjustment of +5 V, or +12 V Linear power supply voltages.

All of the software tools for camera calibration are contained in the Camera System Diagnostics. Refer to the Diagnostics Tests software section 5.1.14 for details. The following calibrations must be performed to perfect the scanned image:

1.Adjust Video Board.

2.Adjust camera board offsets.

3.Calibrate camera exposures.

4.Calibrate camera gains.

6.6.1Video Board Adjustments

Equipment, Tools & Materials required:

Small flat head screwdriver or potentiometer tweaker

Digital voltmeter

Procedure for Adjusting Video Board:

1.Connect to negative lead of the voltmeter to TP4 on the Video Board.

2.Place the positive lead of the voltmeter on U5 pin 7.

3.Adjust potentiometer R21 until the voltage is zero.

4.Place the positive lead of the voltmeter on U5 pin 10.

5.Adjust potentiometer R20 until the voltage is zero.

6.Move JP1 and JP2 to their lower positions (position 2).

7.Activate “AUTOTAKE”, and enter camera number 0. See section 5.1.14.9 for details.

8.You should either see all zeros or some numbers on the screen

9.If you see all zeros, turn the potentiometer R34 until you start to see non-zero numbers. 10.As you observe the display, turn the potentiometer just until you see zeros come up on

the screen.

11.Move JP1 and JP2 back to their upper positions (position 1).

Image 93
Contents Firmware Rev. S27G and up Scanner Serial Number CF Series Scanner Maintenance ManualTrademark Notice Preface Related Scangraphics DocumentationIf You Have Questions Table of Contents Connections ON-BOARD Diagnostic System Diagnostics Tests Saving Parameter Changes to NON-VOLATILE Memories  System Overview Multiple Resolution FeaturesUser Interface Critical CalibrationConstruction DiagnosticsSpecifications Functional SpecificationsNominal Scan Speed/Resolution Chart Input Characteristics Physical SpecificationsPower Specifications Environmental Specifications This page intentionally left blank Installation Connections POWER-UP DE-INSTALLATION System Description Major Systems of Scanner Model # of Cameras Page Page This page intentionally left blank Daily MonthlyAnnually Page CF Series Scanner Main Menu On-Board Diagnostic SystemPage This page intentionally left blank Global Parameters Menu Set Global ParametersPage Perform System Initialization Parameter BackupThis page intentionally left blank Set Motor Speed Menu Set Motor SpeedPage Splice Count Listing Example from a CF 1000/44 Splice CountsThis page intentionally left blank Focus and Magnification Focus and Magnification MenuEquipment, Tools & Materials Required This page intentionally left blank Sample Focus Display FocusPage Page This page intentionally left blank Magnification Procedure for Adjusting Camera Magnification Magnification Values for CF300 This page intentionally left blank IP LUT For the Image Processor Board Example of an Image Processor Board Look-Up Table IP LUT 17 Merge and Splice Adjustment Menu Merge and Splice AdjustmentPage Page This page intentionally left blank Line Splice Adjustment Procedure for Adjusting Camera Merge Merge Adjustment24 Set Autosize Parameters Menu Autosize ParametersTest Frame Grabber B SET CCB Registers a26 I/O Board Test Menu Test I/O Board C27 I/O Board Sensor Test 28 Page Offsets Menu Offsets DThis page intentionally left blank 29 Camera System Statistics Camera System Diagnostics EPage NE Normalize Exposure NG Normalize Gain Gain MemoryDisplay Calibration Memory Fill Calibration MemoryTake Line Take Qualified Line Video Board Reset Not used 14.11 L0 Lights OffAutotake 14.12 L1 Lights OnCalibration Check AAAA,DDTest Pattern Control Mirror ControlCalibration Memory Test Camera Delay Factory Use onlyCamera Response Curves HistogramExit 31 Resolution Control Display Resolution ControlPage 32 Set Document Size Menu Document SizesCPU RAM RUN Self TestsRestore Nvram This page intentionally left blank Binary Filter Parameters Prompt Parameter Set A,B,C,D will appear IP Averager LUT Proceed With Calibration ? Y/N Autocalibration33 Scsi Buffer Parameters Menu Scsi Buffer ParametersThis page intentionally left blank Procedure for Issuing the Save Command Pixel Correction and Exposure ValuesSystem Parameters Page Procedure to Remove the Front Cover Procedure to Remove Either Side PanelProcedure to Remove the Back Panel Procedure for Replacing Belt and Adjusting Tension Procedure for Installing and Replacing Imaging Lamp Procedure for Replacing White Background Task -- Replacement of White BackgroundProcedure for Removing and Replacing Camera Assembly Task - Camera Assembly Removal and ReplacementTask -- Camera Calibration Procedure for Adjusting Video BoardExposure Calibration Camera Board OffsetGain Calibration +5 Volts Task - Checking and Adjusting Voltages+12 Volts Volts+120 Volts Procedure for Replacing Fans Task - FAN ReplacementTask - Filter Cleaning and Replacement II. Save the Setup Terminal SetupIII. Host Serial Connection Appendix B Replacement Parts List