IBM CF Series manual Major Systems of Scanner

Page 22

3.1 MAJOR SYSTEMS OF SCANNER

To provide a general overview of how the CF Series Scanner works, the remainder of this section will discuss the various systems that comprise the scanner.

3.1.1 Scanner Control System

The CF Series Scanner may be controlled by the host computer, by the optional keypad on the scanner itself, or a combination of the two.

Another option is the use of a separate "local terminal." Used primarily for diagnostic purposes, this ANSI-type terminal takes the place of the host computer. It is the only means of accessing the Diagnostics program.

Once initiated, the Central Processor (CPU) Board and the Camera Controller Board (CCB) control the functions of the CF Series Scanner for the most part.

1.The CPU Board controls the general operations of the electronics of the scanner, contains the firmware which operates the scanner, and other functions.

2.The Camera Controller Board (CCB) provides timing for all the other boards and handles the merging of the input data from the cameras. Other functions include setting the number of active cameras, the sequencing of the cameras, and document size. It also sends data from the scanner to the host or optional interface board in on-line scanning.

3.1.2 Document Transport System

The document transport system is comprised of a motor driver, a stepper motor, a set of pulleys, a set of belts, and two drive rollers. The Video Board controls the system. The motor driver operates a stepper motor. The stepper motor turns a set of pulleys connected by belts.

The belts turn two drive rollers located on the bed of the scanner, which move the document past the scan window.

1.The Video Board passes control signals to the motor driver and receives signals from the document sensors.

2.The motor driver translates the control signals it receives from the Video Board.

3.The bi-directional stepping motor drives the document transport system.

4.A set of pulleys reduces the rpms.

5.Two timing belts connect the pulleys.

Image 22
Contents CF Series Scanner Maintenance Manual Firmware Rev. S27G and up Scanner Serial NumberTrademark Notice Related Scangraphics Documentation PrefaceIf You Have Questions Table of Contents Connections ON-BOARD Diagnostic System Diagnostics Tests Saving Parameter Changes to NON-VOLATILE Memories  System Overview User Interface FeaturesMultiple Resolution Critical CalibrationDiagnostics ConstructionFunctional Specifications SpecificationsNominal Scan Speed/Resolution Chart Physical Specifications Input CharacteristicsPower Specifications Environmental Specifications This page intentionally left blank Installation Connections POWER-UP DE-INSTALLATION System Description Major Systems of Scanner Model # of Cameras Page Page This page intentionally left blank Monthly DailyAnnually Page On-Board Diagnostic System CF Series Scanner Main MenuPage This page intentionally left blank Set Global Parameters Global Parameters MenuPage Parameter Backup Perform System InitializationThis page intentionally left blank Set Motor Speed Set Motor Speed MenuPage Splice Counts Splice Count Listing Example from a CF 1000/44This page intentionally left blank Focus and Magnification Menu Focus and MagnificationEquipment, Tools & Materials Required This page intentionally left blank Focus Sample Focus DisplayPage Page This page intentionally left blank Magnification Procedure for Adjusting Camera Magnification Magnification Values for CF300 This page intentionally left blank IP LUT For the Image Processor Board Example of an Image Processor Board Look-Up Table IP LUT Merge and Splice Adjustment 17 Merge and Splice Adjustment MenuPage Page This page intentionally left blank Line Splice Adjustment Merge Adjustment Procedure for Adjusting Camera MergeAutosize Parameters 24 Set Autosize Parameters MenuSET CCB Registers a Test Frame Grabber BTest I/O Board C 26 I/O Board Test Menu27 I/O Board Sensor Test Offsets D 28 Page Offsets MenuThis page intentionally left blank Camera System Diagnostics E 29 Camera System StatisticsPage NE Normalize Exposure Gain Memory NG Normalize GainFill Calibration Memory Display Calibration MemoryTake Line Autotake Video Board Reset Not used 14.11 L0 Lights OffTake Qualified Line 14.12 L1 Lights OnAAAA,DD Calibration CheckMirror Control Test Pattern ControlCamera Response Curves Camera Delay Factory Use onlyCalibration Memory Test HistogramExit Resolution Control 31 Resolution Control DisplayPage Document Sizes 32 Set Document Size MenuRUN Self Tests CPU RAMRestore Nvram This page intentionally left blank Binary Filter Parameters Prompt Parameter Set A,B,C,D will appear IP Averager LUT Autocalibration Proceed With Calibration ? Y/NScsi Buffer Parameters 33 Scsi Buffer Parameters MenuThis page intentionally left blank Pixel Correction and Exposure Values Procedure for Issuing the Save CommandSystem Parameters Page Procedure to Remove Either Side Panel Procedure to Remove the Front CoverProcedure to Remove the Back Panel Procedure for Replacing Belt and Adjusting Tension Procedure for Installing and Replacing Imaging Lamp Task -- Replacement of White Background Procedure for Replacing White BackgroundTask - Camera Assembly Removal and Replacement Procedure for Removing and Replacing Camera AssemblyProcedure for Adjusting Video Board Task -- Camera CalibrationCamera Board Offset Exposure CalibrationGain Calibration +12 Volts Task - Checking and Adjusting Voltages+5 Volts Volts+120 Volts Task - FAN Replacement Procedure for Replacing FansTask - Filter Cleaning and Replacement Terminal Setup II. Save the SetupIII. Host Serial Connection Appendix B Replacement Parts List