5.1.10 SET CCB REGISTERS (A)

“Set CCB registers” allows you to view and alter the contents of the registers on the CCB (Camera Controller Board). These registers store the parameters controlling the function of the camera.

When you press <A> for “Set CCB Registers”, the prompt, “Do you want to initialize CCB Board? Type “Y” (yes), or “N” (No)-->,”appears.If you press <Y>, the registers will be cleared of their current and reset to the values stored on the Non-volatile RAM (NVRAM) on the CALS Board. If you press <N>, the current values will be retained until you change them or the scanner is turned off. In either case, the operative values will be displayed as shown in figure 5-25.

 

----- SET CCB REGISTERS -----

00

Expsr Timer

Low : FF

08

Expsr Timer High : FF

10

Camera Enables : 70

 

 

20

Merge 0: 00

 

 

21

Merge 1: 5E

22

Merge 2: 4D

 

 

23

Merge 3: 34

24

Merge 4: 5C

 

 

25

Merge 5: 10

26

Merge 6: 26

 

 

27

Merge 7: 7C

28

Merge 8: 80

 

 

29

Merge 9: 00

2A

Merge A: 00

 

 

2B

Merge B: 00

2C

Merge C: 00

 

 

2D

Merge D: 00

2E

Merge E: 00

 

 

2F

Merge F: 00

30

Window Start Low

: 18

34

Window Start High : 02

38

Window Width Low

: EA

3C

Window Width High : A1

40

Interface Status: 6F

50

CCB Control/Stat: 00

60

Int Cntrl(writeonly)

70

Line Scan Delay : 00

 

S = SET

X = EXIT

CHOICE =

 

 

 

 

 

Ready

 

 

 

 

 

 

 

Figure 5-25 Set CCB Registers Menu

5.1.11TEST FRAME GRABBER (B)

This option allows you to test the Frame Grabber section of the display board which creates the image seen on the display monitor. When you select this option, a pattern of boxes will fill the display of monitor so you can check the screen for squareness and centering. On the scanner control terminal, the prompt, “Hit any key to exit,” appears. Entering any key will return you to the Diagnostic Tests menu.

Image 59
Contents Firmware Rev. S27G and up Scanner Serial Number CF Series Scanner Maintenance ManualTrademark Notice Preface Related Scangraphics DocumentationIf You Have Questions Table of Contents Connections ON-BOARD Diagnostic System Diagnostics Tests Saving Parameter Changes to NON-VOLATILE Memories  System Overview Critical Calibration FeaturesMultiple Resolution User InterfaceConstruction DiagnosticsNominal Scan Speed/Resolution Chart SpecificationsFunctional Specifications Power Specifications Input CharacteristicsPhysical Specifications Environmental Specifications This page intentionally left blank Installation Connections POWER-UP DE-INSTALLATION System Description Major Systems of Scanner Model # of Cameras Page Page This page intentionally left blank Annually DailyMonthly Page CF Series Scanner Main Menu On-Board Diagnostic SystemPage This page intentionally left blank Global Parameters Menu Set Global ParametersPage Perform System Initialization Parameter BackupThis page intentionally left blank Set Motor Speed Menu Set Motor SpeedPage Splice Count Listing Example from a CF 1000/44 Splice CountsThis page intentionally left blank Equipment, Tools & Materials Required Focus and MagnificationFocus and Magnification Menu This page intentionally left blank Sample Focus Display FocusPage Page This page intentionally left blank Magnification Procedure for Adjusting Camera Magnification Magnification Values for CF300 This page intentionally left blank IP LUT For the Image Processor Board Example of an Image Processor Board Look-Up Table IP LUT 17 Merge and Splice Adjustment Menu Merge and Splice AdjustmentPage Page This page intentionally left blank Line Splice Adjustment Procedure for Adjusting Camera Merge Merge Adjustment24 Set Autosize Parameters Menu Autosize ParametersTest Frame Grabber B SET CCB Registers a26 I/O Board Test Menu Test I/O Board C27 I/O Board Sensor Test 28 Page Offsets Menu Offsets DThis page intentionally left blank 29 Camera System Statistics Camera System Diagnostics EPage NE Normalize Exposure NG Normalize Gain Gain MemoryTake Line Display Calibration MemoryFill Calibration Memory 14.12 L1 Lights On Video Board Reset Not used 14.11 L0 Lights OffTake Qualified Line AutotakeCalibration Check AAAA,DDTest Pattern Control Mirror ControlHistogram Camera Delay Factory Use onlyCalibration Memory Test Camera Response CurvesExit 31 Resolution Control Display Resolution ControlPage 32 Set Document Size Menu Document SizesCPU RAM RUN Self TestsRestore Nvram This page intentionally left blank Binary Filter Parameters Prompt Parameter Set A,B,C,D will appear IP Averager LUT Proceed With Calibration ? Y/N Autocalibration33 Scsi Buffer Parameters Menu Scsi Buffer ParametersThis page intentionally left blank System Parameters Procedure for Issuing the Save CommandPixel Correction and Exposure Values Page Procedure to Remove the Back Panel Procedure to Remove the Front CoverProcedure to Remove Either Side Panel Procedure for Replacing Belt and Adjusting Tension Procedure for Installing and Replacing Imaging Lamp Procedure for Replacing White Background Task -- Replacement of White BackgroundProcedure for Removing and Replacing Camera Assembly Task - Camera Assembly Removal and ReplacementTask -- Camera Calibration Procedure for Adjusting Video BoardExposure Calibration Camera Board OffsetGain Calibration Volts Task - Checking and Adjusting Voltages+5 Volts +12 Volts+120 Volts Procedure for Replacing Fans Task - FAN ReplacementTask - Filter Cleaning and Replacement II. Save the Setup Terminal SetupIII. Host Serial Connection Appendix B Replacement Parts List