5.1.15 (F) RESOLUTION CONTROL
The option is used to set scanning resolutions and their corresponding display strings. Resolutions are selected by a letter index
When you press <F> to select “Resolution Control”, the display on the screen will be similar to figure
|
| ||
RESOLUTION | PIXELS/INCH | DISPLAY STRING | DIVISOR |
A | 1000 | 1000 | 1.000 |
B | 800 | 800 | 1.250 |
C | 700 | 700 | 1.430 |
D | 600 | 600 | 1.665 |
E | 500 | 500 | 2.000 |
F | 400 | 400 | 2.500 |
G | 300 | 300 | 3.335 |
H | 200 | 200 | 5.000 |
| S : SET RESOLUTION | X : EXIT |
|
CHOICE : X
Figure 5-31 Resolution Control Display.
The Resolution Index
“Pixels/inch” is the number of pixels the scanner can resolve per inch.
“Display string” is the name you assign to each Resolution Index and it is display on the keypad display window as well as on the Main Menu of the local control terminal.
“Divisor” is the ratio of maximum resolution to scanning resolution. For example, a CF1000 scanner has a maximum resolution of 1000 pixels/inch. If scanning resolution is 500 pixels/per inch, the divisor is (1000.0)/(500.0) = 2.000. Calculate the required divisor values in this way before setting new resolutions.
If you press<X> for “Exit”, you will be returned to the Diagnostic Test menu.
If you press <S>, the prompt “Resolution” appears, enter a letter for the resolution you wish to set.