5.1.14 CAMERA SYSTEM DIAGNOSTICS (E)

When you press this option, a display similar to the one shown in figure 5-29 appears. The “n” shows the number of cameras set in Global parameters.

USING n CAMERAS

CAMERA SIZE (PIXELS) [1510] :

Figure 5-29 Camera System Statistics

Enter the camera size or just press <CR> and the menu in figure 5-30 appears.

==============================================================

E : EXPOSURE MEMORY

NE : NORMALIZE EXPOSURES

G : GAIN MEMORY

NG : NORMALIZE GAIN

D : DISPLAY CALIBRATION MEMORY

F : FILL CALIBRATION MEMORY

T : TAKE LINE

Q : TAKE QUALIFIED LINE

A : AUTOTAKE

V : VIDEO BOARD RESET

L0 : LIGHTS OFF

L1 : LIGHTS ON

U : UNIFORMITY CHECK

K : CALIBRATION CHECK

M : MIRROR CONTROL

P : TEST PATTERN CONTROL

Y : CAMERA DELAY

C : CALIBRATION MEMORY TEST

R : CAMERA RESPONSE CURVES

H : HISTOGRAM

X : EXIT

 

==============================================================

-

 

Ready

 

 

 

Figure 5-30 Camera System Diagnostics Menu

5.1.14.1 E: Exposure Memory

Exposure in the CF scanner is similar to shutter speed in a conventional camera. The higher the number (the slower shutter speed), the longer the camera is collecting data. This memory stores data telling the camera when to start collecting data. For Example, if you enter “2000” in hexadecimal, the camera starts collecting light reflected from the document and 2000 pixel times later, data is output from the camera.

If you enter <D> and <CR> for “Display”, the content of the Exposure Memory will be displayed, starting from address 0000. This memory contains 64k 8-bit words. They are displayed 320 at a time. To view the next 320, press <D> and <CR> again. To view the memory starting at an address other than 0000, enter D command, followed immediately by the address. You do not need a <CR>. For example, “D2000”.

If you choose <F> for “Fill”, you can fill the memory with a single hexadecimal number you specify. This value will fill the memory, writing over anything already there. If you want to

Image 64
Contents CF Series Scanner Maintenance Manual Firmware Rev. S27G and up Scanner Serial NumberTrademark Notice Related Scangraphics Documentation PrefaceIf You Have Questions Table of Contents Connections ON-BOARD Diagnostic System Diagnostics Tests Saving Parameter Changes to NON-VOLATILE Memories  System Overview Features Multiple ResolutionUser Interface Critical CalibrationDiagnostics ConstructionFunctional Specifications SpecificationsNominal Scan Speed/Resolution Chart Physical Specifications Input CharacteristicsPower Specifications Environmental Specifications This page intentionally left blank Installation Connections POWER-UP DE-INSTALLATION System Description Major Systems of Scanner Model # of Cameras Page Page This page intentionally left blank Monthly DailyAnnually Page On-Board Diagnostic System CF Series Scanner Main MenuPage This page intentionally left blank Set Global Parameters Global Parameters MenuPage Parameter Backup Perform System InitializationThis page intentionally left blank Set Motor Speed Set Motor Speed MenuPage Splice Counts Splice Count Listing Example from a CF 1000/44This page intentionally left blank Focus and Magnification Menu Focus and MagnificationEquipment, Tools & Materials Required This page intentionally left blank Focus Sample Focus DisplayPage Page This page intentionally left blank Magnification Procedure for Adjusting Camera Magnification Magnification Values for CF300 This page intentionally left blank IP LUT For the Image Processor Board Example of an Image Processor Board Look-Up Table IP LUT Merge and Splice Adjustment 17 Merge and Splice Adjustment MenuPage Page This page intentionally left blank Line Splice Adjustment Merge Adjustment Procedure for Adjusting Camera MergeAutosize Parameters 24 Set Autosize Parameters MenuSET CCB Registers a Test Frame Grabber BTest I/O Board C 26 I/O Board Test Menu27 I/O Board Sensor Test Offsets D 28 Page Offsets MenuThis page intentionally left blank Camera System Diagnostics E 29 Camera System StatisticsPage NE Normalize Exposure Gain Memory NG Normalize GainFill Calibration Memory Display Calibration MemoryTake Line Video Board Reset Not used 14.11 L0 Lights Off Take Qualified LineAutotake 14.12 L1 Lights OnAAAA,DD Calibration CheckMirror Control Test Pattern ControlCamera Delay Factory Use only Calibration Memory TestCamera Response Curves HistogramExit Resolution Control 31 Resolution Control DisplayPage Document Sizes 32 Set Document Size MenuRUN Self Tests CPU RAMRestore Nvram This page intentionally left blank Binary Filter Parameters Prompt Parameter Set A,B,C,D will appear IP Averager LUT Autocalibration Proceed With Calibration ? Y/NScsi Buffer Parameters 33 Scsi Buffer Parameters MenuThis page intentionally left blank Pixel Correction and Exposure Values Procedure for Issuing the Save CommandSystem Parameters Page Procedure to Remove Either Side Panel Procedure to Remove the Front CoverProcedure to Remove the Back Panel Procedure for Replacing Belt and Adjusting Tension Procedure for Installing and Replacing Imaging Lamp Task -- Replacement of White Background Procedure for Replacing White BackgroundTask - Camera Assembly Removal and Replacement Procedure for Removing and Replacing Camera AssemblyProcedure for Adjusting Video Board Task -- Camera CalibrationCamera Board Offset Exposure CalibrationGain Calibration Task - Checking and Adjusting Voltages +5 Volts+12 Volts Volts+120 Volts Task - FAN Replacement Procedure for Replacing FansTask - Filter Cleaning and Replacement Terminal Setup II. Save the SetupIII. Host Serial Connection Appendix B Replacement Parts List