Tripp Lite OMNIPRO owner manual Basic Operation, Optional Installation- Select models†, Switches

Page 4

–Optional Installation– (Select models)

OPTION 1 (Phone-Line Surge Suppression)

Using telephone cords, connect your wall jack to the UPS jack marked “LINE” (or “IN”). Connect your equipment to the UPS jack marked “EQUIP” (or “OUT”).

OPTION 2 (UPS Software)

Using Tripp Lite cable (if supplied), connect the DB9 port of your computer to the DB9 port of your UPS. Load software (if supplied) and run installation program appropriate for your operating system.

†Phone line and DB9 port connections are optional. Your UPS will function properly without these connections. Make sure the equipment you connect to the UPS’s telephone jacks is also protected against damaging surges on the AC line.

Basic Operation

Switches

OFF ON

With your UPS plugged in, set this switch according to the recommendations in Step 3 of the Quick Installation section. "ON" Position

Function: ENABLES battery backup. UPS Conditions: The UPS battery is charging. Power is ON at the UPS receptacles. The "" indicator light is illuminated. Setting Advantages: Provides battery backup during blackouts or brownouts.

"OFF" Position

Function: DISABLES battery backup. UPS Conditions: The UPS battery is charging. Power is ON at the UPS receptacles. The " " indicator light is illuminated. The " " indicator light is flashing. Setting Advantages: continues to charge the battery when power is present while turning OFF the inverter to prevent battery backup operation when equipment is not in use.

Note: Only UPS models equipped with a “MUTE/TEST” switch allow you to “cold start” them and use them as stand-alone power sources when utility power is not present. To “cold start” your UPS, first turn your UPS ON. Then, move the MUTE/TEST switch to the left, hold momentarily and release when the " " indicator light begins to flash.

Available on select models

Use this momentary switch to do two things: Silence the UPS alarm*

Move this switch to the left and release it. Note: When the battery is nearly depleted the alarm resumes (and cannot be silenced) to alert you to immediately shut down connected equipment.

*The UPS alarm consists of a series of short beeps followed by a brief pause. The alarm is activated when the UPS switches to battery during a blackout or brownout.

Test your UPS's battery charge**

Leave your connected equipment ON. With your UPS plugged in and turned ON, move this switch to the left; hold it there for 2 seconds and release it. The UPS will momentarily switch to battery to test its charge. If the UPS alarm sounds or the properly- sized load is not supported, let your UPS charge its batteries for 12 hours and repeat the test. If alarm still sounds, contact Tripp Lite for service. CAUTION: Do not unplug your UPS to test its batteries. This will remove safe electrical grounding and may introduce a damaging surge into your network connections.

4

**If your model is not equipped with this switch, you can still test your UPS batteries. First plug your UPS into a grounded surge suppressor (which will maintain the ground connection), then turn the surge suppressor's power switch OFF.

Image 4
Contents Quick Installation p Safety Battery WarningsUPS Location Warnings UPS Connection WarningsQuick Installation Set your UPS’s OFF on SwitchSwitches Optional Installation- Select models†Basic Operation Indicator Lights Other UPS FeaturesStorage & Service SpecificationsService StorageInstalación Rápida p Seguridad Advertencias Sobre la Ubicación del UPSAdvertencia Sobre las Conexiones del Sistema UPS Advertencias Sobre la Conexión del EquipoInstalación Rápida Instalación Opcional- Sólo algunos modelos† Operación BásicaInterruptores Luces Indicadoras Otras Características del UPSAlmacenamiento y servicio EspecificacionesAlmacenamiento ServicioTodos LOS Modelos Installation rapide p Emplacement de l’UPS Avertissements Consignes de sécuritéBranchement de l’UPS Avertissements Branchement du matériel AvertissementsInstallation rapide Positionner l’interrupteur « OFF on » de l’UPSFonctionnement Standard Installation facultative certains modèles uniquement†Interrupteurs Voyants Autres caractéristiques de l’UPSStockage et réparations Caractéristiques techniquesStockage RéparationsSchnellinstallation S Sicherheit Warnhinweise zur Aufstellung der USVWarnhinweise zum Anschluß der USV Warnhinweise zum GeräteanschlußSchnellinstallation Stellen Sie den „AUS-EIN-Schalter der USV einGrundlegende Bedienungshinweise `- Optionale Installation Bestimmte Modelle†Schalter Anzeigelampen Weitere USV-MerkmaleLagerung und Wartung Technische DatenLagerung WartungžØÎÏͽÜÐÎϽÊ˿ǽÎÅÎÏÂÉØÎÏÍ «¾ÂÎÌÂÔÂÊÅ ¾ÂÄË̽ÎÊËÎÏÅ žØÎÏͽÜÐÎϽÊ˿ǽÎÅÎÏÂÉØ «ÎÊË¿ÊØÂÌÍÅÊÓÅÌØÑÐÊÇÓÅËÊÅÍË¿½ÊÅÜÎÅÎÏÂÉØ ¿ÂÏË¿ØÂÅÊÁÅǽÏËÍØ ²Í½ÊÂÊÅÂÅ˾ÎÈÐÃÅ¿½ÊÅÂÎÅÎÏÂÉØ 280/175 450/280