CYV15G0404DXB
CYV15G0404DXB AC Electrical Characteristics
Parameter | Description | Min. | Max | Unit | ||
CYV15G0404DXB | Transmitter LVTTL Switching Characteristics Over the Operating Range |
|
| |||
fTS |
|
| TXCLKx Clock Cycle Frequency | 19.5 | 150 | MHz |
tTXCLK |
| TXCLKx Period=1/fTS | 6.66 | 51.28 | ns | |
tTXCLKH[20] | TXCLKx HIGH Time | 2.2 |
| ns | ||
tTXCLKL[20] | TXCLKx LOW Time | 2.2 |
| ns | ||
t |
| [20, 21, 22] | TXCLKx Rise Time | 0.2 | 1.7 | ns |
TXCLKR |
|
|
|
|
| |
t |
| [20, 21, 22] | TXCLKx Fall Time | 0.2 | 1.7 | ns |
TXCLKF |
|
|
|
|
| |
tTXDS |
|
| Transmit Data | 2.2 |
| ns |
tTXDH |
|
| Transmit Data Hold Time from TXCLKx↑ (TXCKSELx ≠ 0) | 1.0 |
| ns |
fTOS |
|
| TXCLKOx Clock Frequency = 1x or 2x REFCLKx Frequency | 19.5 | 150 | MHz |
tTXCLKO | TXCLKOx Period=1/fTOS | 6.66 | 51.28 | ns | ||
tTXCLKOD | TXCLKO Duty Cycle centered at 60% HIGH time | 0 | ns | |||
CYV15G0404DXB | Receiver LVTTL Switching Characteristics Over the Operating | Range |
|
| ||
fRS |
|
| RXCLKx± Clock Output Frequency | 9.75 | 150 | MHz |
tRXCLKP | RXCLKx± Period = 1/fRS | 6.66 | 102.56 | ns | ||
tRXCLKD | RXCLKx± Duty Cycle Centered at 50% (Full Rate and Half Rate when | +1.0 | ns | |||
|
|
| RXCKSELx = 0) |
|
|
|
tRXCLKR [20] | RXCLKx± Rise Time | 0.3 | 1.2 | ns | ||
tRXCLKF [20] | RXCLKx± Fall Time | 0.3 | 1.2 | ns | ||
t | [23] | Status and Data Valid Time to RXCLKx± (RXRATEx = 0, RXCKSELx = 0) |
| ns | ||
RXDv– |
|
| (Full Rate) |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Status and Data Valid Time to RXCLKx± (RXRATEx = 1, RXCKSELx = 0) |
| ns | |
|
|
| (Half Rate) |
|
|
|
t | [23] | Status and Data Valid Time to RXCLKx± (RXRATEx = 0, RXCKSELx = 0) |
| ns | ||
RXDv+ |
| (Full Rate) |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Status and Data Valid Time to RXCLKx± (RXRATEx = 1, RXCKSELx =0) |
| ns | |
|
|
| (Half Rate) |
|
|
|
CYV15G0404DXB | REFCLKx Switching Characteristics Over the Operating Range |
|
|
| ||
fREF |
|
| REFCLKx Clock Frequency | 19.5 | 150 | MHz |
tREFCLK | REFCLKx Period = 1/fREF | 6.6 | 51.28 | ns | ||
tREFH |
|
| REFCLKx HIGH Time (TXRATEx = 1)(Half Rate) | 5.9 |
| ns |
|
|
| REFCLKx HIGH Time (TXRATEx = 0)(Full Rate) | 2.9[20] |
| ns |
tREFL |
|
| REFCLKx LOW Time (TXRATEx = 1)(Half Rate) | 5.9 |
| ns |
|
|
| REFCLKx LOW Time (TXRATEx = 0)(Full Rate) | 2.9[20] |
| ns |
tREFD[25] | REFCLKx Duty Cycle | 30 | 70 | % | ||
tREFR [20, 21, 22] | REFCLKx Rise Time |
| 2 | ns | ||
tREFF[20, 21, 22] | REFCLKx Fall Time |
| 2 | ns |
Notes
20.Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.
21.The ratio of rise time to falling time must not vary by greater than 2:1.
22.For a given operating frequency, neither rise or fall specification can be greater than 20% of the
23.Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.
24.Receiver UI (Unit Interval) is calculated as 1/(fREF * 20) (when TXRATEx = 1) or 1/(fREF * 10) (when TXRATEx = 0). In an operating link this is equivalent to tB.
25.The duty cycle specification is a simultaneous condition with the tREFH and tREFL parameters. This means that at faster character rates the REFCLKx± duty cycle cannot be as large as
Document #: | Page 28 of 44 |