automatically resetting when the voltage drops back to 130 volts. If the incoming voltage drops below 90 volts, the T200 will shut down, automatically resetting when until the voltage returns to 95 volts.
FRONT PANEL CIRCUIT BREAKER
If the T200 experiences an incoming current in excess of 15A, the front panel circuit BREAKER will disconnect the mains power. To reset the BREAKER simply push it in.
USB OUTLETS
Two USB
EXTERNAL DC POWER-ON TRIGGER
This feature enables the remote
FRONT PANEL INDICATORS OF OUTLET STATUS
The blue LEDs provided on the front and rear panels of the T200 indicate status and timing of the SWITCHED, DELAYED,
LED DIMMER CONTROL
A retractable LED DIMMER control is located on the front panel. Rotating the control clockwise increases the LED’s brightness and counterclockwise rotation dims them. Please note; to comply with UL® standards, the LEDs can’t be turned off completely. To store the control, push it in until the locking mechanism engages. To release it, push it in.
POWER SWITCH
To prevent inadvertent turn on or turn off, the front panel POWER switch must be depressed for at least 2 seconds.
POLARITY IDENTIFICATION
Polarity Identification is provided to guarantee that the AC outlet the T200 is plugged into is wired correctly. The illumination of the blue POLARITY FAULT LED indicates that the White and Black AC wires of the outlet into which the T200 is connected are reversed.
DO NOT OPERATE YOUR T200 WITH A LINE PROBLEM. IF THE RED POLARITY FAULT LED DOES ! ILLUMINATE, DISCONNECT THE UNIT IMMEDIATELY. A LICENSED ELECTRICIAN WILL NEED TO
REPAIR THE FAULTY WIRING PRIOR TO RECONNECTING THE T200.
UL® Listings
Your T200 has been exhaustively tested by Underwriter’s Laboratory (UL®). This ensures the product is safe when operated according to these instructions. The T200 has been certified for:
UL 1449: Standard for Transient Voltage Surge Suppressors
UL 1363: Standard for Relocatable Power Taps
UL
UL 60950: Protection for DATA Processing equipment (RJ11 & RJ45)
UL1283: Electromagnetic Interference Filters for 50/60Hz equipment
6