A&D MC-30K, MC-10K manual Tael HK general, Singapore

Page 15

The tables below indicate the weighing capacity and the minimum display for each unit, depending on the balance model.

When a measurement unit other than gram is used, it is not possible to weight up to capacity of the balance because the display does not have sufficient digits.

Use the MC series balance within the values shown in the tables below.

 

 

 

MC-10K

 

Unit

 

 

 

Capacity

Gram

Minimum

 

 

 

 

 

display

 

 

 

 

 

Gram

10100 g

10100

g

0.001

Kilogram

10.1 kg

10100

g

0.000001

Ounce (Avoir)

197

OZ

5600

g

0.00005

Troy Ounce

199

OZt

6200

g

0.00005

Metric Carat

19500 ct

3900

g

0.005

Momme

1973 mom

7400

g

0.0005

Pennyweight

6494 dwt

10100

g

0.001

Grain (UK)

155866

GN

10100

g

0.02

Tael (HK general, Singapore)

198

TL

7500

g

0.00005

Tael (HK jewelry)

195

TL

7300

g

0.00005

Tael (Taiwan)

194

TL

7300

g

0.00005

Tael (China)

198

TL

6200

g

0.00005

Tola (India)

865 t

10100

g

0.0001

Messghal

1984

MS

9300

g

0.0005

 

 

 

 

 

 

 

 

MC-30K

 

Unit

 

 

 

Capacity

Gram

Minimum

 

 

 

 

 

display

 

 

 

 

 

Gram

31000 g

31000

g

0.01

Kilogram

31.0 kg

31000

g

0.00001

Ounce (Avoir)

1093

OZ

31000

g

0.0005

Troy Ounce

966

OZt

31000

g

0.0005

Metric Carat

155000 ct

31000

g

0.05

Momme

8266 mom

31000

g

0.005

Pennyweight

1933 dwt

31000

g

0.01

Grain (UK)

478403

GN

31000

g

0.2

Tael (HK general, Singapore)

820

TL

31000

g

0.0005

Tael (HK jewelry)

828

TL

31000

g

0.0005

Tael (Taiwan)

826

TL

31000

g

0.0005

Tael (China)

992

TL

31000

g

0.0005

Tola (India)

2657 t

31000

g

0.001

Messghal

6613

MS

31000

g

0.005

 

 

13

 

 

 

Image 15
Contents 1WMPD4002203A MC-10K MC-30KAll rights reserved This Manual and MarksContents 10-5 10-614-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 Features IntroductionAbout This Manual Compliance with the following Council Directives ComplianceTo keep waterproof Dustproof Unpacking And Installing The BalanceAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Earth Installing the BalanceBefore Use PrecautionsAfter Use During UsePower Supply Display Display Symbols And Key OperationKey When pressed and released When pressed and held Key OperationsWeighing Units Tael HK general, Singapore F1l Filter Used Display Selecting a Weighing Unit ModeWeighing Basic WeighingWhen Building into a System Weighing Speed Adjustment Self Check Function with Response Adjustment Balance during adjustmentDo not allow vibration or drafts to affect Calibration Calibration GroupTerms Automatic self calibration due to changes in temperature Automatic Self Calibration150 g ~ +0.159 g Calibration using the internal mass One-Touch CalibrationAbout the internal mass When the MC-10K is used Calibration Using an External WeightStep Confirm that there is nothing on the pan and press Calibration Test Using an External WeightPrint key...... To store the new weight value. Even if Remove Remove the weight from the pan Step Balance displaysCorrecting the Internal Mass Value Key Permit or Inhibit Function Switch And InitializationStep Press Key to display To cancel This operation, press KeyInitializing the Balance Step Press KeyDisplay and Operation Keys Check the settings and condition before changing parametersFunction Table Structure and Sequence of the Function TableDetails of the Function Table LO buzzer Data output modeCp fnc Cp-b BepDout ID number output TimeoutAK, Error code Time/Date outputF1-t ID number settingInternal mass correction F1-b Averaging range for First moving AverageStability band width 5t-b Zero upon power-on p-trDescription of the Class Environment, Display Condition CondAuto print modes a and B Description of the Item Data Output ModeKey mode Stream modeDP Dump print format 5if type Interval memory modeDescription of the Item Data Format Standard format 5if typeCSV format KF formatMT format NU numerical format 5if typeTare value Data numberDate TimeOverload Negative errorData Format Examples StableSetting the ID Number ID Number And GLP ReportDisplay character set Terminator, CR , LF or CR Calibration report using the internal massGLP Report Space, Ascii 20hCalibration report using an external weight Calibration test report using an external weightSignature Space, Ascii 20h Title block and end block OperationEnd block Sub 25 pin assignments Standard Input And Output InterfaceRS-232C and External Contact Input Sub 25 pin numbersRS-232C Terminals External contact inputOption Data output pause SettingsNot Auto print polarity NecessaryRsKey Using Windows Communication Tools Software WinCTUsing the WinCT software, the balance can do the following RsComCommand List CommandsAcknowledge Code and Error Codes Personal computer Time Balance Command Weighing mode Control Using CTS and RTSSettings Related to RS-232C CommandExtended Function Page Page Treatment of the Balance MaintenanceWeighing method TroubleshootingChecking the Balance Performance and Environment Checking that the balance performs properly16-2 Clock battery error Automatic response adjustment zero errorAutomatic response adjustment unstable error Internal errorAsking for Repair Other DisplaySpecifications Unit mm External DimensionsAD-8121B Printer AD-8922A Remote controllerOptions and Peripheral Instruments AX-MC10K/30KPAN Auto-centering PanData Logger Rechargeable BatteryFoot Switch Weighing Environment LoggerTerms Terms/IndexNothing is on the weighing pan Memory functionIndex Keys and symbolsFUl ErrorMode MT format F1lPage Instruments India Private Limited UK OfficeGerman Sales Office Korea Limited

MC-10K, MC-30K specifications

The A&D MC-30K and MC-10K are highly regarded weighing scales that cater to diverse industrial and commercial applications. Renowned for their accuracy, durability, and advanced technological features, these models are ideal for users who require precision in measurement.

The MC-30K model offers a capacity of up to 30 kilograms, while the MC-10K is designed for loads of up to 10 kilograms. Both models are equipped with high-resolution load cells that provide outstanding accuracy and stability in measurements. The readability of 1 gram for the MC-10K and 5 grams for the MC-30K ensures that even the smallest variations in weight are captured effectively, making them suitable for activities ranging from laboratory analysis to quality control in manufacturing processes.

One of the standout features of these scales is their easy-to-read LCD display, which allows users to view measurements clearly, even in low-light conditions. The display is designed to provide quick and efficient readouts, minimizing wait times during the weighing process.

Both the MC-30K and MC-10K models incorporate advanced technology, including automatic calibration and tare functions, which enhance usability and accuracy. The automatic calibration feature ensures that the scales maintain their precision over time, while the tare function allows users to weigh items in containers without needing to account for the container's weight separately.

Durability is another major characteristic of these scales. Built with robust materials, they are designed to withstand the rigors of daily use in busy environments. Additionally, their compact design ensures that they occupy minimal space, making them suitable for various settings, including laboratories, warehouses, and retail outlets.

Convenience is amplified with the inclusion of RS-232 interface options for seamless connectivity to computers or printers, enabling easy data collection and reporting. The power-saving features of both models, including auto-off functionality, contribute to longer battery life, reducing the need for frequent replacements.

In summary, the A&D MC-30K and MC-10K scales are exceptional tools for anyone needing reliable and precise weighing solutions. With their advanced features, user-friendly design, and durable construction, they stand out as top choices for industrial and commercial weighing applications.