A&D MC-10K manual UK Office, German Sales Office, Korea Limited, Instruments India Private Limited

Page 68

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo

170-0013 JAPAN

Telephone: [81] (3) 5391-6132

Fax: [81] (3) 5391-6148

A&D ENGINEERING, INC.

 

 

 

1756 Automation Parkway, San Jose, California

95131 U.S.A.

Telephone: [1] (408) 263-5333

Fax: [1] (408)263-0119

A&D INSTRUMENTS LIMITED

<UK Office>

 

Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire

OX14 1DY United Kingdom

 

 

 

Telephone: [44] (1235) 550420

Fax: [44] (1235) 550485

A&D INSTRUMENTS LIMITED

<German Sales Office>

Große Straße 13 b 22926 Ahrensburg Deutschland

Telefon: [49] (0) 4102 459230

Telefax: [49] (0) 4102 459231

A&D Australasia Pty Ltd.

 

 

 

32 Dew Street, Thebarton, South Australia

5031 AUSTRALIA

Telephone: [61] (8) 8301-8100

Fax: [61] (8) 8352-7409

A&D KOREA Limited

한국에이..()

대한민국 서울시 영등포구 여의도동 36-2

맨하탄 빌딩 8

( 8th Floor, Manhattan Bldg. 36-2 Yoido-dong, Youngdeungpo-ku, Seoul, KOREA )

전화: [82] (2) 780-4101

팩스: [82] (2) 782-4280

A&D RUS CO., LTD.

Компания ЭЙ энд ДИ РУС

121357, Российская Федерация, г.Москва, ул. Верейская, дом 17

( Bldg. 17, Vereyskaya st., Moscow, 121357 RUSSIAN FEDERATION )

тел.: [7] (495) 937-33-44

факс: [7] (495) 937-55-66

A&D Instruments India Private Limited

( 509, Udyog Vihar, Phase-, Gurgaon - 122 016, Haryana, India ) : 91-124-4715555 : 91-124-4715599

Image 68 Contents
MC-10K MC-30K 1WMPD4002203AThis Manual and Marks All rights reservedContents 14-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 10-510-6 About This Manual FeaturesIntroduction Compliance Compliance with the following Council DirectivesUnpacking And Installing The Balance To keep waterproof DustproofAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Installing the Balance EarthPrecautions Before UseDuring Use After UsePower Supply Display Symbols And Key Operation Key When pressed and released When pressed and heldKey Operations DisplayWeighing Units Tael HK general, Singapore Selecting a Weighing Unit Mode WeighingBasic Weighing F1l Filter Used DisplayWhen Building into a System Weighing Speed Adjustment Do not allow vibration or drafts to affect Self Check Function with Response AdjustmentBalance during adjustment Terms CalibrationCalibration Group 150 g ~ +0.159 g Automatic self calibration due to changes in temperatureAutomatic Self Calibration About the internal mass Calibration using the internal massOne-Touch Calibration Calibration Using an External Weight When the MC-10K is usedCalibration Test Using an External Weight Print key...... To store the new weight value. Even ifRemove Remove the weight from the pan Step Balance displays Step Confirm that there is nothing on the pan and pressCorrecting the Internal Mass Value Key Function Switch And Initialization Permit or InhibitTo cancel This operation, press Key Initializing the BalanceStep Press Key Step Press Key to displayCheck the settings and condition before changing parameters Function TableStructure and Sequence of the Function Table Display and Operation KeysDetails of the Function Table Data output mode Cp fnc Cp-bBep LO buzzerTimeout AK, Error codeTime/Date output Dout ID number outputID number setting Internal mass correctionF1-b Averaging range for First moving Average F1-tZero upon power-on p-tr Description of the Class Environment, DisplayCondition Cond Stability band width 5t-bDescription of the Item Data Output Mode Key modeStream mode Auto print modes a and BInterval memory mode Description of the Item Data FormatStandard format 5if type DP Dump print format 5if typeKF format MT formatNU numerical format 5if type CSV formatData number DateTime Tare valueNegative error Data Format ExamplesStable OverloadDisplay character set Setting the ID NumberID Number And GLP Report Calibration report using the internal mass GLP ReportSpace, Ascii 20h Terminator, CR , LF or CRSignature Space, Ascii 20h Calibration report using an external weightCalibration test report using an external weight End block Title block and end blockOperation Standard Input And Output Interface RS-232C and External Contact InputSub 25 pin numbers Sub 25 pin assignmentsOption RS-232C TerminalsExternal contact input Settings Not Auto print polarityNecessary Data output pauseUsing Windows Communication Tools Software WinCT Using the WinCT software, the balance can do the followingRsCom RsKeyCommands Command ListAcknowledge Code and Error Codes Control Using CTS and RTS Settings Related to RS-232CCommand Personal computer Time Balance Command Weighing modeExtended Function Page Page Maintenance Treatment of the BalanceTroubleshooting Checking the Balance Performance and EnvironmentChecking that the balance performs properly Weighing method16-2 Automatic response adjustment zero error Automatic response adjustment unstable errorInternal error Clock battery errorOther Display Asking for RepairSpecifications External Dimensions Unit mmAD-8922A Remote controller Options and Peripheral InstrumentsAX-MC10K/30KPAN Auto-centering Pan AD-8121B PrinterRechargeable Battery Foot SwitchWeighing Environment Logger Data LoggerTerms/Index Terms Memory function Nothing is on the weighing panKeys and symbols IndexError Mode MT formatF1l FUlPage UK Office German Sales OfficeKorea Limited Instruments India Private Limited