A&D MC-30K, MC-10K manual Display Symbols And Key Operation, Key Operations

Page 13
Enters the function table mode. Refer to "10. Function Table".
Performs weighing speed adjustment (response adjustment) and self check.
Displays other items of the calibration menu.
No function at the factory setting. By changing the function table:
Outputs "Title block" and "End block" for GLP report. Refer to "11-2. GLP Report ".
Displays the data memory menu.

4. Display Symbols And Key Operation

Key Operations

Key operation affects how the balance functions. The basic key operations are: "Press and release the key immediately" or "Press the key"

= normal key operation during measurement "Press and hold the key".

 

 

 

 

Displays the highest-order digit when placing a load of 10 kg

 

 

 

 

Display

 

 

 

or more on the MC-10K

 

 

 

Displays memory data information

 

 

 

 

 

 

 

Displays the weighing data relative to the weighing capacity

 

 

 

 

 

 

 

 

in percentage, in weighing mode. (Capacity indicator)

 

 

 

 

 

 

 

 

 

 

NET indicator

 

 

 

 

Weighing speed indicator (Response indicator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Animal mode indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processing indicator

 

Comparator indicators

Stabilization indicator

 

Units

Standby indicator

 

 

Interval memory

of power supply

 

 

 

Standby indicator

The current data number

 

Weighing data or

Processing indicator

 

stored data

 

 

Prior notice indicator

Blinking indicators

Interval memory,

of automatic self

 

 

active indicator

calibration

 

 

 

Each key, when pressed or when pressed and held, functions as follows:

Key

When pressed and released

When pressed and held

Turns the display ON and OFF. The standby indicator is displayed when the display is turned off. The weighing mode is enabled when the display is turned on. This key is available anytime. Pressing the key during operation will interrupt the operation and turn the display OFF.

In the weighing mode, turns the minimum weighing value ON and OFF.

In the counting or percent mode, enters the sampling mode.

No function at the factory setting. Switches the weighing units when units other than “g” are stored in the function setting.

Performs calibration using the internal mass.

Stores the weighing data in memory or outputs to a printer or personal computer depending on the function table settings. (Factory setting = output)

Sets the display to zero.

11

Image 13 Contents
1WMPD4002203A MC-10K MC-30KAll rights reserved This Manual and MarksContents 10-6 10-514-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 Introduction FeaturesAbout This Manual Compliance with the following Council Directives ComplianceTo keep waterproof Dustproof Unpacking And Installing The BalanceAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Earth Installing the BalanceBefore Use PrecautionsAfter Use During UsePower Supply Key When pressed and released When pressed and held Display Symbols And Key OperationKey Operations DisplayWeighing Units Tael HK general, Singapore Weighing Selecting a Weighing Unit ModeBasic Weighing F1l Filter Used DisplayWhen Building into a System Weighing Speed Adjustment Balance during adjustment Self Check Function with Response AdjustmentDo not allow vibration or drafts to affect Calibration Group CalibrationTerms Automatic Self Calibration Automatic self calibration due to changes in temperature150 g ~ +0.159 g One-Touch Calibration Calibration using the internal massAbout the internal mass When the MC-10K is used Calibration Using an External WeightPrint key...... To store the new weight value. Even if Calibration Test Using an External WeightRemove Remove the weight from the pan Step Balance displays Step Confirm that there is nothing on the pan and pressCorrecting the Internal Mass Value Key Permit or Inhibit Function Switch And InitializationInitializing the Balance To cancel This operation, press KeyStep Press Key Step Press Key to displayFunction Table Check the settings and condition before changing parametersStructure and Sequence of the Function Table Display and Operation KeysDetails of the Function Table Cp fnc Cp-b Data output modeBep LO buzzerAK, Error code TimeoutTime/Date output Dout ID number outputInternal mass correction ID number settingF1-b Averaging range for First moving Average F1-tDescription of the Class Environment, Display Zero upon power-on p-trCondition Cond Stability band width 5t-bKey mode Description of the Item Data Output ModeStream mode Auto print modes a and BDescription of the Item Data Format Interval memory modeStandard format 5if type DP Dump print format 5if typeMT format KF formatNU numerical format 5if type CSV formatDate Data numberTime Tare valueData Format Examples Negative errorStable OverloadID Number And GLP Report Setting the ID NumberDisplay character set GLP Report Calibration report using the internal massSpace, Ascii 20h Terminator, CR , LF or CRCalibration test report using an external weight Calibration report using an external weightSignature Space, Ascii 20h Operation Title block and end blockEnd block RS-232C and External Contact Input Standard Input And Output InterfaceSub 25 pin numbers Sub 25 pin assignmentsExternal contact input RS-232C TerminalsOption Not Auto print polarity SettingsNecessary Data output pauseUsing the WinCT software, the balance can do the following Using Windows Communication Tools Software WinCTRsCom RsKeyCommand List CommandsAcknowledge Code and Error Codes Settings Related to RS-232C Control Using CTS and RTSCommand Personal computer Time Balance Command Weighing modeExtended Function Page Page Treatment of the Balance MaintenanceChecking the Balance Performance and Environment TroubleshootingChecking that the balance performs properly Weighing method16-2 Automatic response adjustment unstable error Automatic response adjustment zero errorInternal error Clock battery errorAsking for Repair Other DisplaySpecifications Unit mm External DimensionsOptions and Peripheral Instruments AD-8922A Remote controllerAX-MC10K/30KPAN Auto-centering Pan AD-8121B PrinterFoot Switch Rechargeable BatteryWeighing Environment Logger Data LoggerTerms Terms/IndexNothing is on the weighing pan Memory functionIndex Keys and symbolsMode MT format ErrorF1l FUlPage German Sales Office UK OfficeKorea Limited Instruments India Private Limited