A&D MC-10K, MC-30K manual Compliance with the following Council Directives

Page 6

1-3. Compliance

1-3-1. Compliance with FCC Rules

Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when equipment is operated in a commercial environment. If this unit is operated in a residential area, it may cause some interference and under these circumstances the user would be required to take, at his own expense, whatever measures are necessary to eliminate the interference.

(FCC = Federal Communications Commission in the U.S.A.)

1-3-2.

Compliance with EMC Directives

 

This device features radio interference suppression and safety regulation in

 

compliance with the following Council Directives

Council directive 89/336/EEC

EN61326

EMC directive

Council directive 73/23/EEC

EN60950

Safety of Information Technology Equipment

The CE mark is an official mandatory European marking.

Please note that any electronic product must comply with local laws and regulations when sold or used anywhere outside Europe.

4

Image 6
Contents MC-10K MC-30K 1WMPD4002203AThis Manual and Marks All rights reservedContents 10-5 10-614-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 Features IntroductionAbout This Manual Compliance Compliance with the following Council DirectivesUnpacking And Installing The Balance To keep waterproof DustproofAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Installing the Balance EarthPrecautions Before UseDuring Use After UsePower Supply Key Operations Display Symbols And Key OperationKey When pressed and released When pressed and held DisplayWeighing Units Tael HK general, Singapore Basic Weighing Selecting a Weighing Unit ModeWeighing F1l Filter Used DisplayWhen Building into a System Weighing Speed Adjustment Self Check Function with Response Adjustment Balance during adjustmentDo not allow vibration or drafts to affect Calibration Calibration GroupTerms Automatic self calibration due to changes in temperature Automatic Self Calibration150 g ~ +0.159 g Calibration using the internal mass One-Touch CalibrationAbout the internal mass Calibration Using an External Weight When the MC-10K is usedRemove Remove the weight from the pan Step Balance displays Calibration Test Using an External WeightPrint key...... To store the new weight value. Even if Step Confirm that there is nothing on the pan and pressCorrecting the Internal Mass Value Key Function Switch And Initialization Permit or InhibitStep Press Key To cancel This operation, press KeyInitializing the Balance Step Press Key to displayStructure and Sequence of the Function Table Check the settings and condition before changing parametersFunction Table Display and Operation KeysDetails of the Function Table Bep Data output modeCp fnc Cp-b LO buzzerTime/Date output TimeoutAK, Error code Dout ID number outputF1-b Averaging range for First moving Average ID number settingInternal mass correction F1-tCondition Cond Zero upon power-on p-trDescription of the Class Environment, Display Stability band width 5t-bStream mode Description of the Item Data Output ModeKey mode Auto print modes a and BStandard format 5if type Interval memory modeDescription of the Item Data Format DP Dump print format 5if typeNU numerical format 5if type KF formatMT format CSV formatTime Data numberDate Tare valueStable Negative errorData Format Examples OverloadSetting the ID Number ID Number And GLP ReportDisplay character set Space, Ascii 20h Calibration report using the internal massGLP Report Terminator, CR , LF or CRCalibration report using an external weight Calibration test report using an external weightSignature Space, Ascii 20h Title block and end block OperationEnd block Sub 25 pin numbers Standard Input And Output InterfaceRS-232C and External Contact Input Sub 25 pin assignmentsRS-232C Terminals External contact inputOption Necessary SettingsNot Auto print polarity Data output pauseRsCom Using Windows Communication Tools Software WinCTUsing the WinCT software, the balance can do the following RsKeyCommands Command ListAcknowledge Code and Error Codes Command Control Using CTS and RTSSettings Related to RS-232C Personal computer Time Balance Command Weighing modeExtended Function Page Page Maintenance Treatment of the BalanceChecking that the balance performs properly TroubleshootingChecking the Balance Performance and Environment Weighing method16-2 Internal error Automatic response adjustment zero errorAutomatic response adjustment unstable error Clock battery errorOther Display Asking for RepairSpecifications External Dimensions Unit mmAX-MC10K/30KPAN Auto-centering Pan AD-8922A Remote controllerOptions and Peripheral Instruments AD-8121B PrinterWeighing Environment Logger Rechargeable BatteryFoot Switch Data LoggerTerms/Index TermsMemory function Nothing is on the weighing panKeys and symbols IndexF1l ErrorMode MT format FUlPage Korea Limited UK OfficeGerman Sales Office Instruments India Private Limited

MC-10K, MC-30K specifications

The A&D MC-30K and MC-10K are highly regarded weighing scales that cater to diverse industrial and commercial applications. Renowned for their accuracy, durability, and advanced technological features, these models are ideal for users who require precision in measurement.

The MC-30K model offers a capacity of up to 30 kilograms, while the MC-10K is designed for loads of up to 10 kilograms. Both models are equipped with high-resolution load cells that provide outstanding accuracy and stability in measurements. The readability of 1 gram for the MC-10K and 5 grams for the MC-30K ensures that even the smallest variations in weight are captured effectively, making them suitable for activities ranging from laboratory analysis to quality control in manufacturing processes.

One of the standout features of these scales is their easy-to-read LCD display, which allows users to view measurements clearly, even in low-light conditions. The display is designed to provide quick and efficient readouts, minimizing wait times during the weighing process.

Both the MC-30K and MC-10K models incorporate advanced technology, including automatic calibration and tare functions, which enhance usability and accuracy. The automatic calibration feature ensures that the scales maintain their precision over time, while the tare function allows users to weigh items in containers without needing to account for the container's weight separately.

Durability is another major characteristic of these scales. Built with robust materials, they are designed to withstand the rigors of daily use in busy environments. Additionally, their compact design ensures that they occupy minimal space, making them suitable for various settings, including laboratories, warehouses, and retail outlets.

Convenience is amplified with the inclusion of RS-232 interface options for seamless connectivity to computers or printers, enabling easy data collection and reporting. The power-saving features of both models, including auto-off functionality, contribute to longer battery life, reducing the need for frequent replacements.

In summary, the A&D MC-30K and MC-10K scales are exceptional tools for anyone needing reliable and precise weighing solutions. With their advanced features, user-friendly design, and durable construction, they stand out as top choices for industrial and commercial weighing applications.