A&D MC-10K Error, F1l, FUl, GX-04K GX-06K GX-07K GXK-012, IP-65 KF format, Mode MT format, Option

Page 66

erCd

AK, Error code

30

error 1

Stability error

54

error 2

Out of the setting range

54

error 6

Internal mass error

54

error 7

Internal mass error

54

Error code

.....................................................

54

Extended function

31, 49

External weight

18, 19, 61

- F -

 

 

f1l

Filter

14

FAST

.....................................................

16

fUl

Memory full

55

g5i

Capacity indicator

28

- G -

 

 

GX-04K

.....................................................

59

GX-06K

.....................................................

59

GX-07K

.................................................

8, 59

GXK-012

Animal weighing bowl

59

- H -

 

 

Hold

Hold function

28

- I -

 

 

id

ID number setting

31

ID Number

.....................................................

38

info

GLP output

30

int

Interval time

29

Internal mass

18

IP-65

.......................................................

8

- K -

 

 

KF format

.....................................................

35

- L -

 

 

lo

Sample mass error

54

- M -

 

 

Mass comparator

3, 6, 14, 28

MID.

..................................................... 16

mlt

Programmable-unit (Multi-unit).... 30

Mode

.....................................................

61

MT format

.....................................................

35

- N -

 

 

Numerical format

35

- O -

 

 

Option

.....................................................

59

- P -

 

 

p5

internal mass correction

............... 23

pnt

Decimal point

28

poff

Auto display-OFF

28

p-on

Auto display-ON

28

prt

Data output mode

29, 33, 44

pU5e

Data output pause

30, 44

- R -

 

 

Range

.....................................................

61

recend

End block

41

Repeatability

61

Re-zero

.....................................................

61

rng

Display at start

28

RsCom

.....................................................

45

RsKey

.....................................................

45

rtc

Clock battery error

55

RTS

.....................................................

48

- S -

 

 

5-id

ID number output

30, 44

5if

Serial interface

30

SLOW

.....................................................

16

Smart range function

61

Span calibration

15, 32

5pd

Display refresh rate

28

Stabilization time

62

Stable value

.....................................................

62

5tart

Title block

41

5t-b

Stability band width

28, 32

5-td

Time/Date output

30

Store

.....................................................

62

-T -

 

 

Tare

.....................................................

62

Target weight

18, 62

trc

Zero tracking

28

t-Up

Timeout

30

type

Data format

30, 44

- U -

 

 

Unit

Unit

31

- W -

 

 

WinCT

Communication Tools Software... 45

- Z -

 

 

Zero point

.....................................................

62

Zero upon power-on

15, 32

64

Image 66
Contents MC-10K MC-30K 1WMPD4002203AThis Manual and Marks All rights reservedContents 10-5 10-614-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 Features IntroductionAbout This Manual Compliance Compliance with the following Council DirectivesUnpacking And Installing The Balance To keep waterproof DustproofAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Installing the Balance EarthPrecautions Before UseDuring Use After UsePower Supply Key Operations Display Symbols And Key OperationKey When pressed and released When pressed and held DisplayWeighing Units Tael HK general, Singapore Basic Weighing Selecting a Weighing Unit ModeWeighing F1l Filter Used DisplayWhen Building into a System Weighing Speed Adjustment Self Check Function with Response Adjustment Balance during adjustmentDo not allow vibration or drafts to affect Calibration Calibration GroupTerms Automatic self calibration due to changes in temperature Automatic Self Calibration150 g ~ +0.159 g Calibration using the internal mass One-Touch CalibrationAbout the internal mass Calibration Using an External Weight When the MC-10K is usedRemove Remove the weight from the pan Step Balance displays Calibration Test Using an External WeightPrint key...... To store the new weight value. Even if Step Confirm that there is nothing on the pan and pressCorrecting the Internal Mass Value Key Function Switch And Initialization Permit or InhibitStep Press Key To cancel This operation, press KeyInitializing the Balance Step Press Key to displayStructure and Sequence of the Function Table Check the settings and condition before changing parametersFunction Table Display and Operation KeysDetails of the Function Table Bep Data output modeCp fnc Cp-b LO buzzerTime/Date output TimeoutAK, Error code Dout ID number outputF1-b Averaging range for First moving Average ID number settingInternal mass correction F1-tCondition Cond Zero upon power-on p-trDescription of the Class Environment, Display Stability band width 5t-bStream mode Description of the Item Data Output ModeKey mode Auto print modes a and BStandard format 5if type Interval memory modeDescription of the Item Data Format DP Dump print format 5if typeNU numerical format 5if type KF formatMT format CSV formatTime Data numberDate Tare valueStable Negative errorData Format Examples OverloadSetting the ID Number ID Number And GLP ReportDisplay character set Space, Ascii 20h Calibration report using the internal massGLP Report Terminator, CR , LF or CRCalibration report using an external weight Calibration test report using an external weightSignature Space, Ascii 20h Title block and end block OperationEnd block Sub 25 pin numbers Standard Input And Output InterfaceRS-232C and External Contact Input Sub 25 pin assignmentsRS-232C Terminals External contact inputOption Necessary SettingsNot Auto print polarity Data output pauseRsCom Using Windows Communication Tools Software WinCTUsing the WinCT software, the balance can do the following RsKeyCommands Command ListAcknowledge Code and Error Codes Command Control Using CTS and RTSSettings Related to RS-232C Personal computer Time Balance Command Weighing modeExtended Function Page Page Maintenance Treatment of the BalanceChecking that the balance performs properly TroubleshootingChecking the Balance Performance and Environment Weighing method16-2 Internal error Automatic response adjustment zero errorAutomatic response adjustment unstable error Clock battery errorOther Display Asking for RepairSpecifications External Dimensions Unit mmAX-MC10K/30KPAN Auto-centering Pan AD-8922A Remote controllerOptions and Peripheral Instruments AD-8121B PrinterWeighing Environment Logger Rechargeable BatteryFoot Switch Data LoggerTerms/Index TermsMemory function Nothing is on the weighing panKeys and symbols IndexF1l ErrorMode MT format FUlPage Korea Limited UK OfficeGerman Sales Office Instruments India Private Limited

MC-10K, MC-30K specifications

The A&D MC-30K and MC-10K are highly regarded weighing scales that cater to diverse industrial and commercial applications. Renowned for their accuracy, durability, and advanced technological features, these models are ideal for users who require precision in measurement.

The MC-30K model offers a capacity of up to 30 kilograms, while the MC-10K is designed for loads of up to 10 kilograms. Both models are equipped with high-resolution load cells that provide outstanding accuracy and stability in measurements. The readability of 1 gram for the MC-10K and 5 grams for the MC-30K ensures that even the smallest variations in weight are captured effectively, making them suitable for activities ranging from laboratory analysis to quality control in manufacturing processes.

One of the standout features of these scales is their easy-to-read LCD display, which allows users to view measurements clearly, even in low-light conditions. The display is designed to provide quick and efficient readouts, minimizing wait times during the weighing process.

Both the MC-30K and MC-10K models incorporate advanced technology, including automatic calibration and tare functions, which enhance usability and accuracy. The automatic calibration feature ensures that the scales maintain their precision over time, while the tare function allows users to weigh items in containers without needing to account for the container's weight separately.

Durability is another major characteristic of these scales. Built with robust materials, they are designed to withstand the rigors of daily use in busy environments. Additionally, their compact design ensures that they occupy minimal space, making them suitable for various settings, including laboratories, warehouses, and retail outlets.

Convenience is amplified with the inclusion of RS-232 interface options for seamless connectivity to computers or printers, enabling easy data collection and reporting. The power-saving features of both models, including auto-off functionality, contribute to longer battery life, reducing the need for frequent replacements.

In summary, the A&D MC-30K and MC-10K scales are exceptional tools for anyone needing reliable and precise weighing solutions. With their advanced features, user-friendly design, and durable construction, they stand out as top choices for industrial and commercial weighing applications.