A&D MC-10K, MC-30K manual Other Display, Asking for Repair

Page 58

Display

Error code

Description

 

 

 

 

 

Timeout error

 

EC,E03

If the timeout parameter is set to "t-Up1", the balance did not

 

receive the next character of a command within the time limit

 

 

 

 

of one second. Confirm the communication.

 

EC,E04

Excess characters error

 

The balance received excessive characters in a command.

 

 

Confirm the command.

 

 

Format error

 

EC,E06

A command includes incorrect data.

 

Example:

 

 

The data is numerically incorrect.

 

 

Confirm the command.

 

EC,E07

Parameter setting error

 

The received data exceeds the range that the balance can

 

 

accept. Confirm the parameter range of the command.

Other error code

 

If an error described above can not be released or other

 

errors are displayed, contact the local A&D dealer.

 

 

16-3. Other Display

When this indicator blinks, automatic self calibration is required. The indicator blinks when the balance detects changes in ambient temperature. If the balance is not used for several minutes with this indicator blinking, the balance performs automatic self calibration. The blinking period depends on the operating environment.

Advise The balance can be used while this indicator is blinking. We recommend that you perform automatic self calibration for precision weighing.

16-4. Asking for Repair

If the balance needs service or repair, contact your local A&D dealer.

The balance is a precision instrument. Use much care when handling the balance and observe the following when transporting the balance.

Use the original packing material for transportation.

Remove the draft gate, weighing pan and pan support from the main unit before placing the balance in the shipping container.

56

Image 58
Contents MC-10K MC-30K 1WMPD4002203AThis Manual and Marks All rights reservedContents 10-6 10-514-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 Introduction FeaturesAbout This Manual Compliance Compliance with the following Council DirectivesUnpacking And Installing The Balance To keep waterproof DustproofAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Installing the Balance EarthPrecautions Before UseDuring Use After UsePower Supply Key Operations Display Symbols And Key OperationKey When pressed and released When pressed and held DisplayWeighing Units Tael HK general, Singapore Basic Weighing Selecting a Weighing Unit ModeWeighing F1l Filter Used DisplayWhen Building into a System Weighing Speed Adjustment Balance during adjustment Self Check Function with Response AdjustmentDo not allow vibration or drafts to affect Calibration Group CalibrationTerms Automatic Self Calibration Automatic self calibration due to changes in temperature150 g ~ +0.159 g One-Touch Calibration Calibration using the internal massAbout the internal mass Calibration Using an External Weight When the MC-10K is usedRemove Remove the weight from the pan Step Balance displays Calibration Test Using an External WeightPrint key...... To store the new weight value. Even if Step Confirm that there is nothing on the pan and pressCorrecting the Internal Mass Value Key Function Switch And Initialization Permit or InhibitStep Press Key To cancel This operation, press KeyInitializing the Balance Step Press Key to displayStructure and Sequence of the Function Table Check the settings and condition before changing parametersFunction Table Display and Operation KeysDetails of the Function Table Bep Data output modeCp fnc Cp-b LO buzzerTime/Date output TimeoutAK, Error code Dout ID number outputF1-b Averaging range for First moving Average ID number settingInternal mass correction F1-tCondition Cond Zero upon power-on p-trDescription of the Class Environment, Display Stability band width 5t-bStream mode Description of the Item Data Output ModeKey mode Auto print modes a and BStandard format 5if type Interval memory modeDescription of the Item Data Format DP Dump print format 5if typeNU numerical format 5if type KF formatMT format CSV formatTime Data numberDate Tare valueStable Negative errorData Format Examples OverloadID Number And GLP Report Setting the ID NumberDisplay character set Space, Ascii 20h Calibration report using the internal massGLP Report Terminator, CR , LF or CRCalibration test report using an external weight Calibration report using an external weightSignature Space, Ascii 20h Operation Title block and end blockEnd block Sub 25 pin numbers Standard Input And Output InterfaceRS-232C and External Contact Input Sub 25 pin assignmentsExternal contact input RS-232C TerminalsOption Necessary SettingsNot Auto print polarity Data output pauseRsCom Using Windows Communication Tools Software WinCTUsing the WinCT software, the balance can do the following RsKeyCommands Command ListAcknowledge Code and Error Codes Command Control Using CTS and RTSSettings Related to RS-232C Personal computer Time Balance Command Weighing modeExtended Function Page Page Maintenance Treatment of the BalanceChecking that the balance performs properly TroubleshootingChecking the Balance Performance and Environment Weighing method16-2 Internal error Automatic response adjustment zero errorAutomatic response adjustment unstable error Clock battery errorOther Display Asking for RepairSpecifications External Dimensions Unit mmAX-MC10K/30KPAN Auto-centering Pan AD-8922A Remote controllerOptions and Peripheral Instruments AD-8121B PrinterWeighing Environment Logger Rechargeable BatteryFoot Switch Data LoggerTerms/Index TermsMemory function Nothing is on the weighing panKeys and symbols IndexF1l ErrorMode MT format FUlPage Korea Limited UK OfficeGerman Sales Office Instruments India Private Limited

MC-10K, MC-30K specifications

The A&D MC-30K and MC-10K are highly regarded weighing scales that cater to diverse industrial and commercial applications. Renowned for their accuracy, durability, and advanced technological features, these models are ideal for users who require precision in measurement.

The MC-30K model offers a capacity of up to 30 kilograms, while the MC-10K is designed for loads of up to 10 kilograms. Both models are equipped with high-resolution load cells that provide outstanding accuracy and stability in measurements. The readability of 1 gram for the MC-10K and 5 grams for the MC-30K ensures that even the smallest variations in weight are captured effectively, making them suitable for activities ranging from laboratory analysis to quality control in manufacturing processes.

One of the standout features of these scales is their easy-to-read LCD display, which allows users to view measurements clearly, even in low-light conditions. The display is designed to provide quick and efficient readouts, minimizing wait times during the weighing process.

Both the MC-30K and MC-10K models incorporate advanced technology, including automatic calibration and tare functions, which enhance usability and accuracy. The automatic calibration feature ensures that the scales maintain their precision over time, while the tare function allows users to weigh items in containers without needing to account for the container's weight separately.

Durability is another major characteristic of these scales. Built with robust materials, they are designed to withstand the rigors of daily use in busy environments. Additionally, their compact design ensures that they occupy minimal space, making them suitable for various settings, including laboratories, warehouses, and retail outlets.

Convenience is amplified with the inclusion of RS-232 interface options for seamless connectivity to computers or printers, enabling easy data collection and reporting. The power-saving features of both models, including auto-off functionality, contribute to longer battery life, reducing the need for frequent replacements.

In summary, the A&D MC-30K and MC-10K scales are exceptional tools for anyone needing reliable and precise weighing solutions. With their advanced features, user-friendly design, and durable construction, they stand out as top choices for industrial and commercial weighing applications.