A&D MC-30K, MC-10K manual Introduction, About This Manual, Features

Page 5

1. Introduction

This manual describes how the MC Series Mass Comparator Balances, MC-10K and MC-30K, work and how to get the most out of them in terms of performance.

Read this manual thoroughly before using the balance and keep it at hand for future reference.

For other functions and operations that this manual does not describe, refer to the GX-K series instruction manual.

1-1. About This Manual

This manual consists of the following five parts:

Basic operation

Describes precautions, the balance's construction and basic

 

operation.

Adapting to the environment ....

Describes response (and stability) adjustment to adapt to

 

the environment where there is vibration or drafts, the way to

 

maintain weighing precision in a variation of ambient

 

temperature, calibration and calibration test.

Selecting functions

Describes functions of the balance.

Interface and communication ... Describes the RS-232C serial interface and external contact input. The RS-232C serial interface can communicate with a computer that requests weighing data and controls the balance. This RS-232C interface is for use with a computer or printer. The external contact input commands the balance re-zeroing and data output.

Maintenance

Describes maintenance, error codes, troubleshooting,

 

specifications and options.

1-2. Features

Display resolution, one digit greater than a standard balance. This allows management of OIML class F1 or lower weights.

Capable of weighing small amounts of powdery or liquid material, even with a massive tare.

When used as a mass comparator, the balance can achieve even more precise weighing, by using the optional auto-centering pan (sold separately), which reduces eccentric loading errors.

3

Image 5
Contents 1WMPD4002203A MC-10K MC-30KAll rights reserved This Manual and MarksContents 14-1-1 Averaging Range f1-b and Averaging Time f1-t 14-1-2 10-510-6 About This Manual FeaturesIntroduction Compliance with the following Council Directives ComplianceTo keep waterproof Dustproof Unpacking And Installing The BalanceAuto-centering Pan AX-MC10K/30KPAN Installation Procedure Earth Installing the BalanceBefore Use PrecautionsAfter Use During UsePower Supply Key When pressed and released When pressed and held Display Symbols And Key OperationKey Operations DisplayWeighing Units Tael HK general, Singapore Weighing Selecting a Weighing Unit ModeBasic Weighing F1l Filter Used DisplayWhen Building into a System Weighing Speed Adjustment Do not allow vibration or drafts to affect Self Check Function with Response AdjustmentBalance during adjustment Terms CalibrationCalibration Group 150 g ~ +0.159 g Automatic self calibration due to changes in temperatureAutomatic Self Calibration About the internal mass Calibration using the internal massOne-Touch Calibration When the MC-10K is used Calibration Using an External WeightPrint key...... To store the new weight value. Even if Calibration Test Using an External WeightRemove Remove the weight from the pan Step Balance displays Step Confirm that there is nothing on the pan and pressCorrecting the Internal Mass Value Key Permit or Inhibit Function Switch And InitializationInitializing the Balance To cancel This operation, press KeyStep Press Key Step Press Key to displayFunction Table Check the settings and condition before changing parametersStructure and Sequence of the Function Table Display and Operation KeysDetails of the Function Table Cp fnc Cp-b Data output modeBep LO buzzerAK, Error code TimeoutTime/Date output Dout ID number outputInternal mass correction ID number settingF1-b Averaging range for First moving Average F1-tDescription of the Class Environment, Display Zero upon power-on p-trCondition Cond Stability band width 5t-bKey mode Description of the Item Data Output ModeStream mode Auto print modes a and BDescription of the Item Data Format Interval memory modeStandard format 5if type DP Dump print format 5if typeMT format KF formatNU numerical format 5if type CSV formatDate Data numberTime Tare valueData Format Examples Negative errorStable OverloadDisplay character set Setting the ID NumberID Number And GLP Report GLP Report Calibration report using the internal massSpace, Ascii 20h Terminator, CR , LF or CRSignature Space, Ascii 20h Calibration report using an external weightCalibration test report using an external weight End block Title block and end blockOperation RS-232C and External Contact Input Standard Input And Output InterfaceSub 25 pin numbers Sub 25 pin assignmentsOption RS-232C TerminalsExternal contact input Not Auto print polarity SettingsNecessary Data output pauseUsing the WinCT software, the balance can do the following Using Windows Communication Tools Software WinCTRsCom RsKeyCommand List CommandsAcknowledge Code and Error Codes Settings Related to RS-232C Control Using CTS and RTSCommand Personal computer Time Balance Command Weighing modeExtended Function Page Page Treatment of the Balance MaintenanceChecking the Balance Performance and Environment TroubleshootingChecking that the balance performs properly Weighing method16-2 Automatic response adjustment unstable error Automatic response adjustment zero errorInternal error Clock battery errorAsking for Repair Other DisplaySpecifications Unit mm External DimensionsOptions and Peripheral Instruments AD-8922A Remote controllerAX-MC10K/30KPAN Auto-centering Pan AD-8121B PrinterFoot Switch Rechargeable BatteryWeighing Environment Logger Data LoggerTerms Terms/IndexNothing is on the weighing pan Memory functionIndex Keys and symbolsMode MT format ErrorF1l FUlPage German Sales Office UK OfficeKorea Limited Instruments India Private Limited

MC-10K, MC-30K specifications

The A&D MC-30K and MC-10K are highly regarded weighing scales that cater to diverse industrial and commercial applications. Renowned for their accuracy, durability, and advanced technological features, these models are ideal for users who require precision in measurement.

The MC-30K model offers a capacity of up to 30 kilograms, while the MC-10K is designed for loads of up to 10 kilograms. Both models are equipped with high-resolution load cells that provide outstanding accuracy and stability in measurements. The readability of 1 gram for the MC-10K and 5 grams for the MC-30K ensures that even the smallest variations in weight are captured effectively, making them suitable for activities ranging from laboratory analysis to quality control in manufacturing processes.

One of the standout features of these scales is their easy-to-read LCD display, which allows users to view measurements clearly, even in low-light conditions. The display is designed to provide quick and efficient readouts, minimizing wait times during the weighing process.

Both the MC-30K and MC-10K models incorporate advanced technology, including automatic calibration and tare functions, which enhance usability and accuracy. The automatic calibration feature ensures that the scales maintain their precision over time, while the tare function allows users to weigh items in containers without needing to account for the container's weight separately.

Durability is another major characteristic of these scales. Built with robust materials, they are designed to withstand the rigors of daily use in busy environments. Additionally, their compact design ensures that they occupy minimal space, making them suitable for various settings, including laboratories, warehouses, and retail outlets.

Convenience is amplified with the inclusion of RS-232 interface options for seamless connectivity to computers or printers, enabling easy data collection and reporting. The power-saving features of both models, including auto-off functionality, contribute to longer battery life, reducing the need for frequent replacements.

In summary, the A&D MC-30K and MC-10K scales are exceptional tools for anyone needing reliable and precise weighing solutions. With their advanced features, user-friendly design, and durable construction, they stand out as top choices for industrial and commercial weighing applications.