64Chapter 10 Troubleshooting
If there is no response, this indicates that CallPilot 150 is not functioning. Refer to “CallPilot Mini/CallPilot 150 does not function at all” on page 64.
If CallPilot 150 responds with the appropriate prompt, there is a communication problem on the serial port. Continue with the steps in this procedure until you find the problem.
2Ensure the
3Check the
4Reset the terminal (or terminal emulation software).
5On the
•pin 2 - pin 2
•pin 3 - pin 3
•pin 7 - pin 7
If any check fails, replace the cable.
6Use a different terminal.
7If there is still a problem, reboot the CallPilot Mini/CallPilot 150 system. If there is no improvement call your support line.
CallPilot Mini/CallPilot 150 does not function at all
CallPilot Mini/CallPilot 150 is not functioning when there is no response from the terminal, or the Feature Codes do not appear on the telephone display.
1Check the LEDs.
If LED 1 is blinking quickly, the Bootloader has encountered an error. Check that the Feature Cartridge is installed in the bottom PCMCIA slot.
If LED 1 and LED 2 are blinking quickly, the
2Make sure that no one is logged into the Norstar Remote Utilities application. If someone is, have the person exit from Norstar Remote Utilities and then restart CallPilot 150. After CallPilot 150 has started up, the person can start Norstar Remote Utilities again.
Note: If you are troubleshooting a CallPilot Mini, skip step 2.
3Check to ensure the:
•TCM port is connected to the CallPilot Mini/CallPilot 150
•the Power Indicator light is lit
•power supply cord is plugged into the AC socket