If your computer has a modem with one telephone cable connector, you need to use a telephone line splitter. To connect the line splitter:

1Disconnect the telephone line for the modem from the wall outlet.

2Insert the line splitter into the wall outlet.

3Connect the telephone line for the modem to one of the connectors on the line splitter.

4Connect the telephone line for the telephone to the other connector on the line splitter.

Creating a Dial-Up Networking connection

You require a Dial-Up Networking connection to access the CallPilot modem. This connection must be configured for Operator assisted or manual dialing.

Note: If Dial-Up Networking is not installed on your computer, you must install it before you can proceed. Refer to the documentation that came with your Windows operating system for instruction on how to install Dial-Up Networking.

Creating a Dial-Up Networking connection on Windows 95 or Windows 98

1Click the Start button and then click Programs.

2Click Accessories and then click Communications.

3Click Dial-Up Networking.

The Dial-Up Networking window appears.

4Double click the Make New Connection icon.

5In the Type a name for the computer you are dialing box, enter a name for the CallPilot connection.

6From the Select a modem drop list, click the modem you are going to use for this connection.

7Click the Configure button.

8Click the Options tab.

9Select the Operator assisted or manual dialing option and then click the OK button.

10Click the Next button.

11Enter the telephone number and area code of the CallPilot system.

12Click the Finish button.

Configuring the Dial-Up Networking TCP/IP parameters on Windows 95 or Windows 98

1Right click the Dial-Up Networking connection you created for the CallPilot system and then click Properties.

2Click the Server Type tab.

P0990474 03

Image 72
Contents CallPilot Mini/CallPilot Installation and Maintenance Guide Copyright 2001 Nortel Networks TrademarksStatement of conditions Regulatory RequirementsContents Chapter Language Configuration Utility Chapter Upgrading CallPilot Mini/CallPilot 150 Appendix B Norstar Directory Numbers Figures P0990474 Tables P0990474 Preface Before you beginText conventions Example Group lists? YAbout the buttons on your telephone Related publicationsPreface Telephone buttonsHow to Get Help USA and CanadaEmea Europe, Middle East, Africa Cala Caribbean & Latin America Apac Asia PacificChapter How to use this guide How to use this guideHow to use this guide How the instructions are presentedFeatures of CallPilot Chapter System overviewAbout CallPilot Mini/CallPilot CallPilot Mini offersData connectors CompatibilityHardware overview Meridian 1 systems compatible with CallPilot MiniDimensions Pcmcia slotsPower Voice message storageChapter Preparing to install the CallPilot Mini/CallPilot Electrical serviceEnvironment Opening the kitUsing a LAN Preparing to install the CallPilot Mini/CallPilotManaging the CallPilot system Running without a LANChapter Installing CallPilot Mini/CallPilot Wall mounting the CallPilot Mini/CallPilotConnecting the CallPilot Mini/CallPilot Installing CallPilot Mini/CallPilotPort a and Port B Pinouts Installing CallPilot Mini/CallPilot 150 Connecting the EMC Kit to the CallPilot Mini cables P0990474 CallPilot Mini/CallPilot 150 LEDs LEDs during startupLEDs during operation Installing CallPilot Mini/CallPilot P0990474 Chapter Initializing the CallPilot Mini/CallPilot About CallPilot ManagerConfiguring the Meridian 1 PBX to work with CallPilot Mini Creating an ACD QueueInitializing the CallPilot Mini/CallPilot Initializing the CallPilot Mini/CallPilot 150 Creating an ACD Queue, stepAssigning ACD Agents Assigning ACD AgentsEnabling the Call Forward on Busy message Scheduled Block SCBComputer requirements for CallPilot Manager Computer requirementsBrowser requirements Connecting to the CallPilot Mini/CallPilot Changing the IP address using a serial cableCallPilot Mini/CallPilot 150 serial port CallPilot Mini/CallPilot 150 serial port pinoutPress the Enter key Changing the IP address using an Ethernet crossover cable Ethernet crossover cableRunning the Quick Install Wizard Quick Install Wizard parameters for a CallPilot MiniService to those mailboxes Quick Install Wizard parameters for a CallPilot Default is North America Initializing CallPilot 150 using a telephone Determining CallPilot 150 Feature CodesAssigned Feature Codes Feature Code name Default Number Configuring the CallPilot 150 initial parameters CallCenterRetryok Initializing the CallPilot Mini/CallPilot P0990474 Chapter Language Configuration Utility Changing the languages availableClick the Specify the language to remove drop list Language Configuration Utility Chapter Password administration Resetting passwordsResetting the system administrator password Resetting the password using a telephone CallPilot 150 onlyResetting the operator password CallPilot 150 only Resetting the password using CallPilot ManagerResetting the password using a telephone Password administrationResetting the Mailbox passwords Resetting the Modem access password Click the Access Passwords linkInstalling the CallPilot Backup and Restore Utility Chapter Backing up and restoring CallPilotBacking up the CallPilot information Backing up and restoring CallPilot Type of CallPilot system Maximum disk space requiredRestoring the CallPilot information Backing up and restoring CallPilot Retrieving the CallPilot log files Backing up and restoring CallPilot P0990474 Chapter Upgrading CallPilot Mini/CallPilot Upgrading the CallPilot software versionUpgrading the message storage Upgrading CallPilot Mini/CallPilotUpgrading CallPilot Mini/CallPilot 150 Upgrading CallPilot Mini/CallPilot P0990474 Chapter Troubleshooting Diagnosing problemsIntroduction Troubleshooting CallPilot Mini/CallPilot 150 does not function at allPower-on Diagnostics fail Cannot access CallPilot ManagerCallPilot Mini/CallPilot 150 fails during a start up All of the mailboxes disappear after a software upgrade CallPilot 150 Feature Codes are inactiveTo remove Feature Codes CallPilot 150 does not reboot following **STARTUP Inactive feature LED error messagesLED 1 is blinking quickly LED 1 and LED 2 are blinking quicklyTroubleshooting P0990474 Appendix a Modem Access Configuring your computer to access the CallPilot modemConnecting a telephone to your computer modem Modem Access Creating a Dial-Up Networking connectionCreating a Dial-Up Networking connection on Windows NT Advanced options box, select the Log on to network optionNetBEUI IPX/SPC Compatible Select the Specify an IP address optionSelect the Enable hardware flow control option Select the Use the following IP address optionCreating a Dial-Up Networking connection on Windows Select the Always use the following IP Address optionSelect the Advanced custom settings option Select the Allow these protocols optionNegotiate multi-link for single link connections Select the Internet Protocol TCP/IP optionInstalling the Nortel Networks Modem Configuration Utility Open the Modem Configuration Utility folderEnabling Modem access using CallPilot Manager Enabling Modem access using a telephone CallPilot 150 onlyEnabling the modem on the CallPilot Mini/CallPilot Modem accessY Connecting to the CallPilot system Configuring your modem to access the CallPilot modemConnecting to the CallPilot modem Tip Enter Telnet 192.168.0.2 and click OKAccessing the CallPilot system using CallPilot Manager Configuring your modem for normal modem connectionsAppendix B Norstar Directory Numbers Non-expanded Modular ICS DNsModular ICS 2-port cartridge DNs Modular ICS 6-port cartridge DNsProgramming CallPilot 150 DNs to memory buttons Norstar Directory NumbersGlossary Glossary Physical components of a CallPilot Mini/CallPilot Storage place for messages on CallPilot Push button telephone that emits Dtmf tones Glossary P0990474 Index Index P0990474Using to change IP address Index P0990474

P0990474 03 specifications

Nortel Networks P0990474 03 is a significant component in the realm of telecommunications, particularly in the area of networking solutions. This device is recognized for its robust engineering, which caters to a wide range of networking needs. As part of Nortel's extensive portfolio, it showcases the company's dedication to providing high-quality technology that meets the evolving demands of businesses.

One of the primary features of the P0990474 03 is its ability to support various networking topologies. This flexibility allows organizations to seamlessly integrate the device into their existing infrastructure, ensuring that they can effectively manage data flow and connectivity. The device is designed to enhance performance and reliability, which are critical factors in today's fast-paced digital environment.

In terms of technologies, the Nortel Networks P0990474 03 employs advanced switching capabilities that optimize bandwidth usage. By efficiently directing traffic within the network, it minimizes latency and maximizes performance, which is essential for applications that require real-time data access. Additionally, the device supports a variety of protocols, enabling interoperability with other networking equipment, which is vital for heterogeneous network environments.

One of the outstanding characteristics of the P0990474 03 is its scalability. Businesses can start with a basic setup and expand their systems as their needs grow. This scalability not only supports immediate requirements but also prepares organizations for future growth without necessitating a complete overhaul of their existing network architecture.

Furthermore, the P0990474 03 integrates security features designed to protect sensitive data from potential threats. With the increasing prevalence of cyber-attacks, having robust security measures is paramount for any organization. This device employs encryption, firewalls, and other security protocols to ensure that data remains protected while in transit.

Finally, the Nortel Networks P0990474 03 is recognized for its user-friendly interface, which simplifies the management and configuration processes for network administrators. With easier monitoring tools and reporting functionalities, managing extensive networks becomes less of a challenge, allowing IT teams to focus on strategic initiatives rather than day-to-day operational tasks.

In conclusion, the Nortel Networks P0990474 03 is a versatile, scalable, and secure networking device that stands out in the telecommunications landscape. Its ability to adapt to various network environments while delivering top-notch performance and reliability makes it an invaluable asset for businesses looking to enhance their networking capabilities.