Control Unit Menu Structure

The complete menu structure shown in the order in which it is accessed from the control unit display is presented in outline form below. Each indentation to the right represents a menu level below the indicated title.

T o p L e v e l

S e c o n d L e v e l

T h i r d L e v e l

F o u r t h L e v e l

 

 

 

 

 

 

MX28B200/400

+

Sys Voltage

 

 

 

STATUS ALARMS

 

 

 

 

 

Sys Current

 

 

 

 

Sys Temp

 

 

 

 

 

 

 

 

 

 

Batt Current

 

 

 

 

 

 

 

 

 

 

Batt Temp

 

 

 

MX28B200/400

+

Alarm Item 1

 

 

 

US ALARMS SYSTEM

 

 

 

 

Alarm Item 2

 

 

 

 

Alarm Item 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Item 14

 

 

 

 

 

 

 

 

Alarm Item 15

 

 

 

Alarm Item 16

 

 

 

 

 

 

 

 

MX28B200/400 +

 

SYS

+

 

 

MS SYSTEM MODULE

SET-ALM SETUP DA

Sys HV Thr

 

 

 

 

 

 

 

 

 

Sys HV Alm

 

 

 

Sys LV Thr

 

 

 

 

 

 

 

 

 

Sys LV Alm

 

 

 

Rect Cfg Alm

 

 

 

 

 

 

 

 

 

Rect 1ofN Alm

 

 

 

 

 

 

 

 

 

Rect 2ofN Alm

 

 

 

Sys HT Thr

 

 

 

 

 

 

 

 

 

Sys HT Alm

 

 

 

Sys LT Thr

 

 

 

 

 

 

 

 

 

Sys LT Alm

 

 

 

 

 

 

 

 

 

Hw Sys V Alm

 

 

 

Hw Batt C Alm

 

 

 

 

 

MX28B200/400 –48 VDC User’s Manual (990-9133)

Page 37

Image 43
Contents VDC Power Systems Page Table of Contents Remote Monitoring Revision Date Description Revision HistoryPage General Precautions Safety FirstPage General Information Introduction2 MX28B Block Diagram How to Use This Manual Page Room / Location InstallationMechanical Installation Unpacking EquipmentVentilation AC Power ConnectionsPlanning the Battery installation Battery ConnectionsConnecting the Cables DC System Grounding Battery Temperature Probe InstallationDC Circuit Breakers DC Power Output Over-Current Protection#10 studs on 5/8 centers Fuse Rating Part Number DC GMT FusesPlug-in Circuit Breaker Installation Installation of Circuit Breakers and FusesCircuit Breaker Connections 1 to 50 Amps GMT Fuse InstallationLoad Connections Cable Size Considerations1 Standard lug for 1 to 50A breakers Circuit Breaker Connections 60-100 Amps2 Adaptor and lugs for 60-100 Amp breakers GMT Fuse ConnectionsSmart Cable DB9 Connection RJ45 Ethernet ConnectorMonitoring and Relay Output Connections Front Panel DB9 ConnectionNO-NC-C External Alarm Input ConnectionsInitial Power-Up and Checkout Rectifier Module InstallationSystem Parameters Verification/Adjustment Full System Power Up Technical Description OperationRectifier Management System Current System ManagementSystem Output Capacity System Voltage ControlDC Distribution Battery ManagementSystem Status and Alarm Reporting Battery Charging and ProtectionFront Panel User Interface Controls and IndicatorsBattery Temperature Compensation Battery/Load Low Voltage DisconnectMX28B Status Alarms System Modules Batt PIN OEM Parameter Locations, Descriptions, and Default Values 10 a Batt Disc Alm m+Minor Batt Disc Thr m+Major Cir Bkr48V Cir Bkr 1 Alm m+GMT 8 Alm FW Version000189 GMT 1 AlmIgnore EnableLVD Reset In-Rly 1 AlmOut-Rly OEM S OffsetOut-Rly 1 Alm m+ Out-Rly 6 Alm m+Rect CL Alm RectFailCommMin Rect Cfg AlmRect RFA Alm DisableRect 1 FF Rect 1 RFA50.00 Sys LT ThrSys LV Alm Sys LV ThrControl Unit Menu Structure SYS MS System Module SET-ALM Setup DAV e l C o n d L e v e l I r d L e v e l U r t h L e v e l SYS Sysin AM Info Modgmt LM Alias GMT MOD Modlvd Front Panel LED Indicators External Alarm Inputs Input Relays Alarm Outputs Output RelaysPage Physical Connections Command and Monitoring ProtocolRemote Monitoring DescriptionPage 1MRF28H54BV50 Rectifiers SpecificationsAC Input 1MRF28H54BV RectifiersPscu RectifiersMechanical Power Shelf Control UnitMounting Compliance EnvironmentalPage APC Worldwide Customer Support Page General Provisions Warranty