American Power Conversion MX28B200 user manual Revision History, Revision Date Description

Page 5

Revision History

Revision

Date

By

Description

1

31 JAN, 2002

JNF

Converted to APC numbering

2

17 MAY, 2002

BET

Updated Format

 

 

 

 

 

 

 

 

Table of Figures

 

FIGURE 2.1-1 MX28B-400 –48 VDC POWER PLANT

3

FIGURE 2.1-2 MX28B BLOCK DIAGRAM

4

FIGURE 3.4-1 BATTERY CABLE CONNECTION LOCATIONS

10

FIGURE 3.6-1 DC DISTRIBUTION (FRONT COVER REMOVED)

11

FIGURE 3.7-1. INSTALLATION OF CIRCUIT BREAKERS

14

FIGURE 3.7-2 GMT FUS E TEMPERATURE DE-RATING CHART

15

FIGURE 3.8-1 STANDARD LUG FOR 1 TO 50A BREAKERS

16

FIGURE 3.8-2 ADAPTOR AND LUGS FOR 60-100 AMP BREAKERS

17

FIGURE 3.8-3 INTERFACE BOARD

17

FIGURE 4.6-1 MENU TOP LINE

27

MX28B200/400 –48 VDC User’s Manual (990-9133)

Page v

Image 5
Contents VDC Power Systems Page Table of Contents Remote Monitoring Revision Date Description Revision HistoryPage General Precautions Safety FirstPage General Information Introduction2 MX28B Block Diagram How to Use This Manual Page Mechanical Installation InstallationUnpacking Equipment Room / LocationVentilation AC Power ConnectionsConnecting the Cables Battery ConnectionsPlanning the Battery installation DC System Grounding Battery Temperature Probe InstallationDC Circuit Breakers DC Power Output Over-Current Protection#10 studs on 5/8 centers Fuse Rating Part Number DC GMT FusesPlug-in Circuit Breaker Installation Installation of Circuit Breakers and FusesLoad Connections GMT Fuse InstallationCable Size Considerations Circuit Breaker Connections 1 to 50 Amps1 Standard lug for 1 to 50A breakers Circuit Breaker Connections 60-100 Amps2 Adaptor and lugs for 60-100 Amp breakers GMT Fuse ConnectionsMonitoring and Relay Output Connections RJ45 Ethernet ConnectorFront Panel DB9 Connection Smart Cable DB9 ConnectionNO-NC-C External Alarm Input ConnectionsInitial Power-Up and Checkout Rectifier Module InstallationSystem Parameters Verification/Adjustment Full System Power Up Rectifier Management OperationTechnical Description System Output Capacity System ManagementSystem Voltage Control System CurrentSystem Status and Alarm Reporting Battery ManagementBattery Charging and Protection DC DistributionBattery Temperature Compensation Controls and IndicatorsBattery/Load Low Voltage Disconnect Front Panel User InterfaceMX28B Status Alarms System Modules Batt PIN OEM Parameter Locations, Descriptions, and Default Values Minor Batt Disc Alm m+Batt Disc Thr m+ 10 a48V Cir BkrCir Bkr 1 Alm m+ Major000189 FW VersionGMT 1 Alm GMT 8 AlmLVD Reset EnableIn-Rly 1 Alm IgnoreOut-Rly 1 Alm m+ OEM S OffsetOut-Rly 6 Alm m+ Out-RlyMin RectFailCommRect Cfg Alm Rect CL AlmRect 1 FF DisableRect 1 RFA Rect RFA AlmSys LV Alm Sys LT ThrSys LV Thr 50.00Control Unit Menu Structure SYS MS System Module SET-ALM Setup DAV e l C o n d L e v e l I r d L e v e l U r t h L e v e l SYS Sysin AM Info Modgmt LM Alias GMT MOD Modlvd Front Panel LED Indicators External Alarm Inputs Input Relays Alarm Outputs Output RelaysPage Remote Monitoring Command and Monitoring ProtocolDescription Physical ConnectionsPage AC Input Specifications1MRF28H54BV Rectifiers 1MRF28H54BV50 RectifiersPscu RectifiersMechanical Power Shelf Control UnitMounting Compliance EnvironmentalPage APC Worldwide Customer Support Page General Provisions Warranty