voltage (54.5 VDC).

 

 

Boost/Equalize Trim Pot

The boost/equalize pot is used to adjust the

 

default boost equalize voltage (57.5 VDC).

 

 

6.4. Controls and Indicators

Power Shelf Control Unit

Major (Red)

On when Major Relay is de-energized*

 

 

Minor (Yellow)

On when Minor Relay is energized

 

 

Normal (Green)

On when no alarms are active

 

 

ALM 1 (Red)

On when Output Relay 1 is energized

 

 

ALM 2 (Red)

On when Output Relay 2 is energized

 

 

ALM 3 (Red)

On when Output Relay 3 is energized

 

 

ALM 4 (Red)

On when Output Relay 4 is energized

 

 

ALM 5 (Red)

On when Output Relay 5 is energized

 

 

ALM 6 (Red)

On when Output Relay 6 is energized

 

 

MIN (Red)

On when Minor Relay is energized

 

 

MAJ (Red)

On when Major Relay is de-energized*

 

 

6.5. Mechanical

Dimensions

15.75” high x 23” wide x 17.5” deep (MX28B-200)

 

22.75” high x 23” wide x 17.5” deep (MX28B-400)

 

 

 

Weight

Housing

85 lbs. (MX28B-200)

 

 

110 lbs. (MX28B-400)

 

Rectifier (each)

11 lbs

 

 

 

Color

Dawn Gray

 

 

 

 

MX28B200/400 –48 VDC User’s Manual (990-9133)

Page 49

Image 55
Contents VDC Power Systems Page Table of Contents Remote Monitoring Revision Date Description Revision HistoryPage General Precautions Safety FirstPage General Information Introduction2 MX28B Block Diagram How to Use This Manual Page Room / Location InstallationMechanical Installation Unpacking EquipmentVentilation AC Power ConnectionsPlanning the Battery installation Battery ConnectionsConnecting the Cables DC System Grounding Battery Temperature Probe InstallationDC Circuit Breakers DC Power Output Over-Current Protection#10 studs on 5/8 centers Fuse Rating Part Number DC GMT FusesPlug-in Circuit Breaker Installation Installation of Circuit Breakers and FusesCircuit Breaker Connections 1 to 50 Amps GMT Fuse InstallationLoad Connections Cable Size Considerations1 Standard lug for 1 to 50A breakers Circuit Breaker Connections 60-100 Amps2 Adaptor and lugs for 60-100 Amp breakers GMT Fuse ConnectionsSmart Cable DB9 Connection RJ45 Ethernet ConnectorMonitoring and Relay Output Connections Front Panel DB9 ConnectionNO-NC-C External Alarm Input ConnectionsInitial Power-Up and Checkout Rectifier Module InstallationSystem Parameters Verification/Adjustment Full System Power Up Technical Description OperationRectifier Management System Current System ManagementSystem Output Capacity System Voltage ControlDC Distribution Battery ManagementSystem Status and Alarm Reporting Battery Charging and ProtectionFront Panel User Interface Controls and IndicatorsBattery Temperature Compensation Battery/Load Low Voltage DisconnectMX28B Status Alarms System Modules Batt PIN OEM Parameter Locations, Descriptions, and Default Values 10 a Batt Disc Alm m+Minor Batt Disc Thr m+Major Cir Bkr48V Cir Bkr 1 Alm m+GMT 8 Alm FW Version000189 GMT 1 AlmIgnore EnableLVD Reset In-Rly 1 AlmOut-Rly OEM S OffsetOut-Rly 1 Alm m+ Out-Rly 6 Alm m+Rect CL Alm RectFailCommMin Rect Cfg AlmRect RFA Alm DisableRect 1 FF Rect 1 RFA50.00 Sys LT ThrSys LV Alm Sys LV ThrControl Unit Menu Structure SYS MS System Module SET-ALM Setup DAV e l C o n d L e v e l I r d L e v e l U r t h L e v e l SYS Sysin AM Info Modgmt LM Alias GMT MOD Modlvd Front Panel LED Indicators External Alarm Inputs Input Relays Alarm Outputs Output RelaysPage Physical Connections Command and Monitoring ProtocolRemote Monitoring DescriptionPage 1MRF28H54BV50 Rectifiers SpecificationsAC Input 1MRF28H54BV RectifiersPscu RectifiersMechanical Power Shelf Control UnitMounting Compliance EnvironmentalPage APC Worldwide Customer Support Page General Provisions Warranty