E658130

5.5.4. Octuple setting is selected (CC-Link Ver.2) (c122=3)

This option occupies one station area of the buffer memory of the PLC.

In the case of c122 = 3, there are remote I/O (RX, RY both 32 bits(same as CC-LINK Ver.1)) and the remote register (RWw, RWr both 32 word) in the communication data for one station area.

* Default value of RY and RX is 0.

Remote register (Default value = 0)

RWr

Inverter → PLC

RWw

PLC → Inverter

Address

 

Signal

Address

 

Signal

RWr n

Monitor value 1

RWw n

Monitor code (1 and 2)

RWr n+1

Monitor value 2

RWw n+1

Set frequency

 

(output frequency)

 

 

 

 

 

 

 

 

 

RWr n+2

Reply code

 

RWw n+2

Instruction code

RWr n+3

Read data

 

RWw n+3

Write data

 

RWr n+4

Monitor value 3

RWw n+4

Monitor code 3

 

RWr n+

Monitor value 4

RWw n+5

Monitor code 4

 

RWr n+

Monitor value 5

RWw n+6

Monitor code 5

 

RWr n+

Monitor value 6

RWw n+7

Monitor code 6

 

 

Upper 8

Trip history No.

 

Upper 8

 

Trip history No..

 

Bits

 

Bits

 

RWr n+8

 

RWw n+8

 

 

Lower 8

Trip code

Lower 8

 

Reserved**

 

 

 

 

Bits

 

Bits

 

 

 

 

 

 

RWr n+9

Trip information (output frequency)

RWw n+9

Reserved**

 

RWr n+A

Trip information (output current)

RWw n+A

Reserved**

 

RWr n+B

Trip information (output voltage)

RWw n+B

Reserved**

 

RWr n+C

Trip information (energization time)

RWw n+C

Reserved**

 

RWr n+D

Reserved*

 

RWw n+D

Reserved**

 

RWr n+E

Reserved*

 

RWw n+E

Reserved**

 

RWr n+F

Reserved*

 

RWw n+F

Reserved**

 

RWr n+10

Reply code 2

 

RWw n+10

Instruction code 2

RWr n+11

Read data 2

 

RWw n+11

Write data 2

 

RWr n+12

Reply code 3

 

RWw n+12

Instruction code 3

RWr n+13

Read data 3

 

RWw n+13

Write data 3

 

RWr n+14

Reply code 4

 

RWw n+14

Instruction code 4

RWr n+1

Read data 4

 

RWw n+15

Write data 4

 

RWr n+1

Reply code 5

 

RWw n+16

Instruction code 5

RWr n+1

Read data 5

 

RWw n+17

Write data 5

 

RWr n+18

Reply code 6

 

RWw n+18

Instruction code 6

RWr n+19

Read data 6

 

RWw n+19

Write data 6

 

RWr n+1A

Reserved*

 

RWw n+1A

Reserved**

 

RWr n+1B

Reserved*

 

RWw n+1B

Reserved**

 

RWr n+1C

Reserved*

 

RWw n+1C

Reserved**

 

RWr n+1D

Reserved*

 

RWw n+1D

Reserved**

 

RWr n+1E

Reserved*

 

RWw n+1E

Reserved**

 

RWr n+1F

Reserved*

 

RWw n+1F

Reserved**

 

"n" is depend on the station number.

*The bit described " Reserved " is unstable. Don't use the “Reserved " bit for the judgment.

**Do not use it.

-19 -

Image 20
Contents CCL003Z Introduction Handling in general Table of Contents Basic specifications OverviewCC-Link Version CC-Link VerSLD Names and functionsOutline Terminating resistor Installation on inverterConnection cable Connection of CC-Link master unit and inverter DA,DBMaximum connection number of units Page RUN LED indicatorRUN ERR Initial setting FunctionsCommunication parameters for CCL003Z C101CC-Link function setting Station number setting Baud rate settingCC-Link extended setting Run and frequency operation command Basic functionsMonitor Writing and reading the parameterI/O signal list One station is occupied CC-Link Ver.1 c122=0 RAMDouble setting is selected CC-Link Ver.2 c122=1 Quadruple setting is selected CC-Link Ver.2 c122=2Octuple setting is selected CC-Link Ver.2 c122=3 Trip history Detail of input and output signals RYnF Instruction code execution request120 OFF ST = on On ST = OFFRemote Register Assignment Instruction code 3 It is the same as instruction code 1 Monitor code RWwn is set Signal Description Instruction Codes 00EDH00FCH 00FDHEx A900 A900H, C123 C123H Details of an error code Fault record display example Description of reply code Reply codeDescription of monitor code Description of input terminal information Description of output terminal informationProgramming examples SB0 SW0RWr0 END Program example for reading the inverter statusX0F Program example for setting the operation mode Program example for setting the operation commands Program example for setting the running frequencyPLS SETProgram example for monitoring the output frequency Program example for parameter writing Program example for parameter reading Program example for trip information reading MOVProgram example for resetting the inverter at inverter error Instructions Unusual diagnosis Option errorDisconnection error of network cable How to check the error using the LEDs CPUCCL003Z Time Line ERR RUNTime Line RUNTime RUN ERR Line RUNERR Time RUN Time ERR