Toshiba E6581830 instruction manual Ex A900 A900H, C123 C123H

Page 30

E658130

Code No.

Item

Description

 

 

To read parameters a900 to c999, 6000H is subtracted

4900H to 6999H

Read parameters (RAM)

from the parameter number.

(Ex: A900 A900H – 6000H = 4900H,

 

 

 

 

C123 -> C123H – 6000H = 6123H)

A900H to

Write parameters

To write parameters a900 to c999, the parameter

number doesn't change.

C999H

(EEPROM&RAM) *

(Ex: A900 -> A900H, C123 -> C123H)

 

 

 

 

 

*The Life of EEPROM is approximately 100,000 times. Avoid writing a command more than 100,000 times to

the same parameter of the drive and the option module.

- 29 -

Image 30
Contents CCL003Z Introduction Handling in general Table of Contents Basic specifications OverviewCC-Link Version CC-Link VerNames and functions OutlineSLD Installation on inverter Connection cableTerminating resistor Connection of CC-Link master unit and inverter DA,DBMaximum connection number of units Page LED indicator RUN ERRRUN Initial setting FunctionsCommunication parameters for CCL003Z C101CC-Link function setting Station number setting Baud rate settingCC-Link extended setting Monitor Run and frequency operation commandBasic functions Writing and reading the parameterI/O signal list One station is occupied CC-Link Ver.1 c122=0 RAMDouble setting is selected CC-Link Ver.2 c122=1 Quadruple setting is selected CC-Link Ver.2 c122=2Octuple setting is selected CC-Link Ver.2 c122=3 Trip history Detail of input and output signals RYnF Instruction code execution request120 OFF ST = on On ST = OFFRemote Register Assignment Instruction code 3 It is the same as instruction code 1 Monitor code RWwn is set Signal Description 00FCH Instruction Codes00EDH 00FDHEx A900 A900H, C123 C123H Details of an error code Fault record display example Description of reply code Reply codeDescription of monitor code Description of input terminal information Description of output terminal informationProgramming examples SB0 SW0RWr0 Program example for reading the inverter status X0FEND Program example for setting the operation mode PLS Program example for setting the operation commandsProgram example for setting the running frequency SETProgram example for monitoring the output frequency Program example for parameter writing Program example for parameter reading Program example for trip information reading MOVProgram example for resetting the inverter at inverter error Instructions Option error Disconnection error of network cableUnusual diagnosis How to check the error using the LEDs CPUTime CCL003ZTime Line ERR RUN Line RUNERR Time RUN Time RUNERR Line RUN Time ERR