Toshiba E6581830 instruction manual Table of Contents

Page 4

 

 

 

 

E658130

 

 

Table of Contents

 

1.

OVERVIEW

- 4 -

2.

BASIC SPECIFICATIONS

- 4 -

 

2.1.

CC-Link Version

- 5 -

 

2.1.1.

CC-Link Ver. 1.10

- 5 -

 

2.1.2.

CC-Link Ver. 2

- 5 -

3.

NAMES AND FUNCTIONS

- 6 -

 

3.1.

Outline

- 6 -

4.

INSTALLATION ON INVERTER

- 7 -

 

4.1.

Connection cable

- 7 -

 

4.2.

Terminating resistor

- 7 -

 

4.3. Connection of CC-Link master unit and inverter

- 8 -

 

4.4. The maximum connection number of units

- 9 -

 

4.5.

LED indicator

- 11 -

5.

FUNCTIONS

- 12 -

 

5.1.

Initial setting

- 12 -

 

5.2. Communication parameters for CCL003Z

- 13 -

 

5.3.

CC-Link function setting

- 14 -

 

5.3.1.

Station number setting

- 14 -

 

5.3.2.

Baud rate setting

- 14 -

 

5.3.3.

CC-Link extended setting

- 15 -

 

5.4.

Basic functions

- 16 -

 

5.4.1. Run and frequency operation command

- 16 -

 

5.4.2.

Monitor

- 16 -

 

5.4.3. Writing and reading the parameter

- 16 -

 

5.5.

I/O signal list

- 17 -

 

5.5.1. One station is occupied (CC-Link Ver.1) (c122=0)

- 17 -

 

5.5.2. Double setting is selected (CC-Link Ver.2) (c122=1)

- 18 -

 

5.5.3. Quadruple setting is selected (CC-Link Ver.2) (c122=2)

- 18 -

 

5.5.4. Octuple setting is selected (CC-Link Ver.2) (c122=3)

- 19 -

 

5.5.5.

Faults history

- 20 -

 

5.5.6. Detail of input and output signals

- 21 -

 

5.5.7.

Remote Register Assignment

- 24 -

 

5.5.8.

Instruction Codes

- 28 -

 

5.5.9. The details of an error code

- 30 -

 

5.5.10.

Description of reply code

- 32 -

 

5.5.11.

Description of monitor code

- 33 -

 

5.5.12.

Description of input terminal information

- 34 -

 

5.5.13.

Description of output terminal information

- 34 -

6.

PROGRAMMING EXAMPLES

- 35 -

 

6.1. Program example for reading the inverter status

- 38 -

 

6.2. Program example for setting the operation mode

- 39 -

 

6.3. Program example for setting the operation commands

- 40 -

 

6.4. Program example for setting the running frequency

- 40 -

 

6.5. Program example for monitoring the output frequency

- 41 -

 

6.6. Program example for parameter writing

- 42 -

 

6.7. Program example for parameter reading

- 43 -

 

6.8. Program example for fault record reading

- 44 -

 

6.9. Program example for resetting the inverter at inverter error

- 45 -

 

6.10.

Instructions

- 46 -

7.

UNUSUAL DIAGNOSIS

- 47 -

 

7.1.

Option error

- 47 -

 

7.2. Disconnection error of network cable

- 47 -

 

7.3. How to check the error using the LEDs

- 48 -

- 3 -

Image 4
Contents CCL003Z Introduction Handling in general Table of Contents Basic specifications OverviewCC-Link Version CC-Link VerOutline Names and functionsSLD Connection cable Installation on inverterTerminating resistor Connection of CC-Link master unit and inverter DA,DBMaximum connection number of units Page RUN ERR LED indicatorRUN Initial setting FunctionsCommunication parameters for CCL003Z C101CC-Link function setting Station number setting Baud rate settingCC-Link extended setting Run and frequency operation command Basic functionsMonitor Writing and reading the parameterI/O signal list One station is occupied CC-Link Ver.1 c122=0 RAMDouble setting is selected CC-Link Ver.2 c122=1 Quadruple setting is selected CC-Link Ver.2 c122=2Octuple setting is selected CC-Link Ver.2 c122=3 Trip history Detail of input and output signals RYnF Instruction code execution request120 OFF ST = on On ST = OFFRemote Register Assignment Instruction code 3 It is the same as instruction code 1 Monitor code RWwn is set Signal Description Instruction Codes 00EDH00FCH 00FDHEx A900 A900H, C123 C123H Details of an error code Fault record display example Description of reply code Reply codeDescription of monitor code Description of input terminal information Description of output terminal informationProgramming examples SB0 SW0RWr0 X0F Program example for reading the inverter statusEND Program example for setting the operation mode Program example for setting the operation commands Program example for setting the running frequencyPLS SETProgram example for monitoring the output frequency Program example for parameter writing Program example for parameter reading Program example for trip information reading MOVProgram example for resetting the inverter at inverter error Instructions Disconnection error of network cable Option errorUnusual diagnosis How to check the error using the LEDs CPUCCL003Z Time Line ERR RUNTime Line RUNTime RUN ERR Line RUNERR Time RUN Time ERR