Allied Telesis 9102 Safety Precautions While Working with Electricity, Electrostatic Discharge

Page 20

Allied Telesyn 9100 Installation Safety

Safety Precautions While Working with Electricity

The user should not perform any action that creates an unsafe or hazardous situation for themselves or other personnel.

1.7.2 Safety Precautions While Working with Electricity

Guidelines when working with electrically powered equipment:

Locate the Power Off switch for the system being installed or serviced. In the event of an electrical accident, the user can quickly turn the power off.

Disconnect all power by turning the circuit breakers off before:

Installing or removing a chassis

Working near the power supply

Do not work alone if potential hazards exist.

Never assume that power is disconnected from a circuit; always check the circuit.

Inspect the work area carefully for possible hazards, such as moist floors, moist or wet ground, ungrounded power extension cables, frayed power cords, and missing safety grounds.

If an electrical accident occurs, proceed as follows:

Use caution; do not become a victim yourself.

Turn off power to the system.

If possible, send another person to get medical aid. Otherwise, assess the condition of the victim and then call for help.

Determine if the person needs rescue breathing or external cardiac compressions; then, take appropriate action.

Ensure customer power source for the product is off.

Ensure that fuses A and B on the 9100 are removed.

1.7.3 Electrostatic Discharge

Electrostatic discharge (ESD) can damage equipment when electronic equipment is handled improperly. ESD damage can produce total or partial failures in electronic equipment. Follow these ESD-prevention procedures when handling systems cards and modules. Follow this procedure:

1.Verify that the frame is electrically connected to earth ground.

2.Wear an ESD-preventive device such as a foot strap or wrist strap, ensuring that it makes good contact with the user’s skin. If a foot strap is being used, the floor must be ESD conductive.

1-16Telesyn 9100 Installation Guide (Installation of Allied Telesyn 9100)

Image 20
Contents Page About this Guide Reason for UpdateWho Should Read This Guide? Table of Contents Appendix Installation Overview for Allied Telesyn 9100 ConfigurationFollowing Procedures for the 9101, 9102, Selecting a Site for1 9101 Site Requirements 2Site Requirements for Allied Telesyn2 9102/9103 Site Requirements 3Site Requirements for Allied Telesyn 91029102/9103 Site Requirements Selecting a Site for Setup Checklist 4Part Checklist for5Customer Item Checklist 1 9101 Parts Included in Order2 9102 / 9103 Parts Included in Order 6Part Checklist for7Part Checklist for 1 9101 Mounting Options 8Customer Item ChecklistShelf Mounting Options 4Front mount option for Shelf Mounting Options Center Mounting Option 2 9102/3 Mounting Options 6Front Mount for 9102/37Mid-Mount for 9102/3 Attaching the Extension Brackets and Rear Brackets Wall Mounting Option OverviewSafety Guidelines Allied Telesyn 9100 Installation SafetyInstalling the Wall Mount Safety Precautions While Working with Electricity Electrostatic DischargePrecautions and Conformance Standards Power and Grounding Cautions Installing Power and Ground forLaser Safety Instructions Connect Power and Ground Installing Power and Ground for Connect Power and Ground Connect the -48VDC office power supply to the 9101 PEM plug 129100 PEM plug with connections indicatedConnect to Power Source Single or Dual Apply and Check Power DC Power SupplyAlarm Connections 9101 Optional Apply and Check Power AC Power SupplyInstall Card Modules Install the CFC12Install the Service Module Install the SFP ModuleConfigure Local Terminal or PC Install Filler Plates FPF9Default Asynchronous Port Settings Option DefaultService Modules with RJ21connectors Connect System Cables13.4 GE4/FE2 SMs with RJ45 connectorsSMs with Optical connectors Data Management Cable Mgmt Port on CFC12 Apply Power and Check Startup Sequence Page Check management interfaces Check the configurationCheck software load Adding AC Power Module Allied Telesyn Contact InformationAppendix Glossary of TermsTelesyn 9100 Inventory Form 1Registration Information for the Telesyn