Allied Telesis 9103 Check the configuration, Check software load, Check management interfaces

Page 37

Check software load

Check the configuration

 

 

7.Check the management logs for any problems by typing the following:

>SHOW LOG SEVERITY=CRITICAL

>SHOW LOG SEVERITY=MAJOR

>SHOW LOG SEVERITY=MINOR

8.Check for any alarm conditions by inputting the following:

>SHOW ALARMS ALL

9.Determine if there are any faults as a result of performing Steps 6 and 7.

If any logs are produced, or if an alarm has a status other than INFO, contact your Allied Telesyn representa- tive and review the output.

Note: If the MAC device is bad, the following is produced:

-A SYS009 log is generated with text “Can Not Read MAC Address”

-A major alarm is set against the shelf with the text “Can Not Read MAC Address”

If there are no faults, go to 1.15.

If there are faults, contact Allied Telesyn Technical Support.

1.15 Check the configuration

1.15.1 Check software load

Although control modules and service modules are shipped with release files already present in FLASH memory, the release file should be compared with the latest software release files that are available from Allied Telesyn or if this is a replacement card, the current system loads. See section 1.17 for contact information.

Once a software release file is downloaded onto a network server, copy it to the Control Module FLASH file sys- tem, load it into FLASH memory, make it the active load, and ensure that when the Control Module reboots this latest load is always used. If this is a replacement card, make sure that the current system load is loaded into the card. Also ensure the service module loads are obtained from the control module.

Details on the steps to do this are in section, File Management and Software Release Upgrade of the Allied Telesyn User Guide.

Refer to the Allied Telesyn Component Specification for information on 9100 hardware and software compati- bilities.

1.15.2 Check management interfaces

The Allied Telesyn 9100 is now connected to a local terminal over an RJ-45 cable and can be queried. Refer to the Allied Telesyn User Guide, Section 2.4, which shows how to query the initial Allied Telesyn 9100 status.

Chapter 3 of the Allied Telesyn User Guide can then be used to configure the management interfaces.

Telesyn 9100 Installation Guide (Installation of Allied Telesyn 9100)

1-33

Image 37
Contents Page Who Should Read This Guide? Reason for UpdateAbout this Guide Table of Contents Appendix Allied Telesyn 9100 Configuration Installation Overview forSelecting a Site for Following Procedures for the 9101, 9102,2Site Requirements for Allied Telesyn 1 9101 Site Requirements3Site Requirements for Allied Telesyn 9102 2 9102/9103 Site Requirements9102/9103 Site Requirements Selecting a Site for 4Part Checklist for Setup Checklist5Customer Item Checklist 1 9101 Parts Included in Order7Part Checklist for 6Part Checklist for2 9102 / 9103 Parts Included in Order Shelf Mounting Options 8Customer Item Checklist1 9101 Mounting Options 4Front mount option for Shelf Mounting Options Center Mounting Option 6Front Mount for 9102/3 2 9102/3 Mounting Options7Mid-Mount for 9102/3 Attaching the Extension Brackets and Rear Brackets Overview Wall Mounting OptionInstalling the Wall Mount Allied Telesyn 9100 Installation SafetySafety Guidelines Electrostatic Discharge Safety Precautions While Working with ElectricityPrecautions and Conformance Standards Laser Safety Instructions Installing Power and Ground forPower and Grounding Cautions Connect Power and Ground Installing Power and Ground for Connect Power and Ground 129100 PEM plug with connections indicated Connect the -48VDC office power supply to the 9101 PEM plugApply and Check Power DC Power Supply Connect to Power Source Single or DualApply and Check Power AC Power Supply Alarm Connections 9101 OptionalInstall the CFC12 Install Card ModulesInstall the SFP Module Install the Service ModuleInstall Filler Plates FPF Configure Local Terminal or PCOption Default 9Default Asynchronous Port SettingsConnect System Cables Service Modules with RJ21connectorsSMs with Optical connectors SMs with RJ45 connectors13.4 GE4/FE2 Data Management Cable Mgmt Port on CFC12 Apply Power and Check Startup Sequence Page Check software load Check the configurationCheck management interfaces Allied Telesyn Contact Information Adding AC Power ModuleGlossary of Terms Appendix1Registration Information for the Telesyn Telesyn 9100 Inventory Form