Panasonic WJ-RT416 manual Shutdown of the recorder, To shut down the recorder, do the following

Page 18

Shutdown of the recorder

To shut down the recorder, do the following.

z

x

When the manual recording is currently being performed, stop recording.

Hold down the [REC] button for 2 seconds or more. The lit camera selection button indicating the current recording camera channel will go off and all recordings will stop.

Refer to page 21 for how to stop the timer recording or the alarm recording.

When playing recorded images, stop playback.

• Press the [STOP] button.

Press the power button on the rear panel after confirming that all the HDD access indicators are off.

• When the power supply is cut, the OPERATE indicator will go off.

Important:

Unplug when unused for long period of time.

When the recorder has not been used for a certain period, turn on the power of the recorder (approximately once a week) to prevent interferences with functions.

18

Image 18
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Class 1 Laser Product Important Notice for U.S. fileds onlyDisclaimer of warranty Limitation of liabilityImportant safety instructions Contents Precautions Indication label CleaningProduct disposal/transfer MPEG-4 Visual patent portfolio licenseFeatures PrefaceVarious Recording Functions About these operating instructions Trademarks and registered trademarksMajor operating controls and their functions Front View6Stop button Stop 4Escape button ESC5Set button SET 7Play/Pause button PLAY/PAUSERear View 7Power cord inlet AC Connect the provided power cord to this inletImage display When displaying images on a 16-split screenExample When displaying images from camera channel 040000PMStartup Start up the recorder as followsAdjustment of the clock of the recorder Display the setup menu by pressing the Setup buttonSystem Setup window will be displayed To shut down the recorder, do the following When playing recorded images, stop playbackShutdown of the recorder Press the Stop buttonDisplay images on a single screen Available functions when displaying live imagesMonitor live images from the cameras Display images from cameras on a multi-screenSequential display on a single screen Sequential display on a 4-split screenRecording Timer recordingAlarm recording Manual recordingAvailable functions when playing images PlaybackFast forward playback/Fast reverse playback Frame by frame forward playback PausingSkip playback Frame by frame reverse playbackSearch and play Camera NoStart Start/End Search and play with multiple search filtersSearched FilteringSearch result window will be displayed Alarm function Action at an event occurrence alarm actionCancel the alarm action Records alarm logsStarts recording automatically Alarm recording Copying Duplicate Display the Copy window by pressing the Copy buttonCopy List window will be displayed Log in as a different user Log outUser Management window will be displayed Log Operation restriction differences between the user levelsCheck HDD information Maintenance window will be displayedDisk management Disk Management window will be displayedCapacity UsedHour Meter Format all the HDDs Format the HDDFormat only the selected HDD Display the Disk Management windowDisk Management window will be displayed again Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Since the replace HDD is unformatted yet, format the HDDRestore HDD management information Operate the recorder using a PC Functions and their descriptionsSystem requirements for a PC Installation InstallationHDD safety mode When completing the installation, press the SET buttonHDD replacement HDD additionRack mounting Connection Basic connectionConnection with RS485 cameras RS485 cable WV-CA48/50When connecting a single unit with a controller Connection with PS·Data systemsDIP switches Connection with a PC Connect the recorder and a PC directlyAdd the recorder to the existing network Operation Accessible number Add the recorder to a broadband WAN Wide Area NetworkOFF Audio IN/ALARM OUT terminal Pin No Signal Operation RemarkRS485 Camera port Alarm IN/CONTROL terminal Setup menu Setup menu chartBasic operation of the setup menu Configure the system settings System Setup Default Off Summer Time DST Table Auto Adjust TimeDefault Off Summer Time DST Default Search TimeConfigure the recording settings Recording Setup Configure the common recording settings Common SetupDefault Field Advanced SetupDefault 4 Sec Resolution Time Per FileConfigure the manual recording settings Manual Rec. Setup Configure the timer recording settings Timer Rec. SetupDefault On Alarm Spot Configure the alarm action settings Event SetupAlarm Buzz Default OnConfigure the alarm recording settings Alarm Rec. Setup Alarm Output Port VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Spot Camera NoCamera Allocation Setup Configure the display settings Display SetupDefault All Status DisplayType ProtocolCompensation Configure the network settings Network Setup Configure the RS485 settings RS485 Setup Configure the PS·Data settings PS.Data SetupAlarm Data Default None Stop BitDefault 1 bit Retry Timing Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Set the password Password Refer to page 31 for how to log out of the recorderLogout of the recorder Logout Maintenance functions Maintenance Check the alarm log Alarm LogCheck the Error Log Error Log Manage the HDDs Disk Management Current Temperature Highest TemperatureCheck the system information System Information Following can be checkedFollowing information will be displayed for Type Reset the current settings to the default Factory DefaultReboot the recorder Reboot System MonitorAccess Log User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Check the detailed information Advanced InformationFirmware Update Operation using the system controller OperationWJ-RT416 WV-CU650Stop playback Available only when the search window isPlay Fast forward/slow playbackTroubleshooting Symptom13, 49 58-60 Symptom Input/Output SpecificationsGeneral FunctionStandard accessories Recording time lengthPanasonic Canada Inc Panasonic System Solutions CompanyFor business users in the European Union Panasonic Sales Company
Related manuals
Manual 59 pages 63.52 Kb