Panasonic WJ-RT416V manual Default None Stop Bit, Select a stop bit from the following bit/2 bit

Page 65

Baud Rate

Select the communication speed for data transmission with a connected device from the following.

2 400/4 800/9 600/19 200/38 400 bps Default: 9 600

Data Bit

The data bit will be displayed. It is impossible to change the value for this setting.

8(bit)

Parity

Select a method to check a transmission error at com- munication from the following.

None: No parity check

Even: Even parity

Odd: Odd parity

Default: None

Stop Bit

Select a stop bit from the following. 1 bit/2 bit

Default: 1 (bit)

Retry Timing

Select a retransmission interval for when data reception is not confirmed from the following.

Off/100 ms/200 ms/400 ms/1 000 ms Default: Off

Alarm Data

Select a method to inform the connected controller of an event occurrence from the following.

Off: Does not function.

0s: Informs the controller every time an event is detect- ed.

1s/5s: Informs the controller when a specified time has passed after detecting an event.

Default: 1 s

Camera Number Setup

It is possible to assign a number to each camera chan- nel to operate cameras using the controller compatible with PS·Data.

Do the following to assign numbers to the camera chan- nels.

(1)Move the cursor onto "Set" next to "Channel No." and press the [SET] button.

The "Channel No." menu will be displayed.

 

 

Camera Number Setup

 

 

 

Port

Cam

Port

Cam

 

 

 

 

 

 

 

 

 

 

 

1

 

001

 

2

 

002

 

 

 

 

 

 

 

 

 

 

 

3

 

003

 

4

 

004

 

 

 

 

 

 

 

 

 

 

 

5

 

005

 

6

 

006

 

 

 

 

 

 

 

 

 

 

 

7

 

007

 

8

 

008

 

 

 

 

 

 

 

 

 

 

 

9

 

009

 

10

 

010

 

 

 

 

 

 

 

 

 

 

 

11

 

011

 

12

 

012

 

 

 

 

 

 

 

 

 

 

 

13

 

013

 

14

 

014

 

 

 

 

 

 

 

 

 

 

 

15

 

015

 

16

 

016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

Cancel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2)Assign a camera number (to be operated using the controller) for each camera port using the camera selection buttons.

(3)After completing the camera number assignment, move the cursor onto [OK] and press the [SET] but- ton.

65

Image 65
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Important Notice for U.S. fileds only Class 1 Laser ProductLimitation of liability Disclaimer of warrantyImportant safety instructions Contents Precautions Product disposal/transfer CleaningIndication label MPEG-4 Visual patent portfolio licenseVarious Recording Functions FeaturesPreface Trademarks and registered trademarks About these operating instructionsFront View Major operating controls and their functions5Set button SET 4Escape button ESC6Stop button Stop 7Play/Pause button PLAY/PAUSERear View Connect the provided power cord to this inlet 7Power cord inlet ACExample When displaying images from camera channel When displaying images on a 16-split screenImage display 040000PMStart up the recorder as follows StartupSystem Setup window will be displayed Adjustment of the clock of the recorderDisplay the setup menu by pressing the Setup button Shutdown of the recorder When playing recorded images, stop playbackTo shut down the recorder, do the following Press the Stop buttonMonitor live images from the cameras Available functions when displaying live imagesDisplay images on a single screen Display images from cameras on a multi-screenSequential display on a 4-split screen Sequential display on a single screenAlarm recording Timer recordingRecording Manual recordingFast forward playback/Fast reverse playback Available functions when playing imagesPlayback Skip playback PausingFrame by frame forward playback Frame by frame reverse playbackStart Search and playCamera No Searched Search and play with multiple search filtersStart/End FilteringSearch result window will be displayed Action at an event occurrence alarm action Alarm functionStarts recording automatically Alarm recording Cancel the alarm actionRecords alarm logs Display the Copy window by pressing the Copy button Copying DuplicateCopy List window will be displayed User Management window will be displayed Log in as a different userLog out Operation restriction differences between the user levels LogDisk management Maintenance window will be displayedCheck HDD information Disk Management window will be displayedHour Meter CapacityUsed Format only the selected HDD Format the HDDFormat all the HDDs Display the Disk Management windowWhen completing the HDD replacement, press the SET button Stop power supply to the HDDDisk Management window will be displayed again Since the replace HDD is unformatted yet, format the HDDRestore HDD management information System requirements for a PC Operate the recorder using a PCFunctions and their descriptions HDD safety mode InstallationInstallation When completing the installation, press the SET buttonHDD addition HDD replacementRack mounting Basic connection ConnectionRS485 cable WV-CA48/50 Connection with RS485 camerasConnection with PS·Data systems When connecting a single unit with a controllerDIP switches Add the recorder to the existing network Connection with a PCConnect the recorder and a PC directly Add the recorder to a broadband WAN Wide Area Network Operation Accessible numberOFF RS485 Camera port Audio IN/ALARM OUT terminalPin No Signal Operation Remark Alarm IN/CONTROL terminal Setup menu chart Setup menuBasic operation of the setup menu Configure the system settings System Setup Default Off Summer Time DST Auto Adjust TimeDefault Off Summer Time DST Table Default Search TimeConfigure the common recording settings Common Setup Configure the recording settings Recording SetupDefault 4 Sec Resolution Advanced SetupDefault Field Time Per FileConfigure the timer recording settings Timer Rec. Setup Configure the manual recording settings Manual Rec. SetupAlarm Buzz Configure the alarm action settings Event SetupDefault On Alarm Spot Default OnConfigure the alarm recording settings Alarm Rec. Setup Default 030 sec Alarm Duration VMD Area Setup Set the VMD areaAlarm Output Port Alarm Spot Camera NoDefault All Configure the display settings Display SetupCamera Allocation Setup Status DisplayCompensation TypeProtocol Configure the network settings Network Setup Configure the PS·Data settings PS.Data Setup Configure the RS485 settings RS485 SetupDefault 1 bit Retry Timing Default None Stop BitAlarm Data Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Logout of the recorder Logout Set the password PasswordRefer to page 31 for how to log out of the recorder Check the Error Log Error Log Maintenance functions MaintenanceCheck the alarm log Alarm Log Check the system information System Information Current Temperature Highest TemperatureManage the HDDs Disk Management Following can be checkedReboot the recorder Reboot System Reset the current settings to the default Factory DefaultFollowing information will be displayed for Type MonitorTC YYYY-MM-DD Hhmmss Restore Default Settings User number 1 20, a Auto Login UserAccess Log Check the detailed information Advanced InformationFirmware Update OperationWJ-RT416 WV-CU650 Operation using the system controllerPlay Available only when the search window isStop playback Fast forward/slow playbackSymptom Troubleshooting13, 49 58-60 Symptom General SpecificationsInput/Output FunctionRecording time length Standard accessoriesFor business users in the European Union Panasonic System Solutions CompanyPanasonic Canada Inc Panasonic Sales Company