Panasonic WJ-RT416V manual Add the recorder to a broadband WAN Wide Area Network

Page 47

Add the recorder to a broadband WAN (Wide Area Network)

Broadband router A (WAN WJ-RT416)

TCP/UDP port: 2000 (configured on the WJ-RT416)

HDD

SEQUENCE

 

 

 

SEARCH

STOP

PLAY

PAUSE

REC

1

 

1

2

3

4

 

 

 

 

ERROR

 

 

 

 

SETUP

COPY

 

 

 

2

 

 

 

 

 

 

 

 

 

ALARM

MULTI

5

6

7

8

REV

FWD

 

SKIP

3

SCREEN

 

 

 

 

 

 

 

 

TIMER

 

 

 

 

 

 

 

+

4

 

9

10/0

11

12

 

 

 

 

 

 

 

 

 

 

5

ALARM

 

 

 

ESC

 

 

 

 

OPERATE

RESET

 

 

 

 

SET

 

 

 

6

 

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Disk Recorder WJ-RT416

Server port: 2000 (editable)

WAN

Broadband router B (WAN PC)

UDP port: 999 (fixed)

PC

Important:

When the recorder is in a WAN, maximum accessible number will become as follows.

Operation

 

Accessible number*

 

 

Monitoring of live images

Total of 16 areas

 

 

Playback of recorded images

Total of 4 areas

 

 

 

Frame display

4

PCs (4 users)

 

 

 

Download of recorded images

4

PCs (4 users)

 

 

 

Audio transmission/reception

1

PC (1 user)

 

 

 

*"Accessible number" is the number of the camera channels that can be displayed in the display area of the monitoring software.

It is necessary to log in first to play/download recorded images and transmit/receive audio.

If live images are transmitted using Multicast, the chart above is not applicable.

Only “Manager1” is capable of voice call. (page 67)

When displaying images from 5 or more camera channels, or when displaying recorded images in an area on a multi-screen, only I-frame* will be displayed in all areas on a multi-screen and audio may not be heard.

*: Short for intra frame. I-frame is an image that is to be inserted in the intra refresh period of MPEG images.

DIP Switch Setting

When the unit is used together with the PS·Data devices, use the RS485 cable provided with the system controller.

In this case, it is necessary to terminate both devices on both ends of the connection if they are connected with the RS485 cable.

Termination of this unit can be set with the DIP termination switch on the rear panel, and the setting of the mode selection DIP switch varies whether to use this unit as a receiver or a system controller.

When connecting to the system controller and this unit is connected as the end of the PS·Data connection, set mode selection DIP switch 2 to "ON".

When connecting to the system device and this unit is connected as the end of the PS·Data connection, set mode selection DIP switch 1 to "ON".

47

Image 47
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Important Notice for U.S. fileds only Class 1 Laser ProductLimitation of liability Disclaimer of warrantyImportant safety instructions Contents Precautions MPEG-4 Visual patent portfolio license CleaningProduct disposal/transfer Indication labelVarious Recording Functions FeaturesPreface Trademarks and registered trademarks About these operating instructionsFront View Major operating controls and their functions7Play/Pause button PLAY/PAUSE 4Escape button ESC5Set button SET 6Stop button StopRear View Connect the provided power cord to this inlet 7Power cord inlet AC040000PM When displaying images on a 16-split screenExample When displaying images from camera channel Image displayStart up the recorder as follows StartupSystem Setup window will be displayed Adjustment of the clock of the recorderDisplay the setup menu by pressing the Setup button Press the Stop button When playing recorded images, stop playbackShutdown of the recorder To shut down the recorder, do the followingDisplay images from cameras on a multi-screen Available functions when displaying live imagesMonitor live images from the cameras Display images on a single screenSequential display on a 4-split screen Sequential display on a single screenManual recording Timer recordingAlarm recording RecordingFast forward playback/Fast reverse playback Available functions when playing imagesPlayback Frame by frame reverse playback PausingSkip playback Frame by frame forward playbackStart Search and playCamera No Filtering Search and play with multiple search filtersSearched Start/EndSearch result window will be displayed Action at an event occurrence alarm action Alarm functionStarts recording automatically Alarm recording Cancel the alarm actionRecords alarm logs Display the Copy window by pressing the Copy button Copying DuplicateCopy List window will be displayed User Management window will be displayed Log in as a different userLog out Operation restriction differences between the user levels LogDisk Management window will be displayed Maintenance window will be displayedDisk management Check HDD informationHour Meter CapacityUsed Display the Disk Management window Format the HDDFormat only the selected HDD Format all the HDDsSince the replace HDD is unformatted yet, format the HDD Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Disk Management window will be displayed againRestore HDD management information System requirements for a PC Operate the recorder using a PCFunctions and their descriptions When completing the installation, press the SET button InstallationHDD safety mode InstallationHDD addition HDD replacementRack mounting Basic connection ConnectionRS485 cable WV-CA48/50 Connection with RS485 camerasConnection with PS·Data systems When connecting a single unit with a controllerDIP switches Add the recorder to the existing network Connection with a PCConnect the recorder and a PC directly Add the recorder to a broadband WAN Wide Area Network Operation Accessible numberOFF RS485 Camera port Audio IN/ALARM OUT terminalPin No Signal Operation Remark Alarm IN/CONTROL terminal Setup menu chart Setup menuBasic operation of the setup menu Configure the system settings System Setup Default Search Time Auto Adjust TimeDefault Off Summer Time DST Default Off Summer Time DST TableConfigure the common recording settings Common Setup Configure the recording settings Recording SetupTime Per File Advanced SetupDefault 4 Sec Resolution Default FieldConfigure the timer recording settings Timer Rec. Setup Configure the manual recording settings Manual Rec. SetupDefault On Configure the alarm action settings Event SetupAlarm Buzz Default On Alarm SpotConfigure the alarm recording settings Alarm Rec. Setup Alarm Spot Camera No VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Output PortStatus Display Configure the display settings Display SetupDefault All Camera Allocation SetupCompensation TypeProtocol Configure the network settings Network Setup Configure the PS·Data settings PS.Data Setup Configure the RS485 settings RS485 SetupDefault 1 s Camera Number Setup Default None Stop BitDefault 1 bit Retry Timing Alarm DataRestrict the operable functions User Level Setup Logout of the recorder Logout Set the password PasswordRefer to page 31 for how to log out of the recorder Check the Error Log Error Log Maintenance functions MaintenanceCheck the alarm log Alarm Log Following can be checked Current Temperature Highest TemperatureCheck the system information System Information Manage the HDDs Disk ManagementMonitor Reset the current settings to the default Factory DefaultReboot the recorder Reboot System Following information will be displayed for TypeCheck the detailed information Advanced Information User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Access LogFirmware Update OperationWJ-RT416 WV-CU650 Operation using the system controllerFast forward/slow playback Available only when the search window isPlay Stop playbackSymptom Troubleshooting13, 49 58-60 Symptom Function SpecificationsGeneral Input/OutputRecording time length Standard accessoriesPanasonic Sales Company Panasonic System Solutions CompanyFor business users in the European Union Panasonic Canada Inc
Related manuals
Manual 59 pages 63.52 Kb