Panasonic WJ-RT416V manual Configure the network settings Network Setup

Page 63

Configure the settings relating to communications with other devices [Communication Setup]

It is necessary to conform the setting such as the communication protocol and the line speed when connecting an external device such as a system controller to the DATA port or the RS485 port.

It is also necessary to configure the network settings such as the IP address and the gateway address to operate the recorder using a PC via a network.

The following is the required setting to communicate with external devices.

Communication Setup

Network Setup

RS485 Setup

PS.Data Setup

q

w

e

q Configure the network settings [Network Setup]

To operate the recorder using a PC via a network, configure the basic network settings.

Network Setup

DHCP

IP Address

Subnet Mask

Gateway

Line Speed

Advanced Setup

Off

192.168.000.250

255.255.255.000

192.168.000.001

Auto

Set

OK

Cancel

DHCP

Select "On" or "Off" to determine whether or not to use the DHCP server.

Select "On" when obtaining values for "IP Address", "Subnet Mask" and "Gateway" from the DHCP server.

Select "Off" when entering values for "IP Address", "Subnet Mask" and "Gateway" manually.

On: Use the DHCP server

Off: Not use the DHCP server

Default: off

IP Address

Enter an IP address. For this recorder, enter 4 units from the decimal numbers (0-255).

Default: 192.168.0.250

Subnet Mask

Enter a subnet mask according to the network configura- tion.

Default: 255.255.255.000

Gateway

Enter a gateway address according to the network configu- ration.

Default: 192.168.0.1

Line Speed

The following is available for the line speed. Auto: Line speed will be applied automatically. 100M-Half:100 Mbps half duplex 10M-Half:10 Mbps half duplex

100M-Full:100 Mbps full duplex

10M-Full:10 Mbps full duplex

Default: Auto

63

Image 63
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Important Notice for U.S. fileds only Class 1 Laser ProductLimitation of liability Disclaimer of warrantyImportant safety instructions Contents Precautions MPEG-4 Visual patent portfolio license CleaningProduct disposal/transfer Indication labelFeatures PrefaceVarious Recording Functions Trademarks and registered trademarks About these operating instructionsFront View Major operating controls and their functions7Play/Pause button PLAY/PAUSE 4Escape button ESC5Set button SET 6Stop button StopRear View Connect the provided power cord to this inlet 7Power cord inlet AC040000PM When displaying images on a 16-split screenExample When displaying images from camera channel Image displayStart up the recorder as follows StartupAdjustment of the clock of the recorder Display the setup menu by pressing the Setup buttonSystem Setup window will be displayed Press the Stop button When playing recorded images, stop playbackShutdown of the recorder To shut down the recorder, do the followingDisplay images from cameras on a multi-screen Available functions when displaying live imagesMonitor live images from the cameras Display images on a single screenSequential display on a 4-split screen Sequential display on a single screenManual recording Timer recordingAlarm recording RecordingAvailable functions when playing images PlaybackFast forward playback/Fast reverse playback Frame by frame reverse playback PausingSkip playback Frame by frame forward playbackSearch and play Camera NoStart Filtering Search and play with multiple search filtersSearched Start/EndSearch result window will be displayed Action at an event occurrence alarm action Alarm functionCancel the alarm action Records alarm logsStarts recording automatically Alarm recording Display the Copy window by pressing the Copy button Copying DuplicateCopy List window will be displayed Log in as a different user Log outUser Management window will be displayed Operation restriction differences between the user levels LogDisk Management window will be displayed Maintenance window will be displayedDisk management Check HDD informationCapacity UsedHour Meter Display the Disk Management window Format the HDDFormat only the selected HDD Format all the HDDsSince the replace HDD is unformatted yet, format the HDD Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Disk Management window will be displayed againRestore HDD management information Operate the recorder using a PC Functions and their descriptionsSystem requirements for a PC When completing the installation, press the SET button InstallationHDD safety mode InstallationHDD addition HDD replacementRack mounting Basic connection ConnectionRS485 cable WV-CA48/50 Connection with RS485 camerasConnection with PS·Data systems When connecting a single unit with a controllerDIP switches Connection with a PC Connect the recorder and a PC directlyAdd the recorder to the existing network Add the recorder to a broadband WAN Wide Area Network Operation Accessible numberOFF Audio IN/ALARM OUT terminal Pin No Signal Operation RemarkRS485 Camera port Alarm IN/CONTROL terminal Setup menu chart Setup menuBasic operation of the setup menu Configure the system settings System Setup Default Search Time Auto Adjust TimeDefault Off Summer Time DST Default Off Summer Time DST TableConfigure the common recording settings Common Setup Configure the recording settings Recording SetupTime Per File Advanced SetupDefault 4 Sec Resolution Default FieldConfigure the timer recording settings Timer Rec. Setup Configure the manual recording settings Manual Rec. SetupDefault On Configure the alarm action settings Event SetupAlarm Buzz Default On Alarm SpotConfigure the alarm recording settings Alarm Rec. Setup Alarm Spot Camera No VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Output PortStatus Display Configure the display settings Display SetupDefault All Camera Allocation SetupType ProtocolCompensation Configure the network settings Network Setup Configure the PS·Data settings PS.Data Setup Configure the RS485 settings RS485 SetupDefault 1 s Camera Number Setup Default None Stop BitDefault 1 bit Retry Timing Alarm DataRestrict the operable functions User Level Setup Set the password Password Refer to page 31 for how to log out of the recorderLogout of the recorder Logout Maintenance functions Maintenance Check the alarm log Alarm LogCheck the Error Log Error Log Following can be checked Current Temperature Highest TemperatureCheck the system information System Information Manage the HDDs Disk ManagementMonitor Reset the current settings to the default Factory DefaultReboot the recorder Reboot System Following information will be displayed for TypeCheck the detailed information Advanced Information User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Access LogFirmware Update OperationWJ-RT416 WV-CU650 Operation using the system controllerFast forward/slow playback Available only when the search window isPlay Stop playbackSymptom Troubleshooting13, 49 58-60 Symptom Function SpecificationsGeneral Input/OutputRecording time length Standard accessoriesPanasonic Sales Company Panasonic System Solutions CompanyFor business users in the European Union Panasonic Canada Inc