Configure the settings relating to communications with other devices [Communication Setup]
It is necessary to conform the setting such as the communication protocol and the line speed when connecting an external device such as a system controller to the DATA port or the RS485 port.
It is also necessary to configure the network settings such as the IP address and the gateway address to operate the recorder using a PC via a network.
The following is the required setting to communicate with external devices.
Communication Setup
Network Setup
RS485 Setup
PS.Data Setup
q
w
e
q Configure the network settings [Network Setup]
To operate the recorder using a PC via a network, configure the basic network settings.
Network Setup
DHCP
IP Address
Subnet Mask
Gateway
Line Speed
Advanced Setup
Off
192.168.000.250
255.255.255.000
192.168.000.001
Auto
Set→
OK
Cancel
■DHCP
Select "On" or "Off" to determine whether or not to use the DHCP server.
Select "On" when obtaining values for "IP Address", "Subnet Mask" and "Gateway" from the DHCP server.
Select "Off" when entering values for "IP Address", "Subnet Mask" and "Gateway" manually.
On: Use the DHCP server
Off: Not use the DHCP server
Default: off
■IP Address
Enter an IP address. For this recorder, enter 4 units from the decimal numbers
Default: 192.168.0.250
■Subnet Mask
Enter a subnet mask according to the network configura- tion.
Default: 255.255.255.000
■Gateway
Enter a gateway address according to the network configu- ration.
Default: 192.168.0.1
■Line Speed
The following is available for the line speed. Auto: Line speed will be applied automatically.
Default: Auto
63