Panasonic WJ-RT416V manual RS485 Camera port, Audio IN/ALARM OUT terminal

Page 49

RS485 (CAMERA) port

When connecting an RS485 camera, connect it to the RS485 (CAMERA) port on the rear of the recorder.

RS485(CAMERA)

Signal TA TB

RA RB Signal

GND

 

 

 

 

GND

OUT

 

IN

Block diagram

RA

RB

TA

TB

AUDIO IN/ALARM OUT terminal

!3 q

Control circuit

AUDIO IN/ALARM OUT

@5 !4

Normally close output

Common output

Normally open output

Internal block diagram

In normal

At an alarm

state

occurrence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin No.

Signal

Operation

Remark

q

Audio input CH7

Audio input (CH7)

–10 dBv 51 k, unbalanced

 

 

 

 

w

Audio input CH8

Audio input (CH8)

–10 dBv 51 k, unbalanced

 

 

 

 

e

Audio input CH9

Audio input (CH9)

–10 dBv 51 k, unbalanced

 

 

 

 

r

Audio input CH10

Audio input (CH10)

–10 dBv 51 k, unbalanced

 

 

 

 

t

Audio input CH11

Audio input (CH11)

–10 dBv 51 k, unbalanced

 

 

 

 

y

Audio input CH12

Audio input (CH12)

–10 dBv 51 k, unbalanced

 

 

 

 

u

Audio input CH13

Audio input (CH13)

–10 dBv 51 k, unbalanced

 

 

 

 

i

Audio input CH14

Audio input (CH14)

–10 dBv 51 k, unbalanced

 

 

 

 

o

Audio input CH15

Audio input (CH15)

–10 dBv 51 k, unbalanced

 

 

 

 

!0

Audio input CH16

Audio input (CH16)

–10 dBv 51 k, unbalanced

 

 

 

 

!1

(Signal GND)

 

 

 

 

 

 

!2

Alarm 1 Output (COMMON)

Common output 1

1 A, 30 V DC max.

 

 

 

 

!3

Alarm 1 Output (NO)

Output 1, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

!4

Alarm 1 Output (NC)

Output 1, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

!5

Alarm 2 Output (COMMON)

Common output 2

1 A, 30 V DC max.

 

 

 

 

!6

Alarm 2 Output (NO)

Output 2, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

!7

Alarm 2 Output (NC)

Output 2, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

!8

Alarm 3 Output (COMMON)

Common output 3

1 A, 30 V DC max.

 

 

 

 

!9

Alarm 3 Output (NO)

Output 3, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

@0

Alarm 3 Output (NC)

Output 3, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

@1

Alarm 4 Output (COMMON)

Common output 4

1 A, 30 V DC max.

 

 

 

 

@2

Alarm 4 Output (NO)

Output 4, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

@3

Alarm 4 Output (NC)

Output 4, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

@4

(Signal GND)

 

 

 

 

 

 

@5

+12 V

+12 V output

800 mA max.

 

 

 

 

49

Image 49
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Important Notice for U.S. fileds only Class 1 Laser ProductLimitation of liability Disclaimer of warrantyImportant safety instructions Contents Precautions Product disposal/transfer CleaningIndication label MPEG-4 Visual patent portfolio licensePreface FeaturesVarious Recording Functions Trademarks and registered trademarks About these operating instructionsFront View Major operating controls and their functions5Set button SET 4Escape button ESC6Stop button Stop 7Play/Pause button PLAY/PAUSERear View Connect the provided power cord to this inlet 7Power cord inlet ACExample When displaying images from camera channel When displaying images on a 16-split screenImage display 040000PMStart up the recorder as follows StartupDisplay the setup menu by pressing the Setup button Adjustment of the clock of the recorderSystem Setup window will be displayed Shutdown of the recorder When playing recorded images, stop playbackTo shut down the recorder, do the following Press the Stop buttonMonitor live images from the cameras Available functions when displaying live imagesDisplay images on a single screen Display images from cameras on a multi-screenSequential display on a 4-split screen Sequential display on a single screenAlarm recording Timer recordingRecording Manual recordingPlayback Available functions when playing imagesFast forward playback/Fast reverse playback Skip playback PausingFrame by frame forward playback Frame by frame reverse playbackCamera No Search and playStart Searched Search and play with multiple search filtersStart/End FilteringSearch result window will be displayed Action at an event occurrence alarm action Alarm functionRecords alarm logs Cancel the alarm actionStarts recording automatically Alarm recording Display the Copy window by pressing the Copy button Copying DuplicateCopy List window will be displayed Log out Log in as a different userUser Management window will be displayed Operation restriction differences between the user levels LogDisk management Maintenance window will be displayedCheck HDD information Disk Management window will be displayedUsed CapacityHour Meter Format only the selected HDD Format the HDDFormat all the HDDs Display the Disk Management windowWhen completing the HDD replacement, press the SET button Stop power supply to the HDDDisk Management window will be displayed again Since the replace HDD is unformatted yet, format the HDDRestore HDD management information Functions and their descriptions Operate the recorder using a PCSystem requirements for a PC HDD safety mode InstallationInstallation When completing the installation, press the SET buttonHDD addition HDD replacementRack mounting Basic connection ConnectionRS485 cable WV-CA48/50 Connection with RS485 camerasConnection with PS·Data systems When connecting a single unit with a controllerDIP switches Connect the recorder and a PC directly Connection with a PCAdd the recorder to the existing network Add the recorder to a broadband WAN Wide Area Network Operation Accessible numberOFF Pin No Signal Operation Remark Audio IN/ALARM OUT terminalRS485 Camera port Alarm IN/CONTROL terminal Setup menu chart Setup menuBasic operation of the setup menu Configure the system settings System Setup Default Off Summer Time DST Auto Adjust TimeDefault Off Summer Time DST Table Default Search TimeConfigure the common recording settings Common Setup Configure the recording settings Recording SetupDefault 4 Sec Resolution Advanced SetupDefault Field Time Per FileConfigure the timer recording settings Timer Rec. Setup Configure the manual recording settings Manual Rec. SetupAlarm Buzz Configure the alarm action settings Event SetupDefault On Alarm Spot Default OnConfigure the alarm recording settings Alarm Rec. Setup Default 030 sec Alarm Duration VMD Area Setup Set the VMD areaAlarm Output Port Alarm Spot Camera NoDefault All Configure the display settings Display SetupCamera Allocation Setup Status DisplayProtocol TypeCompensation Configure the network settings Network Setup Configure the PS·Data settings PS.Data Setup Configure the RS485 settings RS485 SetupDefault 1 bit Retry Timing Default None Stop BitAlarm Data Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Refer to page 31 for how to log out of the recorder Set the password PasswordLogout of the recorder Logout Check the alarm log Alarm Log Maintenance functions MaintenanceCheck the Error Log Error Log Check the system information System Information Current Temperature Highest TemperatureManage the HDDs Disk Management Following can be checkedReboot the recorder Reboot System Reset the current settings to the default Factory DefaultFollowing information will be displayed for Type MonitorTC YYYY-MM-DD Hhmmss Restore Default Settings User number 1 20, a Auto Login UserAccess Log Check the detailed information Advanced InformationFirmware Update OperationWJ-RT416 WV-CU650 Operation using the system controllerPlay Available only when the search window isStop playback Fast forward/slow playbackSymptom Troubleshooting13, 49 58-60 Symptom General SpecificationsInput/Output FunctionRecording time length Standard accessoriesFor business users in the European Union Panasonic System Solutions CompanyPanasonic Canada Inc Panasonic Sales Company