Symptom
The recorder starts up in the HDD safety mode when turning on the power.
Cannot start recording.
Cannot play recorded images.
Cannot operate the camera.
No alarm action is taken.
No notification mail is sent.
The clock does not keep cor- rect time.
It takes some time to start play- back after the search.
Cause/solution
•The recorder always starts up in the HDD safety mode when the power is turned on. This is not malfunction.
•Check if the HDD has any available disk space.
•Check the schedule settings.
•Is this user allowed to play recorded images?
Check the user level setting of the user who is currently logged in.
•Check the connection of the camera to be operated. Coaxial communication control is available for the cameras connected to the VIDEO IN 1 to 4 connectors.
•Check if the camera to be controlled is a combination cam- era.
•Check the camera control settings.
•Check if alarm output signals are properly input to the AUDIO IN/ALARM OUT or ALARM IN/CONTROL terminal on the rear of the recorder.
•Check the settings for "Event Setup".
•When alarms occurred sequentially for a long period, notifi- cation mail of a new alarm occurrence may not be sent.
•Check if the
•The hard disk in which the images to be played are stored may be in the
Reference
pages
39
33, 34
57
32
43
–
62
13, 49, 50
58-60
–
–
–
76