Panasonic WJ-RT416V manual Standard accessories, Recording time length

Page 79

Standard accessories

CD-ROM*

1 pc.

Installation Guide (this book)

1 pc.

Warranty (only for NTSC model)

1 set

* The following are included on the CD-ROM.

 

• Operating instructions of the monitoring software (PDF)

 

• Monitoring software (RT4Client)

 

The following is for installation.

 

Power cable for NTSC model

1 pc.

Power cable for PAL model

2 pcs.

HDD mounting screw, sleeve, damper for the WJ-RT416K

24 pcs. each

HDD mounting screw, sleeve, damper for the WJ-RT416

20 pcs. each

HDD mounting screw, sleeve, damper for the WJ-RT416VK

20 pcs. each

HDD mounting screw, sleeve, damper for the WJ-RT416V

16 pcs. each

Rack mounting brackets

2 pcs.

Fixing screw for rack mounting brackets

8 pcs.

Recording time length

Approximate possible recording time length (days) is as follows.

Possible recording time length varies depending on object of shooting.

Camera channel: 16 channels

Audio: Off

I Frame Interval: 4 (Default)

Resolution: Field

 

 

 

Rec. Duration: 10 hours/day

Rec. Duration: 24 hours/day

 

 

 

 

 

 

 

 

 

 

 

 

Rec. Frame Rate

Rec. Quality

 

HDD capacity

 

 

HDD capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500 GB*1

 

1000 GB*2

 

1500 GB*3

500 GB*1

 

1000 GB*2

 

1500 GB*3

 

 

SP Fine

3.0

 

6.0

 

9.0

1.2

 

2.5

 

3.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full

Fine

3.7

 

7.3

 

11

1.5

 

3.1

 

4.6

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

4.7

 

9.4

 

14

2.0

 

3.9

 

5.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extended

6.6

 

13

 

19

2.7

 

5.5

 

8.2

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Consisted of two 250 GB HDDs

 

 

 

 

 

 

 

 

 

 

*2

Consisted of four 250 GB HDDs

 

 

 

 

 

 

 

 

 

 

*3

Consisted of six 250 GB HDDs

 

 

 

 

 

 

 

 

 

 

79

Image 79
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Important Notice for U.S. fileds only Class 1 Laser ProductLimitation of liability Disclaimer of warrantyImportant safety instructions Contents Precautions MPEG-4 Visual patent portfolio license CleaningProduct disposal/transfer Indication labelPreface FeaturesVarious Recording Functions Trademarks and registered trademarks About these operating instructionsFront View Major operating controls and their functions7Play/Pause button PLAY/PAUSE 4Escape button ESC5Set button SET 6Stop button StopRear View Connect the provided power cord to this inlet 7Power cord inlet AC040000PM When displaying images on a 16-split screenExample When displaying images from camera channel Image displayStart up the recorder as follows StartupDisplay the setup menu by pressing the Setup button Adjustment of the clock of the recorderSystem Setup window will be displayed Press the Stop button When playing recorded images, stop playbackShutdown of the recorder To shut down the recorder, do the followingDisplay images from cameras on a multi-screen Available functions when displaying live imagesMonitor live images from the cameras Display images on a single screenSequential display on a 4-split screen Sequential display on a single screenManual recording Timer recordingAlarm recording RecordingPlayback Available functions when playing imagesFast forward playback/Fast reverse playback Frame by frame reverse playback PausingSkip playback Frame by frame forward playbackCamera No Search and playStart Filtering Search and play with multiple search filtersSearched Start/EndSearch result window will be displayed Action at an event occurrence alarm action Alarm functionRecords alarm logs Cancel the alarm actionStarts recording automatically Alarm recording Display the Copy window by pressing the Copy button Copying DuplicateCopy List window will be displayed Log out Log in as a different userUser Management window will be displayed Operation restriction differences between the user levels LogDisk Management window will be displayed Maintenance window will be displayedDisk management Check HDD informationUsed CapacityHour Meter Display the Disk Management window Format the HDDFormat only the selected HDD Format all the HDDsSince the replace HDD is unformatted yet, format the HDD Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Disk Management window will be displayed againRestore HDD management information Functions and their descriptions Operate the recorder using a PCSystem requirements for a PC When completing the installation, press the SET button InstallationHDD safety mode InstallationHDD addition HDD replacementRack mounting Basic connection ConnectionRS485 cable WV-CA48/50 Connection with RS485 camerasConnection with PS·Data systems When connecting a single unit with a controllerDIP switches Connect the recorder and a PC directly Connection with a PCAdd the recorder to the existing network Add the recorder to a broadband WAN Wide Area Network Operation Accessible numberOFF Pin No Signal Operation Remark Audio IN/ALARM OUT terminalRS485 Camera port Alarm IN/CONTROL terminal Setup menu chart Setup menuBasic operation of the setup menu Configure the system settings System Setup Default Search Time Auto Adjust TimeDefault Off Summer Time DST Default Off Summer Time DST TableConfigure the common recording settings Common Setup Configure the recording settings Recording SetupTime Per File Advanced SetupDefault 4 Sec Resolution Default FieldConfigure the timer recording settings Timer Rec. Setup Configure the manual recording settings Manual Rec. SetupDefault On Configure the alarm action settings Event SetupAlarm Buzz Default On Alarm SpotConfigure the alarm recording settings Alarm Rec. Setup Alarm Spot Camera No VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Output PortStatus Display Configure the display settings Display SetupDefault All Camera Allocation SetupProtocol TypeCompensation Configure the network settings Network Setup Configure the PS·Data settings PS.Data Setup Configure the RS485 settings RS485 SetupDefault 1 s Camera Number Setup Default None Stop BitDefault 1 bit Retry Timing Alarm DataRestrict the operable functions User Level Setup Refer to page 31 for how to log out of the recorder Set the password PasswordLogout of the recorder Logout Check the alarm log Alarm Log Maintenance functions MaintenanceCheck the Error Log Error Log Following can be checked Current Temperature Highest TemperatureCheck the system information System Information Manage the HDDs Disk ManagementMonitor Reset the current settings to the default Factory DefaultReboot the recorder Reboot System Following information will be displayed for TypeCheck the detailed information Advanced Information User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Access LogFirmware Update OperationWJ-RT416 WV-CU650 Operation using the system controllerFast forward/slow playback Available only when the search window isPlay Stop playbackSymptom Troubleshooting13, 49 58-60 Symptom Function SpecificationsGeneral Input/OutputRecording time length Standard accessoriesPanasonic Sales Company Panasonic System Solutions CompanyFor business users in the European Union Panasonic Canada Inc