■Advanced Setup
The following window will be displayed when the [SET] but- ton is pressed after moving the cursor onto "Set→".
Network Setup (Advanced)
DNS | Off |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
IP Address (Primary) |
| . |
| |||||
|
|
|
|
|
|
| ||
IP Address (Secondary) |
| . |
| |||||
|
|
|
|
|
| |||
Server Port | 02000 |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| OK |
|
|
|
|
| Cancel |
■DNS
Select "Manual" or "Auto" to enable IP address searching by the host name using the DNS.
Select "Off" when not using the DNS.
Selecting "Auto" is available only when "On" is selected for "DHCP" (using the DHCP server).
When "Manual" is selected for the DNS, enter the DNS serv- er addresses in "IP Address (Primary)" and "IP Address (Secondary)".
Enter 4 units from the decimal numbers
Default: Off
Server Port
Set the server port number of the recorder (required to use the monitoring software).
1 - 65535 Default: 2000
w Configure the RS485 settings [RS485 Setup]
Configure the RS485 settings.
RS485 Setup
Baud Rate |
| 19200 |
| |
|
|
|
| |
Data Bit | 8 |
| ||
Parity |
|
| None | |
Stop Bit | 1 |
| ||
|
|
|
|
|
OK |
|
| Cancel |
■Baud Rate
Select a line speed for data communication with the con- nected device from the following.
2 400/4 800/9 600/19 200/38 400 (bps) Default: 19 200 (bps)
■Data Bit
The data bit will be displayed. It is impossible to change the value.
■Parity
A method of checking for errors in communication function- ing will be displayed. It is impossible to change the value.
■Stop Bit
The stop bit type will be displayed. It is impossible to change the value.
e Configure the PS·Data settings [PS.Data
Setup]
Configure the PS·Data settings.
| PS.Data Setup |
|
|
| |||
|
|
|
|
|
|
|
|
Unit Address(System) |
| 001 |
|
| |||
|
|
|
|
|
|
| |
Unit Address(Controller) | 002 |
|
| ||||
|
|
|
|
|
|
|
|
Baud Rate |
| 9600 |
| ||||
Data Bit |
| 8 |
|
| |||
|
|
|
|
|
|
|
|
Parity |
| None |
| ||||
|
|
|
|
|
|
|
|
Stop Bit |
| 1 |
|
| |||
|
|
|
|
|
|
|
|
Retry Timing |
| Off |
| ||||
|
|
|
|
|
|
|
|
Alarm Data |
| 1s |
| ||||
|
|
|
|
|
|
|
|
Camera Number Setup |
| Set |
| ||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| OK |
|
| Cancel |
|
| |
|
|
|
|
|
|
|
|
■ Unit Address (System)
A unit address (Sys) is a unique number assigning to PS·Data devices. The addresses must be unique to identify system devices when connecting multiple devices compatible with PS·Data.
Numbers,
Default: 001
■Unit Address (Controller)
A unit address (Ctrl) is a unit address assigning to con- trol PS·Data devices. Numbers,
64