Panasonic WJ-RT416V manual Capacity, Used, Hour Meter

Page 34

Notes:

The used disk space will not be displayed as "0 GB" even when no data is saved on the disk since the sys- tem uses some of the disk space.

HDD6 is not provided for the WJ-RT416V.

Capacity

The total size of the HDD will be displayed.

Used

The used size of the HDD will be displayed.

Hour Meter

The hour meter of the HDD will be displayed.

Note:

When a HDD is in the faulty state, the indication will dis- played on the "Disk Management" window as follows. No Disk Detected: Indicates that no HDD is connect-

ed.

Disk Unformatted: Indicates that the HDD is not for- matted with this recorder.

Disk Access Error: Indicates that a HDD access error occurred.

Data Error: Indicates that the directory structure of the HDD is broken.

Disk Unacknowledged: Indicates that the recorder failed to mount the HDD for a reason such as data number limitation, even though the HDD is in the normal state.

Disk Type Unfitting: Indicates that the model number and the disk size of the newly mounted HDD is dif- ferent from the replaced HDD.

Screenshot 4

The "Disk Information" window will be displayed.

 

Disk Information

 

Oldest

Latest

HDD1:01-01-2006 10:00:00

01-31-2006 09:45:00

HDD2:01-31-2006 10:00:00

02-28-2006

09:45:00

HDD3:02-28-2006

10:00:00

03-31-2006

09:45:00

HDD4:03-31-2006

10:00:00

04-30-2006

09:45:00

HDD5:

 

No Data

 

 

HDD6:

 

No Data

 

 

 

 

 

 

 

 

 

Close

 

 

 

 

 

 

 

Step 4

Move the cursor onto "Information", and then press the [SET] button.

Step 5

Check time and date of the oldest data and the latest data, and then press the [SET] button.

34

Image 34
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Class 1 Laser Product Important Notice for U.S. fileds onlyDisclaimer of warranty Limitation of liabilityImportant safety instructions Contents Precautions Indication label CleaningProduct disposal/transfer MPEG-4 Visual patent portfolio licensePreface FeaturesVarious Recording Functions About these operating instructions Trademarks and registered trademarksMajor operating controls and their functions Front View6Stop button Stop 4Escape button ESC5Set button SET 7Play/Pause button PLAY/PAUSERear View 7Power cord inlet AC Connect the provided power cord to this inletImage display When displaying images on a 16-split screenExample When displaying images from camera channel 040000PMStartup Start up the recorder as followsDisplay the setup menu by pressing the Setup button Adjustment of the clock of the recorderSystem Setup window will be displayed To shut down the recorder, do the following When playing recorded images, stop playbackShutdown of the recorder Press the Stop buttonDisplay images on a single screen Available functions when displaying live imagesMonitor live images from the cameras Display images from cameras on a multi-screenSequential display on a single screen Sequential display on a 4-split screenRecording Timer recordingAlarm recording Manual recordingPlayback Available functions when playing imagesFast forward playback/Fast reverse playback Frame by frame forward playback PausingSkip playback Frame by frame reverse playbackCamera No Search and playStart Start/End Search and play with multiple search filtersSearched FilteringSearch result window will be displayed Alarm function Action at an event occurrence alarm actionRecords alarm logs Cancel the alarm actionStarts recording automatically Alarm recording Copying Duplicate Display the Copy window by pressing the Copy buttonCopy List window will be displayed Log out Log in as a different userUser Management window will be displayed Log Operation restriction differences between the user levelsCheck HDD information Maintenance window will be displayedDisk management Disk Management window will be displayedUsed CapacityHour Meter Format all the HDDs Format the HDDFormat only the selected HDD Display the Disk Management windowDisk Management window will be displayed again Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Since the replace HDD is unformatted yet, format the HDDRestore HDD management information Functions and their descriptions Operate the recorder using a PCSystem requirements for a PC Installation InstallationHDD safety mode When completing the installation, press the SET buttonHDD replacement HDD additionRack mounting Connection Basic connectionConnection with RS485 cameras RS485 cable WV-CA48/50When connecting a single unit with a controller Connection with PS·Data systemsDIP switches Connect the recorder and a PC directly Connection with a PCAdd the recorder to the existing network Operation Accessible number Add the recorder to a broadband WAN Wide Area NetworkOFF Pin No Signal Operation Remark Audio IN/ALARM OUT terminalRS485 Camera port Alarm IN/CONTROL terminal Setup menu Setup menu chartBasic operation of the setup menu Configure the system settings System Setup Default Off Summer Time DST Table Auto Adjust TimeDefault Off Summer Time DST Default Search TimeConfigure the recording settings Recording Setup Configure the common recording settings Common SetupDefault Field Advanced SetupDefault 4 Sec Resolution Time Per FileConfigure the manual recording settings Manual Rec. Setup Configure the timer recording settings Timer Rec. SetupDefault On Alarm Spot Configure the alarm action settings Event SetupAlarm Buzz Default OnConfigure the alarm recording settings Alarm Rec. Setup Alarm Output Port VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Spot Camera NoCamera Allocation Setup Configure the display settings Display SetupDefault All Status DisplayProtocol TypeCompensation Configure the network settings Network Setup Configure the RS485 settings RS485 Setup Configure the PS·Data settings PS.Data SetupAlarm Data Default None Stop BitDefault 1 bit Retry Timing Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Refer to page 31 for how to log out of the recorder Set the password PasswordLogout of the recorder Logout Check the alarm log Alarm Log Maintenance functions MaintenanceCheck the Error Log Error Log Manage the HDDs Disk Management Current Temperature Highest TemperatureCheck the system information System Information Following can be checkedFollowing information will be displayed for Type Reset the current settings to the default Factory DefaultReboot the recorder Reboot System MonitorAccess Log User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Check the detailed information Advanced InformationFirmware Update Operation using the system controller OperationWJ-RT416 WV-CU650Stop playback Available only when the search window isPlay Fast forward/slow playbackTroubleshooting Symptom13, 49 58-60 Symptom Input/Output SpecificationsGeneral FunctionStandard accessories Recording time lengthPanasonic Canada Inc Panasonic System Solutions CompanyFor business users in the European Union Panasonic Sales Company